Fancom 743
5. Function keys
14
RunT
Enter the run time for this preparation action in hours, minutes and seconds.
End
The calculated end time for this preparation action. The computer calculates
this value using the entered start and run times.
Amount
The readout between brackets depends on the set form of preparation: with
register the value 0 is always shown; with dose the amount of feed the
computer will prepare during this preparation action will be shown; with
distribute the amount of feed the computer will prepare today. Following the
brackets is the amount of feed already prepared for the current preparation
action.
Status
The preparation action status. There are four possibilities:
FREE
Status must be FREE in order to prepare feed. This refers to an
active feed action.
BLOCKED The computer will not activate this preparation action as long as
status is BLOCKED.
SKIP
The computer will skip this preparation action for this day. When
the run time has elapsed the computer will automatically reset
the setting to FREE.
ONCE
After a feed action the status will be BLOCKED again.
B.rhythm
An animal’s feeding pattern is not constant throughout the day. The feed
amount can be adjusted per preparation action. If a negative percentage (e.g.
-5%) is entered, the computer will prepare 5% less feed during this action. A
positive percentage (e.g. +5%), means that 5% more feed will be prepared. The
amount originally to have been prepared during this action will be shown
between brackets. The sum of the biorhythm percentages must be 0!
Prep. time
The amount of time required for this preparation action.
AddI/II ...
from ...
A maximum of two additives can be added per preparation action. Select here
which additives and from which ingredient onwards they should be added by
the computer.
Amount
The calculated amount of additive to be added by the computer during this
preparation action.
Copy to all
storage silos?
Set to YES to copy all settings made for this storage silo to the other storage
silos.