![F&F CRT-06 Manual Download Page 5](http://html.mh-extra.com/html/fandf/crt-06/crt-06_manual_534584005.webp)
Example of change parameter value.
OK
OK
OK
OK
OK
OK
Tryb
MENU
Settings
MENU
Tryb
MENU
Temp.T1
Set
Tryb
MENU
+ 0°
Temp.T1
Tryb
MENU
+ 60°
Temp.T1
Tryb
MENU
+ 60°
Saved
OK
OK
Tryb
MENU
Settings
MENU
OK
OK
Tryb
MENU
Temp.T1
Settings
Tryb
MENU
Temp.T2
Settings
Tryb
MENU
Temp.T3
Settings
Tryb
MENU
Temp.T4
Settings
Tryb
MENU
Hyst.T1
Settings
Tryb
MENU
Hyst.T2
Settings
MENU
Settings
MENU
Settings
Delay T1
MENU
Settings
Tryb
MENU
Cor.CT1
Settings
Tryb
MENU
Cor.CT2
Settings
Distinction
Delay T2
ATTENTION:
Edition of setting is possible for parameter which
are use ina executigram. When need to change parameter which
isn’t use in program then option will not able.
ATTENTION:
Settings which were able to program, are present
under ( numbers aren’t cross out):
Ordered value of temperature T1
Temperature could be set in range: -100÷400°C
with precision 1°C.
ATTENTION!!: Possible is quick change value of
ordered temperature T1 and T2 without pass to
menu-> settings. You need in standard work push
button OK. It cause display actual value. Next by
buttons “UP” or “DOWN” set new value and enter by
OK. If need edit next temperature push button OK.
Push a button return cause out from edition mode
without save all changes.
1
2
3
4
5
6
7
8
9
10
Tryb
MENU
Temp.T1
Settings
Ordered value of temperature T2.
Te m p e r a t u r e c o u l d b e s e t i n r a n g e
-100÷400°C with precision 1°C.
Ordered value of temperature T3.
Te m p e r a t u r e c o u l d b e s e t i n r a n g e
-100÷400°C with precision 1°C.
Ordered value of temperature T4.
Te m p e r a t u r e c o u l d b e s e t i n r a n g e
-100÷400°C with precision 1°C.
Value of hysteresis for temperature T1.
Te m p e r a t u r e c o u l d b e s e t i n r a n g e
1÷100°C with precision 1°C.
Value of hysteresis for temperature T2.
Te m p e r a t u r e c o u l d b e s e t i n r a n g e
1÷100°C with precision 1°C.
Ordered distiction of temeratures which is use as
parameter prog 7.
Distiction of temperaturs could be set in range
1÷500°C with precision 1°C.
1
1
1
1
1
1
2
2
2
2
2
2
3
3
3
3
3
3
4
4
4
4
4
4
5
5
5
5
5
5
6
6
6
6
6
6
7
7
7
7
7
7
8
8
8
8
8
8
9
9
9
9
9
9
10
10
10
10
10
10
Tryb
MENU
Temp.T2
Settings
Tryb
MENU
Temp.T3
Settings
Tryb
MENU
Temp.T4
Settings
Tryb
MENU
Hyst.T1
Settings
Tryb
MENU
Hyst.T2
Settings
MENU
Settings
Distiction
Minimal time to hold a one position (ON or OFF) of
retay output
Parameter DelayT2 is dependent from sensor C2.
Example of work for prog 1 with delay . Delay was
present in earlier point.
Correction of sensor reports C1.
Sensor reprts could be corrected by ±20°C with
precision 1°C.
Minimal time to execute one cycle of program (ON
or OFF)
Parameter DelayT1 is dependent from sensor C1.
Example of work for prog 1 with delay . Delay is
present on under picture..
1
1
1
2
2
2
3
3
3
4
4
4
5
5
5
6
6
6
7
7
7
8
8
8
9
9
9
10
10
10
MENU
Settings
MENU
Settings
Tryb
MENU
Cor.CT1
Settings
P1
P2
C1
T
1
T - H
1
1
T + H
1
1
Delay
Delay
Delay
Delay T1
Delay T2