background image

15

ENGLISH

Cherries Jubilee, Peppercorn Beef Flambe').

c) Clean ventilating fans frequently. Grease should 

not be allowed to accumulate on fan or filter.

d) Use proper pan size. Always use cookware ap-

propriate for the size of the surface element.

WARNING:TO REDUCE THE RISK OF INJURY TO 

PERSONS IN THE EVENT OF A RANGE TOP GREASE 

FIRE, OBSERVE THE FOLLOWING

a

:

a) SMOTHER FLAMES with a close-fitting lid, cook-

ie sheet, or metal tray, then turn off the burner. 

BE CAREFUL TO PREVENT BURNS. If the flames 

do not go out immediately, EVACUATE AND CALL 

THE FIRE DEPARTMENT.

b) NEVER PICK UP A FLAMING PAN – You may be 

burned.

c) DO NOT USE WATER, including wet dishcloths 

or towels – a violent steam explosion will result.

d) Use an extinguisher ONLY if:

1) You know you have a Class ABC extinguisher, 

and you already know how to operate it.

2) The fire is small and contained in the area 

where it started.

3) The fire department is being called.

4) You can fight the fire with your back to an exit.

Based on "Kitchen Firesafety Tips" published by 

NFPA.

Before cleaning or carrying out mainte-

nance operations, disconnect the equip-

ment by removing the plug or switching 

off the main switch.

Do not use the hood with wet hands or bare feet.

Always check that all electrical parts (lights, extractor 

fan) are off when the equipment is not being used. 

The maximum overall weight of any objects placed 

or hung (if applicable) on the hood must not exceed 

3lb 5 oz (1.5 Kg).

Always supervise the cooking process during the use 

of deep-fryers: Overheated oil can catch fire.

Do not leave open, unattended flames under the 

hood.

Do not prepare food over an open flame under the 

hood.

Never use the hood without the metal anti-grease 

filters: in this case, grease and dirt will deposit in the 

equipment and compromise its operation.

Accessible parts of the hood can be hot when used at 

the same time as the cooking appliances.

Do not carry out any cleaning operations when parts 

of the hood are still hot.

There can be a risk of fire if cleaning is not carried out 

according to the instructions and products indicated 

in this booklet.

Disconnect the main switch when the equipment is 

not used for long periods of time.

If other appliances that use gas or other fu-

els are being used at the same time (boiler, 

stove, fireplaces, etc.), make sure the room 

where the fumes are discharged is well-ven-

tilated, in compliance with the local regula-

tions.

 INSTALLATION

   only intended for qualified personnel

Before installing the hood, carefully read the chapter 'SA-

FETY INSTRUCTIONS AND WARNINGS'.

TECHNICAL FEATURES

The technical specifications are exhibited on the labels located inside 
the hood.

POSITIONING

The minimum distance between the highest part of the cooking 

equipment and the lowest part of the hood is indicated in the in-

stallation instructions. 

Do not install the hood outdoors and do not expose it to outdoor envi-
ronment (rain, wind, etc.).

ELECTRICAL CONNECTION

(only intended for qualified personnel)

Disconnect the equipment from electrical mains power 

supply before carrying out any operations on the hood.

Ensure that the wires inside the hood are not disconnected 

or cut:

in the event of damage, contact your nearest Servicing Depart-

ment.

Refer to qualified personnel for electrical connections.

Connection must be carried out in compliance with the provisions 

of law in force.

Before connecting the hood to the electrical mains power supply, 
check that:
•  voltage supply corresponds with what is reported on the data plate 

located inside the hood;

•  the electrical system is compliant and can withstand the load (see 

the technical specifications located inside the hood);

•  the power supply plug and cable do not come into contact with 

temperatures exceeding 158°F (70 °C);

•  the power supply system is effectively and properly connected to 

earth in compliance with regulations in force;

•  the socket used to connect the hood is within reach.
In case of:
•  devices fitted with cables without a plug: the type of plug to use is 

a ''standardised'' one. The wires must be connected as follows: yel-
low-green for earthing, blue for neutral and brown for the phase. The 
plug must be connected to an adequate safety socket.

•  fixed equipment not provided with a power supply cable and plug, 

or any other device that ensures disconnection from the electrical 
mains, with an opening gap of the contacts that enables total dis-
connection in overvoltage category III conditions.

  Said disconnection devices must be provided in the mains power 

supply in compliance with installation regulations.

