Lumina 41/42
Clocks, external registration and alarms
29
The extra clock can be used to switch external equipment. One extra clock can be used per house.
Installer
CLOCK / REGIS.
WATER
Description
Setting of the name of the function.
Time clock type
Setting indicating how the user can use the clock:
ON/OFF
: User enters on/off times.
ON/DURATION
: User enters time and duration of activation.
Time clock relay
Setting for the analog output address (choice
LINEAR
) or relay output (choice
RELAY
).
Relay type
Setting of the passive (not controlled) relay status.
N.O.
(normally open) if it makes no contact.
N.C.
(normally closed) if it makes contact.
Per house, the control computer has an input that can be used to register water consumption.
The amount is registered in the form of pulse values (counts) or contact. The control computer adds up the
number of counts or measures the active time and converts the time into a measured amount. Enter in the
registration menu per house how the measured data can be read in.
Installer
CLOCK / REGIS.
REGISTRATION
Depending on the registration input type one of the following menus will appear:
Description
Setting of the name of the function.
Input Addr.
Setting of the address of the digital input.
Summary of Contents for LUMINA 41
Page 1: ...g ...
Page 39: ...Lumina 41 42 Technical specifications 35 ...
Page 41: ...Lumina 41 42 Technical specifications 37 ...
Page 44: ...Lumina 41 42 Appendix Concept feeding systems 40 ...
Page 46: ...Lumina 41 42 Appendix Concept feeding systems 42 ...
Page 47: ...Lumina 41 42 Appendix Concept feeding systems 43 ...
Page 48: ...Lumina 41 42 Appendix Concept feeding systems 44 ...
Page 50: ...Lumina 41 42 Appendix Concept feeding systems 46 ...