ENGLISH

The equipment can be used by children over the age 
of 8 and by persons with reduced physical, sensory and 
mental abilities, or with no experience or knowledge, 
as long as they do so under supervision or after having 
received relative instructions regarding safe use of the 
equipment and understanding of the dangers connec-
ted to it. Children are not to play with the equipment. 
Cleaning and maintenance by the user must not be car-
ried out by children without supervision.

USE AND CLEANING WARNINGS

Before cleaning or carrying out maintenance 

operations, disconnect the equipment by re-

moving the plug or switching off the main switch.

Do not use the hood with wet hands or bare feet.
Always check that all electrical parts (lights, extractor 
fan) are off when the equipment is not being used. 
The maximum overall weight of any objects placed 
or hung (if applicable) on the hood must not exceed 
1.5 Kg.
Always supervise the cooking process during the use of 
deep-fryers: Overheated oil can catch fire.
Do not leave open, unattended flames under the hood.
Do not prepare food over an open flame under the 
hood.
Never use the hood without the metal anti-grease filters: 
in this case, grease and dirt will deposit in the equipment 
and compromise its operation.
Accessible parts of the hood can be hot when used at 
the same time as the cooking appliances.
Do not carry out any cleaning operations when parts of 
the hood are still hot.
There can be a risk of fire if cleaning is not carried out 
according to the instructions and products indicated in 
this booklet.
Disconnect the main switch when the equipment is not 
used for long periods of time.

If other appliances that use gas or other fuels 

are being used at the same time (boiler, stove, 

fireplaces, etc.), make sure the room where the 

fumes are discharged is well-ventilated, in compli-

ance with the local regulations.

 INSTALLATION

  only intended for qualified personnel

Before installing the hood, carefully read the chapter 'SAFETY 
INSTRUCTIONS AND WARNINGS'.

TECHNICAL FEATURES

The technical specifications are exhibited on the labels located inside the hood.

POSITIONING

The minimum distance between the highest part of the cooking equip-
ment and the lowest part of the hood is indicated in the installation in-
structions. 

Generally, when the hood is placed over gas cookers, the distance must be at 
least 65 cm (25.6''). However, according of standard EN60335-2-31, the minimum 
distance between the cooker and lower part of the hood can be reduced to the 
quota reported in the installation instructions.
Should the instructions for the gas cooker specify a greater distance, this must 
be taken into consideration.
Do not install the hood outdoors and do not expose it to outdoor environment 
(rain, wind, etc.).

ELECTRICAL CONNECTION

(only intended for qualified personnel)

Disconnect the equipment from electrical mains power supply be-
fore carrying out any operations on the hood.
Ensure that the wires inside the hood are not disconnected or cut:

in the event of damage, contact your nearest Servicing Department.
Refer to qualified personnel for electrical connections.
Connection must be carried out in compliance with the provisions of law 
in force.

Before connecting the hood to the electrical mains power supply, check that:
•  voltage supply corresponds with what is reported on the data plate located 

inside the hood;

•  the electrical system is compliant and can withstand the load (see the tech-

nical specifications located inside the hood);

•  the power supply plug and cable do not come into contact with temperat-

ures exceeding 70 °C;

•  the power supply system is effectively and properly connected to earth in 

compliance with regulations in force;

•  the socket used to connect the hood is within reach.

In case of:
•  devices fitted with cables without a plug: the type of plug to use is a ''stand-

ardised'' one. The wires must be connected as follows: yellow-green for earth-
ing, blue for neutral and brown for the phase. The plug must be connected to 
an adequate safety socket.

•  fixed equipment not provided with a power supply cable and plug, or any 

other device that ensures disconnection from the electrical mains, with an 
opening gap of the contacts that enables total disconnection in overvoltage 
category III conditions.

  Said disconnection devices must be provided in the mains power supply in 

compliance with installation regulations.

The yellow/green earth cable must not be cut off by the switch.
The Manufacturer declines all responsibility for failure to comply with the safety 
regulations.

FUMES DISCHARGE

EXTERNAL EXHAUST HOOD (SUCTION)

In this version the fumes and vapours are discharged outside 
through the exhaust pipe.
To this end, the hood outlet fitting must be connected via a 
pipe, to an external output.

The outlet pipe must have:
•  a diameter not less than that of the hood fitting.
•  a slight slope downwards (drop) in the horizontal sections to prevent con-

densation from flowing back into the motor.

•  the minimum required number of bends.
•  the minimum required length to avoid vibrations and reduce the suction per-

formance of the hood.

  You are required to insulate the pipes if it passes through cold environments.
  In the presence of motors with 800m3/h or higher, a check valve is present to 

prevent external air flowing back.

Deviation for Germany:
when the kitchen hood is used at the same time as appliances that are powered by 
energy other than electricity, the negative pressure in the room must not exceed 4 Pa 
(4 x 10-5 bar).

HOOD WITH INTERNAL RECIRCULATION (FILTERING)

In this model, air passes through the active carbon filters HP (op-
tional) to be purified and is then recycled into the environment.
Ensure that the active carbon filters HP are assembled into the 
hood, if not, install them as indicated in the assembly instructions. 

Summary of Contents for ZENITH NRS

Page 1: ...TA LY IT LIBRETTO ISTRUZIONI EN INSTRUCTIONS BOOKLET DE GEBRAUCHSANWEISUNG FR MODE D EMPLOI ES MANUAL DE INSTRUCCIONES RU PL INSTRUKCJA OBS UGI NL HANDLEIDING PT MANUAL DE INSTRU ES DK BRUGSANIVSNINGE...

Page 2: ...2 800 m3 h 376 19 397 min 789 max 1234 Zenith 180 Zenith 120 347 121 326 37 631 max 566 400 250 400 1090 150 540 600 900 1200 1770 350 Zenith 90 8 mm ZENITH 90 50 KG ZENITH 120 56 KG ZENITH 180 68 KG...

Page 3: ...rtie lat rale utilisable uniquement avec faux plafond ES Salida lateral utilizable solo con falso techo RU PL Wylot boczny wykorzystywany tylko na sufitach podwieszanych NL Zijdelingse uitgang enkel b...

Page 4: ...ES INSTALACI N CON CIELO RASO RU PL MONTA NA SUFICIE PODWIESZANYM NL INSTALLATIE MET VALS PLAFOND PT INSTALA O COM REVESTIMENTO NOTETO DK INSTALLATION MED NEDH NGT LOFT SE MONTERING MED UNDERTAK FI AS...

Page 5: ...nstalaci n v lvula de no retorno D RU C D PL Operacje wst pne monta kratki dolnej do komory silnika C instalacja zaworu zwrotnego D NL Voorbereidende handelingen monteer het onderste raamwerk aan de k...

Page 6: ...n de la bride 1 et du treillis 2 3 ES INSTALACI N EN TECHO Fijaci n de la brida 1 y del bastidor 2 3 RU 1 2 3 PL MONTA NA SUFICIE Mocowanie ko nierza 1 i kraty 2 3 NL PLAFONDINSTALLATIE Bevestiging fl...

Page 7: ...FAUX PLAFOND Fixation du treillis 4 et de la bride 5 6 ES INSTALACI N CON CIELO RASO Fijaci n del bastidor 4 y de la brida 5 6 RU 4 5 6 PL MONTA NA SUFICIE PODWIESZANYM Mocowanie kraty 4 i ko nierza...

Page 8: ...llis 8 ES Fijaci n del tubo NRS en el motor 7 y fijaci n del motor en el basti dor 8 RU NRS 7 8 PL Mocowanie rury NRS do silnika 7 oraz mocowanie silnika do kraty 8 NL Bevestiging NRS buis aan motor 7...

Page 9: ...au treillis ES Fijaci n de la chimenea y extensi n hasta el bastidor RU PL Mocowanie komina i przed u enia do kraty NL Bevestiging schouw en verlengstuk aan schacht PT Fixa o chamin e extens o treli...

