PURPOSE

The CRT-06 controller is multi-function, programmable electronic 
devices  which  enable  control  of  heating  or  cooling  devices  in 
order to maintain a stable room temperature, as well as to control 
ambient  and  substance  temperatures  in  industrial  conditions, 
with the option of supervising technological processes. 

CRT-06

CRT-06

www.fif.com.pl

ul. Konstantynowska 79/81

tel/fax 48 42 2270971 POLAND

e-mail: [email protected]

95-200 Pabianice

F&F products are covered by an 24 months warranty from date of purchase

DIGITAL TEMPERATURE 

REGULATOR

   

DESCRIPTION OF CONTROL PANEL:

To  work  and  programming  of  regulator  CRT-06  is  use  control 
panel. It include two line with eight sign on alfanumerical display 
and  keyboard  with  five  buttons,  which  is  situated  under  the 
display.

In  standard  work  mode  on  display  are  present  values  of   
temperaturer  which  are  measure  by  sensors  C1  and  C2.  If  is 
connect only one sensors- C1, then  at  place on display for reprts 
from  C2 anything is diplaied. 

Signs on the left side of display,  signalize work mode of regulator 
in position of output relay. This sign present:

In programming mode button Return   make possible to 
return main menu. If button will be push at edition mode, 

then  program  return  to  main  menu  without  save  all 
registry.  Button  Return  enable  to  delete  information 

abaut errors.

BUTTONS FUNCTIONS:

L1
L2
L3

CRT

N

N

L

CONTROLLERS FEATURES:

- controlling panel use for programming and monitor to work of 
regulator
- possibilty of connection two independent temperature probes 
PT-100
- two outputs of relay 1P which were attribute to sensors

- control panel for programming and monitoring;
- 10 operation functions;
- 2 independent temperature sensors;
- two independent temperature values may be set;
- 2 x 1P contacts applied to the temperature sensors;
- 2 hysteresis set values, one for each sensor;
- AUTOMATIC mode - operation with one selected function;
- MANUAL mode   permanent closing or opening of the contact 
without  a  temperature  measurement.  Separate  temperature 
drops for the P1 and P2 contacts.
- memory feature for maximum and minimum temperature values 
registered, independent for the C1 and C2 sensors;
-  CORRECTION    related  to  the  temperature  read-out  error 
against the model thermometer;
-  WARNING  -  visual  signalisation  of  the  temperature  sensor 
failure, range exceed and speed riasing or falling   temperature 
exceed
- limiting access to program menu using PIN code
- LIGHT  selection of display illumination mode.
- LANGUAGE program menu in three languages: Polish, English 
or Russian

CRT-05 is equipped to:

CRT-05

OK

OK

Menu

Menu

 +125şC

 +97şC

Two liness, 

with eight sign

alfanumeric

display 

Controll

buttons

At programming mode buttons UP and DOWN make to 
possibility to select position of menu and to increase or 
reduce value of edited parameter.

In programming system mode button OK  enable to pass  
to selected position from menu and enter the changes.
In  standard  work  button  OK  is  use  to  change  order 
temparature T1 and T2 .

Button  Menu  enable  to  pass  to  programming  mode  of 
regulator.
In change order value mode use it cause reconnection 
between setting for first and secon sensor.

OK

OK

Menu

Menu

5 9 0 8 3 1 2

5 9 2 7 1 6

 +125º

 +97º

Reprts from 
sensor C1

Reprts from 
sensor C1

Position of output

 realy P1

Position of output

 realy  P2

Open joint - automatic work mode 

Open joint - manual work mode 

Close joint - automatic work mode 

Close joint - manula work mode 

Summary of Contents for CRT-06

Page 1: ... panel for programming and monitoring 10 operation functions 2 independent temperature sensors two independent temperature values may be set 2 x 1Pcontacts applied to the temperature sensors 2 hysteresis set values one for each sensor AUTOMATIC mode operation with one selected function MANUAL mode permanent closing or opening of the contact without a temperature measurement Separate temperature dr...

Page 2: ...et of output relays independent of reports from sensors 5 In automatic work will dispalied menu to select program one of tenth saved in device memory OK OK Menu Menu Info MENU System MENU Settings MENU Tryb MENU Mode MENU ATTENTION Choose handwork mode is signalize by sign R near sings which present position of relays P1 ON joint of relay P1 is close but joint of relay P2 is open P1P2 ON joints of...

Page 3: ...nited temperature T2 and hysteresis threshold H2 T1 T1 H1 T1 H1 P1 P2 C1 Relays P1 and P2 works alternately P1 work in cooling mode closing joint when teperature fall under value T1 H1 and opening it when cross value T1 H1 Realy P2 work in heating mode closing joint when temperature fall under value T1 H1 and returnly opening it when cross value T1 H1 P1 P2 T1 T2 T1 H1 T2 H2 C1 T1 H1 T2 H2 C2 PROG...

Page 4: ...ow mode two sensors Regulator works with two sensors C1 and C2 If temperature from two sensors will be in range which is definited by values T1 iandT2 then relay joints P1 and P2 will be closed C1 P1 P2 T1 T2 ATTENTION When will set value T2 T1 then regulator will be work correct PROG 10 Window mode two regulators Device works as two independent thermostats which works in window mode Sensor Czujni...

Page 5: ...cision 1 C Ordered value of temperature T3 Te m p e r a t u r e c o u l d b e s e t i n r a n g e 100 400 C with precision 1 C Ordered value of temperature T4 Te m p e r a t u r e c o u l d b e s e t i n r a n g e 100 400 C with precision 1 C Value of hysteresis for temperature T1 Te m p e r a t u r e c o u l d b e s e t i n r a n g e 1 100 C with precision 1 C Value of hysteresis for temperature ...

Page 6: ...OK Menu Menu Menu Menu ATTENTION Work in safe mode is signalize by dispalied a sign In this cause pass to setting of regulator press button MENU is previuos by key correct a pin code Example of key PIN code 6 System Password This parameter is use to safe acces for all user to menu Password is a number from range 0 to 999 but save password to 0 unlock a menu Set password another than 0 cause pass t...

Page 7: ...t NO Default sett YES Saved YES ATTENTION Return to default settings cause delete all earlier configurations with saved programs Rest of parameters of regulators are set with values Menu Info This Menu Info is use to display max and min values which were registered by temperature sensor OK OK Hi 54 Lo 23 Info MENU Code 01 Error Code 02 Error Error codes Wrong work of regulator is siganalize by bli...

Page 8: ...ll cause break contolled device or menace for user In this cause producer is not responsible of arise accidents and could refuse given warranty for regulator in cause submit a claim A090706 sensor PT100 dimensions of sensor Ø4 h 85mm sensor isolation steel bush cable PC 3 0 34mm l 1 5m PROBE RT56 TECHNICAL DATA supply 230V AC current load 2 16A joint separated 1P range of regulation temperature 10...

Page 9: ...01 0100 10 120 TCN4L 22R TX4H 14R TX4H 24R TX4H A4R TX4H B4R TX4L 14R TX4L A4R TX4L B4R TX4M 14R TX4M 24R TX4M A4R TX4M B4R QP99 CP 02 CP82 CP99 R38 LAOO R38 LARR 72 11304023 0150 0050 72 11304027 0150 0050 72 23304003 0150 0050 GGP 72 23904001 0300 0040 TM 72 34904001 0300 0040 TM TEM 73 A AT403 414 1000 AT403 614 1000 AT 503 1141 000 AT 503 1161 000 AT 503 6140 000 AT 603 1141 000 AT603 414 1000...

Reviews: