FAMILY INADA HCP-i2A Operating Manual Download Page 10

MASSAGE

POWER

TIMER

min.

MANUAL SELECTION MODE

On the manual selection mode, some programs can be 
turned on with one push and can be cancelled by pressing 
the same button again. Others will go through three steps: 
rotation, reverse rotation, and off (The above illustration 
shows a course for "Kneading, forward" and "speed, 3"). 
The liquid crystal display (small) displays the name of the 
course selected for three seconds and then displays the 
relevant icons (shown on pages 17 and 18). The liquid 
crystal display (large) displays some information on the 
course selected, as well as the remaining time of operation.

The display will light up. To make a selection from the 

Manual Selection Mode, open the external panel on 

the remote control. If no buttons are pressed within five 

minutes, the power will automatically turn off.

MANUAL SELECTION MODE

The operation will stop, and 
the display will automatically 
turn off.

The rollers will return to the home (storage) 

position.

To cancel the program during its operation, press 

the Power switch. The program will end after the 

rollers return to the home (storage) position.

Manual Selection Modes     /Operation

2

Table showing the massage types which can be combined, and the items which are adjustable.

Table of illustrations displayed

You can select the desired massage type from the massage menu from 1 to 5. You can also make combinations among them.

Adjustable items during operation will be marked 

(circle).

Rollers and back vibration are not adjustable if you combine those with Kneading, Human Touch, Double Kneading, Kneading & Tapping 

or Rhythm Shiatsu 2.

1

Standard program

 (select any one of the massage adjustments)

 

Kneading

 

Human Touch

 

Double Kneading

 

Kneading & Tapping

 

Rhythm Shiatsu 1

 

Rhythm Shiatsu 2

 

Tapping 1

 

Tapping 2

Massage adjustment

 

○ 

○ 

ー 

○ 

ー 

ー 

ー 

ー 

Speed adjustment

 

 

Speed 1

6

6 levels

 

ー 

ー 

 

Speed 1

4

4 levels

 

ー 

ー 

 

Speed 1

4

4 levels

 

ー 

Width adjustment

 

ー 

ー 

ー 

ー 

 

Narrow

Medium

Wide

3 levels

 

ー 

 

Narrow

Medium

Wide

3 levels

 

 

Narrow

Medium

Wide

3 levels

Vertical position adjustment

 

○ 

○ 

○ 

○ 

○ 

○ 

○ 

○ 

Intensity

 

ー 

ー 

ー 

ー 

ー 

ー 

ー 

ー 

5

Lower body air massage

 (select any one of the massage adjustments)

 

Legs

Seat

Legs & Seat

 

ー 

ー 

ー 

Speed adjustment

 

ー 

ー 

ー 

Width adjustment

 

ー 

ー 

ー 

Vertical position adjustment

 

ー 

ー 

ー 

Intensity

 

 

Low

Medium

High

 

Low

Medium

High

 

Low

Medium

High

2

Rollers

 (select any one of the massage adjustments)

 

Roller (Whole)

Roller (Partial)

Roller types

Air massage

 

ー 

ー 

Speed adjustment

 

ー 

ー 

Width adjustment

 

 

Narrow

Medium

Wide

3 levels

 

 

Narrow

Medium

Wide

3 levels

 

 

Vertical position adjustment

 

 

Up/Down movement     

 

Adjustment of center position

Intensity

 

ー 

ー 

3

Back vibration

 

Back vibration

 

ー 

Speed adjustment

 

ー 

Width adjustment

 

 

Narrow

Medium

Wide

3 levels

Vertical position adjustment

 

○ 

Intensity

 

 

Low

High

4

Seat vibration

 

Seat vibration

 

ー 

Speed adjustment

 

ー 

Width adjustment

 

ー 

Vertical position adjustment

 

ー 

Intensity

 

 

Low

High

Plus

Plus

Plus

Plus

Massage type

Displayed icon

Rhythm Shiatsu 1

Kneading & Tapping

Double Kneading

Human Touch

Massage type

Displayed icon

Normal rotation

Reverse rotation

Tapping 2

Tapping 1

Massage type

Displayed icon

Roller (Partial)

Back vibration

Roller (Whole)

Narrow

Wide

Medium

Changing Programs

You can switch to other massage types anytime, 

even during the operation of a program. However, 

the timer will be reset.

Manual Selection Mode to preset program

During any operation of the Manual Selection Mode, if you 

select a preset program on the external panel/door, the rollers 

will return to the home position. The function for automatically 

detecting massage points will then start. The preset program 

selected will start after this.

Course/program

Roller width

Massage type

Displayed icon

Massage type

Displayed icon

Lower body
 (Legs)

High

High

Low

Low

Seat vibration

Lower body
 (Legs & Seat)

High

Medium

Low

High

Lower body
 (Seat)

During the Manual Selection Mode, the operating 
status is displayed by the relevant icons.