The yellow/green earth cable must not be cut off by the switch.
The Manufacturer declines all responsibility for failure to comply with 
the safety regulations.

Summary of Contents for Polar FDPLR15W5SS-R

Page 1: ...Polar FDPLR15W5SS R wall FDPLR15I5SS R island INSTRUCTIONS BOOKLET EN MODE D EMPLOI FR MANUAL DE INSTRUCCIONES ES LIBRETTO ISTRUZIONI IT INSTRUCTIONS BOOKLET Design...

Page 2: ...111 7 mm 6 152 6 mm 152 6 mm 8x 2 8 8x6 mm 8 5 8 2 2 0 m m 1 5 6 0 316 mm 12 7 16 Posizione pulsantiera elettronica Diameter of fixing holes Position for electronic pushbutton panel 2 6 8 70 mm 1 1 8...

Page 3: ...m 32 7 8 835 mm 6 154 mm 4 7 16 113 mm 8 1 2 218 mm 6 5 8 170 mm POLAR WALL 51 lb 23 Kg 35 7 16 12 6 8 3 8 R10 m m 13 32 R10 mm 324 mm Tempered 23 5 8 600 mm 900 mm 12 2 8 310 mm 35 7 16 12 6 8 3 8 R1...

Page 4: ...4 max 28 2 8 max 720 mm 2 1 8 m m 8 1 2 min 19 11 16 min 500 mm 150 mm 5 15 16 POLAR WALL...

Page 5: ...sent document ES Medidas instalaci n La altura de montaje recomendada desde la su perficie de cocci n hasta el fondo de la campana se indica con una A en el dibujo siguiente Se recomienda instalar la...

Page 6: ...6 T V1 A 2 1 3 1 2 446 mm 18 3 8 113 mm 4 7 16 113 mm 4 7 16 8 V2 1 2 A 3 1 2 3 4 5 16 8 mm 1 4 6 mm EN tool required FR outil requis ES herramienta requerida IT Attrezzi necessari...

Page 7: ...valve installation 5 Hood fastening 6 7 8 9 FR Installation du clapet anti retour 5 Fixation de la hotte 6 7 8 9 ES Instalaci n de la v lvula antirretorno 5 Fijaci n de la campana 6 7 8 9 IT Installaz...

Page 8: ...8 150 mm 5 15 16 POLAR ISLAND x2 2 1 3 A B C...

Page 9: ...sent document ES Medidas instalaci n La altura de montaje recomendada desde la su perficie de cocci n hasta el fondo de la campana se indica con una A en el dibujo siguiente Se recomienda instalar la...

Page 10: ...10 8 mm 5 16 V1 C 1 2 3 M 4 C B G D x V2 1 2 3 4...

Page 11: ...tirer les filtres m talliques A monter les filtres au charbon actif B Branchements lec triques C ES Fijaci n de la campana 1 3 4 5 Instalaci n de la v lvula antirretorno 2 ISLAND WALL Quite los filtro...

Page 12: ...12 V3 V3 A 1 2 3 S C C 1 2 1 E V3 A B S 2 3 4 OPTIONAL...

Page 13: ...ective equipment e g Safety shoes and adopt prudent and proper conduct The installation kit screws and plugs supplied with the hood is only to be used on masonry walls in case of installation on walls...

Page 14: ...equence of failing to comply with the safety warnings indicated in this booklet It is imperative that this instructions booklet is kept together with the equipment for any future consultation If the e...

Page 15: ...t the same time boiler stove fireplaces etc make sure the room wherethefumesaredischargediswell ven tilated in compliance with the local regula tions INSTALLATION only intended for qualified personnel...

Page 16: ...ndensation from flowing back into the motor the minimum required number of bends the minimum required length to avoid vibrations and reduce the suction performance of the hood You are required to insu...

Page 17: ...n and off TIMER red LED flashing Auto switch off after 15 min The function deactivates red LED off if The TIMER key is pressed again The ON OFF key is pressed If the pushbutton panel is completely ina...

Page 18: ...product is WEEE i e Waste electrical and electronic equipment accordingly it must not be disposed of with regular unsorted waste i e with mixed household waste but it must be disposed of separately so...

Page 19: ...e et contacter le Reven deur Apr s son installation aucune r clamation ne sera accept e pour des d fauts esth tiques Pendant l installation toujours utiliser des quipe ments de protection individuelle...

Page 20: ...s espaces clos entre des murs des pla fonds ou dans des greniers des vides sanitaires ou des garages AVERTISSEMENT AFIN DE R DUIRE LE RISQUE D INCENDIE UTILISER UNIQUEMENT DES CONDUITS M TALLIQUES MIS...

Page 21: ...t et contenu dans la zone o il a d marr 3 Les pompiers ont t appel s 4 Vous pouvez vous d fendre contre le feu en tournant le dos une sortie a D apr s le guide Kitchen Firesafety Tips pu bli par la NF...

Page 22: ...curit ne sont pas respect es VACUATION DES FUM ES HOTTE VACUATION EXT RIEURE ASPIRANTE Dans cette version les fum es et les vapeurs sont en voy es vers l ext rieur travers un tuyau d vacuation cette...

Page 23: ...la vitesse de 4 1 Allumage extinction lumi re Pression br ve allume et teint la lumi re TIMER LED rouge clignotante Arr t automatique apr s 15 min La fonction se d sactive LED rouge teinte si Vous app...

Page 24: ...Le symbole de la poubelle barr e report sur l appareil en votre possession indique que le produit est un DEEE c est dire un D chet d rivant d quipements lectriques et lectroniques et par cons quent il...

Page 25: ...instalada no se aceptar ninguna recla maci n por defectos est ticos Durante la instalaci n utilice siempre equipos de protecci n personal ej calzado de protecci n contra accidentes y adopte comportami...

Page 26: ...aire adecuadamente aseg rese de canalizar el aire al exterior No ventile el aire de escape hacia otras zonas a trav s de paredes o techos o hacia ticos s tanos o garajes ATENCI N PARA REDUCIR EL RIESG...

Page 27: ...manos mojadas o los pies descalzos Controle siempre que todas las partes el ctricas lu ces aspirador est n apagadas cuando no se use el equipo El peso m ximo total de los posibles objetos coloca dos o...

Page 28: ...se mediante un tubo a una salida externa El tubo de salida debe tener un di metro no inferior al del racor de la campana una ligera inclinaci n hacia abajo ca da en los tramos horizontales para evitar...

Page 29: ...n de la velo cidad de 4 a 1 Encendido Apagado luz TIMER Led rojo intermitente Apagado autom tico tras 15 min La funci n se desactiva Led rojo apagado si Se presiona otra vez la tecla TIMER Se presion...

Page 30: ...ilustrados en la figura 12V 3 1 2 ELIMINACI N AL FINAL DE LA VIDA TIL El s mbolo del contenedor tachado que se encuentra en su equipo indica que el producto es un RAEE es decir un Resi duo de Aparatos...

Page 31: ...ezzi di pro tezione personale es scarpe antiinfortunistiche ed adottare comportamenti prudenti e corretti Il kit di fissaggio viti e tasselli fornito con la cappa utilizzabile unicamente su pareti in...

Page 32: ...di pulizia sullo stesso Il Costruttore declina ogni responsabilit per eventuali danni che possano direttamente o in direttamente essere causati a persone cose ed animali domestici conseguenti alla man...

Page 33: ...i filtri metallici anti grasso grasso e sporco in questo caso si depositereb bero nell apparecchio compromettendone il funzio namento Parti accessibili della cappa possono essere calde se utilizzate...

Page 34: ...luisca nel motore il numero minimo indispensabile di curve la lunghezza minima indispensabile per evitare vibrazioni e di ridurre la capacit aspirante della cappa E necessario isolare la tubazione se...

Page 35: ...altra volta il tasto TIMER Si preme il tasto ON OFF Se la pulsantiera completamente inattiva prima di contattare il servi zio di Assistenza tecnica togliere temporaneamente circa 5 l alimen tazione e...

Page 36: ...le Apparecchiature Elettriche ed Elettroniche e pertanto non deve essere gettato nella spazzatura indifferenziata cio insieme ai rifiuti urbani misti ma deve essere gestito separata mente cos da esser...

Page 37: ...37 NOTE NOTES...

Page 38: ...38 NOTE NOTES...

Page 39: ...39 NOTE NOTES...

Page 40: ...Falmec S p A via dell Artigianato 42 z i 31029 Vittorio Veneto Treviso Italy info falmec com falmec com Codice Code Matricola Serial Number Code 110033088 Ed 01 2022...

Reviews: