Family inada HCP-27D Operating Manual Download Page 11

[Manual Selection Mode]

[Manual Selection Mode]

19

20

4

Manual Selection Mode

How To Operate Manual Selection Mode

How To Adjust Each

To stop in the middle of a massage, push the POWER button on the remote to bring the rollers back to storage 

position and end the massage action.

In an emergency or if some malfunction occurs, use the STOP button to stop the chair immediately. After confirming 

safety, press POWER button. Rollers stop after going back to storage position. 

Changing from Manual Selection Mode to a Healthcare Program

If you press Healthcare Program button during Manual Selection Program with remote control panel closed, rollers 

once go back to storage position to start with automatic Shiatsu Point locating and Healthcare Program. 

Changing Programs

Stopping in the Middle of a Massage

2

1

3

Use the buttons to select your 
desired massage.

Press POWER button.

Flip open panel on remote control to show 
Manual Selection buttons.
If no selection is made within five minutes, 
the power automatically shuts off.

The rollers return to storage position 
(upper part of seat back).

The massage action is 
completed in 15 minutes.

Operation is complete.

 If you feel the massaging action too strong, reduce the stimulation according to this Operating Man-

ual. If this solution does not work, stop using and contact the store where you purchased the chair.

May result in injury if constantly used on a high stimulation level. 

 Do not place hands or feet into the roller tracks or into the space between the seat back 

and the seat or into moving parts. Do not sit wearing hard object like hair accessories.

 If your leg or foot gets out of the foot rest during the massage, don't try to force it back in.

Forward

Kneading, Human Touch, Kneading & 
Tapping: Buttons toggle among 

FORWARD

BACKWARD

, and 

STOP

.

Backward

Massaging speed can be adjusted with either FAST or 
SLOW button in a phase manner during Kneading, 
Kneading & Tapping, or Tapping 1 action. 
Speed can also be changed during the massage.

Adjust  air  massage  intensity  on  foot,  calf,  and 
seat  respectively.  Button  toggles  among 

Me-

dium

High

, and 

Low

.

Adjusts back massage intensity at any level. 

Speed

Left display shows when Kneading action 

speed has been set at 4.

Speed levels:

Keading

6 levels (Speed 1 to 6)

Kneading & Tapping, Tapping 1

4 levels (Speed 1 to 4)

Roller width can be adjusted among 3 "Narrow", 

"Medium", or "Wide" during Rhythm Shiatu 1, Tap-

ping 1/2, Full/Partial Roller, or Back Vibration action. 
Width can also be changed during the massage

* However, this function is not available if action which 

does not allow width adjustment like Kneading, Human 
Touch, Kneading & Tapping, Rhythm Shiatsu2 is com-
bined with Roller or Back Vibration. 

Display

Action

Button

Display

Description

Action

Display

Description

Action

Button

Description

Action

Button

Narrow

Medium

Wide

Width

* Center of Partial Roller range can be adjusted in Partial Roller mode. 

When using Full Roller Massage, the UP and DOWN buttons will 
change the direction of the rollers.

Up/Down

Moves roller position to desired with this 
button during Keading, Human Touch, 
Keading & Tapping, Rhythm Shiatsu 1/2, 
Manual Shiatsu 1/2, Tapping 1/2, Partial 
Roller, or Back Vibration action.

 Width Adjustment Buttons

 SPEED ADJUSTMENT Buttons

 UP DOWN Adjustment Buttons

 Toggling between FORWARD and BACKWARD direction

 Air Pressure Adjustment Buttons

 Intensity Buttons

You can change programs without waiting for the selected program to finish.

In this case, timer would be reset, but massaging action is to stop once 30 minutes later, rated duration. 

Caution

Summary of Contents for inada HCP-27D

Page 1: ...nute to maximum 650 times minute 3 levels narrow medium and wide One full cycle top to bottom and top again in approx 20 seconds About 64 cm in partial roller massage about 15 cm Healthcare Programs 8 types with automatic Shiatsu Point Locator function 20 types some include automatic Shiatsu Point Locator function 2 types Foot and Back Toggles between 2 levels of intensity for each location Air pr...

Page 2: ...ident or electrical shock Contact the store where you purchased the chair for repairs l Do not place fingers or objects in between the footrest units in between the footrest and the chair Be careful not to get hands caught when raising the footrest by hand l Do not use the chair with wet body or wet hands Could result in injury or electrical shock l Be sure that there is nobody especially children...

Page 3: ...ation level l Be sure to keep the back pad in place during massage Do not use the chair without the back pad May result in personal injury l Try not to fall asleep in the chair during a massage May result in personal injury l Keep massage sessions to no more than 15 minutes in length Area Specific Massage of any partic ular area on the body to no more than 5 minutes Continual use for extended peri...

Page 4: ...or Plug Wheels Seat Armrest Foot Unit Control Box Reclining Safety Mechanism Power Connector Main POWER Switch Storage roller position is inside the upper part of the seat back Foot Vibrator Seat Air Cushion Seat Vibrator Thigh Air Cushion Calf Air Cushion Ankle Air Cushion Top of the Foot Air Cushion Foot Air Cushion Remote Control Stand Remote Control Rollers ...

Page 5: ... vibration during healthcare pro gram BGM Button Plays 15 minutes of background music or bird song sounds through the speaker Press again to stop Background music can sometimes be cut out by other audio messages Background music can be played whenever the main POW ER switch on the chair is ON even if the remote control is not turned on l Do not sit or step on the remote control Do not drop the re ...

Page 6: ...ch as bath rooms or saunas l Only install on a flat level surface l Do not use in areas of high debris or dust content Do not use where ambient temperature is 40 C or over l Do not install chair where it can come into contact with direct heat such as direct sunlight or radiator Caution If the rollers have stopped in mid massage turning the main POWER switch ON again will reset the rollers to Start...

Page 7: ...ates whenever the reclining function is used When the chair stops reclining the footrest also stops moving Then the foot slide function automatically ex tends or shortens the footrest to match the length of your legs l Foot slide automatic adjustment function becomes available when you release Reclining Button l After the foot slide stops you can further adjust the footrest position using the Foot...

Page 8: ...all and large are provided for use with the chair Use them to keep your head in a comfortable natural position during your massage l The small head rest pad is attached to the chair with velcro so it can be moved about Move the small head rest to match the height of your head before starting the massage There is a buffer pad thin located behind the back pad that helps absorb some of the roller sti...

Page 9: ...Back Tension Legs Hips Fatigue Shiatsu Healthcare Programs Manual Selection Mode 1 2 3 4 5 Morning Night Time Seat 6 7 8 l Duration of each course varies depending on height body type reclining angle and other factors of users Recommended to the person who has low energy or is easy to get tired 15 minutes approx Focused massage on the neck and shoulders 13 minutes approx Focused massage on the low...

Page 10: ...Vibration Though Shiatsu Point is located for limit focused massaging neck shoulders and lower back and Roller in Manual Selection Mode like Healthcare Program shoulder position cannot be adjusted immediately following Only Normal Roller can be combined with Manual Shiatsu for both Full and Partial Area Specific Massage neck shoulders and lower back cannot be chosen in combination with Roller Forw...

Page 11: ...don t try to force it back in Forward Kneading Human Touch Kneading Tapping Buttons toggle among FORWARD BACKWARD and STOP Backward Massaging speed can be adjusted with either FAST or SLOW button in a phase manner during Kneading Kneading Tapping or Tapping 1 action Speed can also be changed during the massage Adjust air massage intensity on foot calf and seat respectively Button toggles among Me ...

Page 12: ...ressing one of the Healthcare Pro gram buttons LEGS Omits leg for air massage with one touch of LEGS button Press again to resume SEAT Omits forearm and upper arm for air massage with one touch of SEAT button Press again to resume BACK You can see that back is excluded for massaging on remote control display once BACK button is pressed To cancel press BACK under MASSAGE CANCEL again If nothing is ...

Page 13: ...WER is on Select the desired air pressure setting from among the saved settings 1 4 2 Press SAVE button 1 Adjust the air pressure for each of the air cushions to the most comfortable level Selected air pressure setting is displayed 3 Choose 1 4 from the Personal Memory buttons Confirms that the selected settings have been saved Confirms that air pressure settings are being saved Recalls the saved ...

Page 14: ...rest adjusting function is not working properly The footrest is not touching the bottoms of my feet Sit further back in the chair so your head rests firmly on the seat back Healthcare Pro grams allow you to make adjustments to the shoulder position with the Shoulder Position Adjustment button after the Shiatsu Point Locator function has completed The footrest adjusting function is not working prop...

Page 15: ...a damp cloth that has been soaked in warm water and a mild detergent and then thoroughly wrung out to clean any spots or grime Storage After wiping off any dust or dirt store your chair in a place that is relatively dry If you are not going to use the chair for some time put a cover on it that will protect it from dust and dirt Pets can sometimes chew on power cords so try to keep pets away from t...

Page 16: ...ephone number 2 Name of product and model number see back cover of this manual 3 Serial number see the company sticker on the control box on back of the chair 4 Date of purchase 5 Problem you are experiencing in as much detail as possible Under warranty Have your warranty card ready Even under warranty some repairs will be charged for so please read the card carefully Warranty expired Contact the ...