Massage Type

Direction of rotation (normal or reverse)

Speed

Roller

Roller width

Back vibration (intensity)

Seat vibration (intensity)

Lower body massage (intensity)

Back vibration

Low

Rhythm Shiatsu 2

Low

Medium

Medium

High

Kneading

Speed

Manual Selection Modes     /Operation

2

Manual Selection Modes     /Operation

2

Press Power 
button.

Press the 
button of 
the desired 
program.

The operation will 
automatically 
end 15 minutes 
after starting.

Normal rotation/

Reverse rotation

Massage adjustment

Normal rotation/

Reverse rotation

Massage adjustment

Normal rotation/

Reverse rotation

Massage adjustment

Normal rotation/

Reverse rotation

Massage adjustment

Normal rotation/

Reverse rotation

*These programs can be combined with the armrest vibration feature.

Summary of Contents for HCP-i2A

Page 1: ...ting Adjustable range Approx 4 inches Power recline to any position between approx 120 and 170 degrees Upright 29 W 47 L 45 H Reclined 29 W 68 L 29 H Remote control Remote control stand 7 West 56th Street Technical assistance 10 00 17 00 Eastern Standard Time Closed Saturday Sunday and Public Holidays Inada Chair i 2 2A Model number Power frequency Width between rollers Back stroke range Preset Ai...

Page 2: ...ost professional like massage techniques FAMILY INADA INC is a U S subsidiary of Japan s best selling luxury massage chair manufacturer FAMILY CO LTD Provides a hybrid massage function using roller pressure and air pressure Four rollers provide professional like techniques for massaging the upper half of the body Ten air cells provide a delicate massage for the lower half of the body A remote cont...

Page 3: ...ns with a history of vertigo fainting or tinnitus Do not use the chair with anything other than a 120 V power source May result in fire or electric shock Do not use with any type of transformer device May result in injury or electric shock Do not use if the power cord or outlet is damaged or if the power outlet is loose May result in electric shock short circuit or combustion Before each use check...

Page 4: ... to no more than 5 minutes Continual use for extended periods of time can result in over stimulation having the opposite of the desired effect or even injury Aim to have no more than 30 minutes total massage time per day Do not allow yourself to fall asleep in the chair during a massage May result in injury If your legs or feet fall out of the footrest during the air massage do not try to force th...

Page 5: ...e indicator and press ing the button again will turn off the indicator Adjusts the speed of Kneading Tapping 1 and Kneading Tap ping operations Adjusts the reclining angle Well Being Programs To prevent damage and malfunction do not sit on the remote control Do not step on or place any heavy objects on the remote control Do not pull on the remote control wire STOP button Use this button to shut th...

Page 6: ...th how to manually turn off the power after use to prevent an accidental start of the chair Place the chair at least 3 feet away from a TV radio or other AV equipment It may cause noise in the equipment Attach the stand to the right armrest of main body using the screw included as shown in the figure Press and hold the reclining button labeled DOWN until the desired angle is obtained Press and hol...

Page 7: ......

Page 8: ...roximate time of operation remaining actual time left may vary slightly If you wish to stop the program during the operation press the Power switch The rollers will then return to the home position and the program will stop The display will light up To select a preset program close the external panel on the remote control If no buttons are pushed for five minutes the power will automatically turn ...

Page 9: ...width between rollers and vertical position are adjustable The width between rollers and their vertical position are adjustable The width between rollers and their vertical position are adjustable The direction of the roller rotation the speed and the vertical position are adjustable The direction of the roller rotation the speed and the vertical position are adjustable The direction of roller rot...

Page 10: ...tment ー ー ー Intensity Low Medium High Low Medium High Low Medium High 2 Rollers select any one of the massage adjustments Roller Whole Roller Partial Roller types Air massage ー ー Speed adjustment ー ー Width adjustment Narrow Medium Wide 3 levels Narrow Medium Wide 3 levels Vertical position adjustment Up Down movement Adjustment of center position Intensity ー ー 3 Back vibration Back vibration ー Spe...

Page 11: ...t and a damp cloth Wipe with a dry cloth next to dry the surface of the chair Caution Caution Long contact with vinyl plastic material or wallpaper may cause discoloration Back pad Headrest Covers 1 Undo the velcro that fixes the seat cover to the footrest bottom cover 2 Undo the 6 velcro strips that fix the seat cover to the seat and remove the seat cover To re attach the seat cover reverse the a...

Page 12: ...ally to prevent interfering with the body To continue the massage press the power button on the remote control again Keep your body at the deepest position in the chair and keep your head on the headrest The Automatic Massage Points Detection System will not function if the Manual Selection Mode is in operation You can adjust the width and vertical positions of the rollers using the buttons while ...

Page 13: ...0601 Attach the stand to the right armrest of the main body using the screw included as shown in the figure To remove the stand reverse the attachment procedure Armrest right side Screw Remote control stand ...