Gnd
10
g
In
automatic mode
, the meanings of the indications are:
Display
indication
Meaning
0.
Idle position, waiting for a change in the control value or feedback.
1.
Motor sends closed.
2.
Motor sends open.
3.
Waiting position after turning on (when controlled via 0-10V).
4.
Waiting position after turning on (when controlled via and I own network; duration is dependent
on the address).
5.
Minimum waiting position after a sending action.
6.
Idle position in which the control is determined by the remote control.
7.
Motor is standing still against a limiting switch.
U.
Due to problems, the iM.60 now controls based on the predefined position.
L.
Due to the I/O network going down, the iM.60 now runs independently based on its own
temperature measurements.
The flashing dot on the display indicates that the intelligent module is functioning normally and is getting
power from a regular 24 V AC source.
Adjustment is only possible if the operation switch is not in the automatic (
A
) position.
When applying a 0-10V/10-0V connection between the iM.60 and the regulator, the appropriate voltage
must be provided during the adjustment procedure for the open and closed position.
Ensure that the steel cable is always wrapped around the drum at least one complete turn when the air
inlet is completely open.
The minimum rotation from open to closed must be a minimum of 0.7 revolutions.
The minimum difference between the open and closed
voltage must be 2.2 V.