Page 10: ...de la console 11 ouverture de la trappe 12 ES Fijaci n de la repisa 11 apertura de la puerta 12 RU 11 12 PL Mocowanie p ki 11 otw r klapy 12 NL Bevestiging schap 11 opening deur 12 PT Fixa o da prate...

Page 11: ...hemin e 14 ES Conexiones el ctricas 13 y colocaci n de la chimenea 14 RU 13 14 PL Po czenia elektryczne 13 i ustawie nie komina 14 NL Elektrische aansluitingen 13 en plaat sing van de schouw 14 PT Lig...

Page 12: ...16 PL Zamkni cie klapy po czenia elektryczne 15 wsuni cie filtra 15 i uszczelki 16 NL Sluiting deur elektrische aansluitingen 15 invoeging filter 15 en pakking 16 PT Fecho da porta e liga es el trica...

Page 13: ...ants pour le support console ES Fijaci n de los tirantes para el soporte de la repisa RU PL Mocowanie ci g w do wspornika p ki NL Bevestiging trekstangen voor ondersteuning van het schap PT Fixa o tir...

Page 14: ...hetta po sta all interno della cappa La presa usata per il collega mento elettrico deve essere facilmente raggiungibile con l apparecchiatura installata in caso contrario pre vedere un interruttore ge...

Page 15: ...e istruzioni di montaggio In generale quando la cappa da cucina posta su un piano cottura a gas que sta distanza deve essere almeno 65 cm 25 6 Tuttavia sulla base della norma EN60335 2 31 la distanza...

Page 16: ...d presenti nei tasti Velocit 1 Velocit 2 Velocit 3 Velocit 4 led lampeggiante Riduzione velocit da 4 a 1 Accensione spegnimento luce TIMER Led rosso lampeggiante Autospegnimento dopo 15min La funzione...

Page 17: ...male forno domestico ad una temperatura di 200 C per circa 1 ora Attendere che il filtro si sia raffreddato prima di rimontarlo ILLUMINAZIONE La cappa dotata di illuminazione a led ad alta efficienza...

Page 18: ...is report ed on the identification plate located inside the hood The socket used to connect the installed equipment to the electrical power supply must be within reach other wise install a mains switc...

Page 19: ...ied personnel Disconnectthe equipmentfrom electricalmains power supply be fore carrying out any operations on the hood Ensure that the wires inside the hood are not disconnected or cut in the event of...

Page 20: ...DEFAULT CODE the procedure is to be carried out if the hood is disposed of sold or transferred Disconnect the power to the hood before starting the procedure In this version the check valve must not...

Page 21: ...ARBON AND ZEOLITE FILTERS OPTIONAL KACL 961 In normal use conditions we recommend regenerating the zeolite carbon filter every 9 months and replacing it after 18 months Simply place it in a domestic o...

Page 22: ...Die elektrische Anlage f r den Anschluss der Ab zugshaube muss den geltenden Normen ent sprechen und mit einem Erdungssystem ausgestattet sein das den Sicherheitsvorschriften des Installations landes...

Page 23: ...zkessel fen Kamine etc f r eine angemes sene vorschriftsm ige L ftung des Raumes sorgen in dem die Dunstabsaugung erfolgt INSTALLATION Dieser Abschnitt ist ausschlie lich qualifiziertem Personal vorbe...

Page 24: ...e nach 15 Minuten Betrieb einzustellen WELCHE GESCHWINDIGKEITSSTUFE SOLL GEW HLT WERDEN Geschwindigkeit 1 H lt die Luft bei geringem Stromverbrauch rein Geschwindigkeit 2 Wird f r normale Bedingungen...

Page 25: ...ist verboten F r die Metallteile siehe den vorigen Atbschnitt METALLFETTFILTER Deshalb wird empfohlen die Metallfilter h ufig zu reinigen mindestens ein Mal pro Monat indem sie ungef hr 1 Stunde lang...

Reviews: