The relay has the feature of the so-called „memory” of the con-

tact position, which means when the power supply is switched 

back on, the relay will be restored to the state it was in when the 

power supply was switched off.

The "LED" version of the relay is equipped with a contact 

designed to cooperate with receivers with high starting 

current, such as: LED fluorescent lamps, ESL fluorescent 

lamps, electronic transformers, discharge lamps, etc.

1. Disconnect the power supply.

2. Fix the relay on a rail in the control box.

3. Connect the power wires to terminals 1-3, any polarity for AC 

voltage and for DC voltage: connect „+” to terminal 3, „–” to 

terminal 1.

4. Momentary switches connected in parallel connect to terminal 

6 and the wire, to which terminal 3 is connected.

5. Powered receiver connect in series to terminals 11-12.

6. Set the switch-off time with the potentiometer.

BIS-413M-LED 24V is not compatible with backlit but-

tons.

Mounting

Contact configuration

Summary of Contents for BIS-413M-LED

Page 1: ...llumination of the green LED marked as U Switching the relay on and the countdown to automatic switch off is signalled by the blinking of the red LED Permanent switching of the relay is signalled by continuous lighting of the red LED Purpose Functioning F F Filipowski sp j Konstantynowska 79 81 95 200 Pabianice POLAND phone fax 48 42 215 23 83 48 42 227 09 71 www fif com pl e mail biuro fif com pl...

Page 2: ... ESL fluorescent lamps electronic transformers discharge lamps etc 1 Disconnect the power supply 2 Fix the relay on a rail in the control box 3 Connect the power wires to terminals 1 3 any polarity for AC voltage and for DC voltage connect to terminal 3 to terminal 1 4 Momentary switches connected in parallel connect to terminal 6 and the wire to which terminal 3 is connected 5 Powered receiver co...

Page 3: ... 3 1 3 relay power supply 9 30 V AC DC 6 control input 11 12 NO contact active Wiring diagram ...

Page 4: ...lay 0 1 0 2 s adjustment time 1 12 min power indication green LED signalling activation red LED power consumption standby 0 15 W on 0 8 W terminal 2 5mm screw terminals tightening torque 0 4 Nm working temperature 25 50 C dimensions 1 module 18 mm mounting on TH 35 rail ingress protection IP20 Technical data ...

Page 5: ...t www fif com pl The F F products are covered by a warranty of the 24 months from the date of purchase Effective only with proof of purchase Contact your dealer or directly with us F F Filipowski sp j declares that the device is in conformity with the essential requirements of The Low Voltage Directive LVD 2014 35 EU and the Electromagnetic Compatibility EMC Directive 2014 30 UE The CE Declaration...

Page 6: ......

Reviews: