Two post hydraulic lift QJY3.0-E
13
6 Maintenance
Authorized personnel only!
Turn off and lock the main switch before servicing the lift.
The maintenance intervals indicated below apply to average workshop use.
The lift should be inspected more frequently for severe use applications
6.1 Maintenance schedule
Establish a periodic preventive maintenance procedure to ensure trouble free operation and long
service life.
Interval
Maintenance to be performed on
Items
1 week
Support arms/Disk adapters
l
Check rubber pads for wear
l
Check arm restraints for engagement
Greasing points
Check and lubricate as required:
l
Slide tracks
l
Arm extensions
l
Threads of disk adapters
6 months
Nuts of anchor bolts
Check all nuts for correct torque and retighten
them as required
12 months Hydraulic system
l
Check fluid level.
l
Check tightness of hoses and fittings.
6.2 Annual inspection
We recommend having the lift inspected by qualified service personnel every 12 months.
6.3 Maintenance by the operator
6.3.1 Hydraulic system
l
Checking the Fluid Level
The fluid level can be read through the transparent reservoir at the power unit.
With the lift fully lowered, the fluid level must reach above the min level.
l
Once a year check the fluid level with the lift fully lowered and add fluid as required.
l
Visually check all hydraulic hoses for tightness.
The hydraulic fluid must be replaced periodically depending on aging, soiling and
water absorption. It is recommended to replace the pressure hoses as required, but
after six years at the latest.