MAINTENANCE

Before cleaning or carrying out maintenance operations, 

disconnect the equipment by removing the plug or 

switching off the main switch.

Do not use detergents containing abrasive, acidic or corrosive 

substances or abrasive cloths.

Regular maintenance guarantees proper operation and performance 

over time.

Special attention is to be paid to the 

metal anti-grease filters 

: fre-

quent cleaning of the filters and their supports ensures that no flamma-

ble grease is accumulated.

CLEANING OF EXTERNAL SURFACES

You are advised to clean the external surfaces of the hood 

at least once 

every 15 days

 

to prevent oily substances and grease from sticking to 

them. To clean the brushed stainless steel hood, the Manufacturer rec-

ommends using "Magic Steel" wipes.

Alternatively 

and for all the other types of surfaces

, it can be cleaned 

using a damp cloth, slightly moistened with mild, liquid detergent or 

denatured alcohol.

Complete cleaning by rinsing well and drying with soft cloths. 

Do not use too much moisture or water around the push 

button control panel and lighting devices in order to pre-

vent humidity from reaching electronic parts.

The glass panels can only be cleaned with specific, non-corrosive or 

non-abrasive detergents using a soft cloth.

The Manufacturer declines all responsibility for failure to comply with 
these instructions.

CLEANING OF INTERNAL SURFACES

Do not clean electrical parts, or parts related to the motor 

inside the hood, with liquids or solvents.

For the internal metal parts, see the previous paragraph.

METAL ANTI-GREASE FILTERS

It is advised to 

frequently

 wash the metal filters (

at least once a 

month

) leaving them to soak in boiling water and cleaning solution for 

1 hour, taking care not to bend them.
Do not use corrosive, acid or alkaline detergents.
Rinse them well and wait for them to be completely dry before reas-
sembling them.
Washing in a dishwasher is permitted, however, it may cause the filter 
material to darken: to reduce the possibility of this problem from hap-
pening, use low-temperature washes (131°F / 55°C max.).
To extract and insert the metal anti-grease filters see the assembly in-
structions.

ACTIVE CARBON FILTERS

These filters retain the odours in the air that passes through them. The 
purified air is recirculated into the environment.
The active carbon filters must be replaced on average every 3-4 months 
under normal conditions of use.
See assembly instructions to replace the active carbon filters.

LIGHTING

The range hood is equipped with high efficiency, low consumption LED 
spotlights with an extremely long life-span under normal use conditions.
Should the LED spotlight need to be replaced, proceed as shown in 
the figure.

12V

3

1

2

 DISPOSAL AFTER END OF USEFUL LIFE

The crossed-out trash or refuse bin symbol on the appliance 

means that 

the product is WEEE

, i.e. 

Waste electrical and 

electronic equipment'', accordingly 

it must not be disposed 

of with regular unsorted waste

 (i.e. with ''mixed household waste''), 

but it must be disposed of separately so that it can undergo specific 

processing for its re-use, or a specific treatment, to remove and safely 

dispose of any substances that may be harmful to the environment and 

remove the raw materials that can be recycled. Proper disposal of these 

products contributes to saving valuable resources and avoid potential 

negative effects on personal health and the environment, which may 

be caused by inappropriate disposal of waste.

You are kindly asked to contact your local authorities for further infor-

mation regarding the designated waste collection points nearest to 

you. Penalties for improper disposal of such waste can be applied in 

compliance with national regulations.

INFORMATION ON DISPOSAL IN EUROPEAN UNION COUNTRIES

The EU WEEE Directive was implemented differently in each country, 

accordingly, if you wish to dispose of this appliance we suggest con-

tacting your local authorities or dealer to find out what the correct 

method of disposal is.

INFORMATION ON DISPOSAL IN NON-EUROPEAN UNION COUNTRIES

The crossed-out trash or refuse bin symbol is only valid in the European 

Union: if you wish to dispose of this appliance in other countries, we 

suggest contacting your local authorities or dealer to find out what the 

correct method of disposal is.

WARNING!

The Manufacturer reserves the right to make changes to the equip-

ment at any time and without prior notice. Printing, translation and 

reproduction, even partial, of this manual are bound by the Manufac-

turer's authorisation. 

Technical information, graphic representations and specifications in 

this manual are for information purposes and cannot be divulged.

This manual is written in Italian. The Manufacturer is not responsible for 

any transcription or translation errors.

Summary of Contents for FPMEX30W6SS-R

Page 1: ...TRUCTIONS BOOKLET Design INSTRUCTIONS BOOKLET EN MODE D EMPLOI FR MANUAL DE INSTRUCCIONES ES LIBRETTO ISTRUZIONI IT Mercurio Mercurio XL wall FPMER24W3SS FPMER30W3SS FPMER36W3SS FPMEX30W6SS R FPMEX36W6SS R ...

Page 2: ... 1 2 115 mm 2 3 8 60 mm ø 4 1 1 1 6 1 2 0 m m 2 15 16 75 mm 10 7 16 265 mm min 18 14 16 480 mm 6 11 16 171 mm ø 4 11 16 120 mm 2 3 8 60 mm 13 3 8 340 mm 12 11 16 322 mm MERCURIO 24 FPMER24W3SS 120V 60HZ 150W 30lb 14 kg EN cable length 5 0ft 1 5m FR longueur de câble 5 0ft 1 5m ES longueur de câble 5 0ft 1 5m IT lunghezza cavo 5 0ft 1 5m 280 cfm ...

Page 3: ... 2 115 mm 2 3 8 60 mm ø 4 1 1 1 6 1 2 0 m m 2 15 16 75 mm 10 7 16 265 mm min 18 14 16 480 mm 6 11 16 171 mm ø 4 11 16 120 mm 2 3 8 60 mm 13 3 8 340 mm 12 11 16 322 mm MERCURIO 30 FPMER30W3SS 120V 60HZ 150W 33lb 15 kg EN cable length 5 0ft 1 5m FR longueur de câble 5 0ft 1 5m ES longueur de câble 5 0ft 1 5m IT lunghezza cavo 5 0ft 1 5m 280 cfm ...

Page 4: ... 1 2 115 mm 2 3 8 60 mm ø 4 1 1 1 6 1 2 0 m m 2 15 16 75 mm 10 7 16 265 mm min 18 14 16 480 mm 6 11 16 171 mm ø 4 11 16 120 mm 2 3 8 60 mm 13 3 8 340 mm 12 11 16 322 mm MERCURIO 36 FPMER36W3SS 120V 60HZ 150W 35lb 16 kg EN cable length 5 0ft 1 5m FR longueur de câble 5 0ft 1 5m ES longueur de câble 5 0ft 1 5m IT lunghezza cavo 5 0ft 1 5m 280 cfm ...

Page 5: ...0 mm 4 1 2 115 mm 2 3 8 60 mm ø 5 7 8 150 mm min 23 5 8 600 mm 2 3 8 60 mm 13 3 8 340 mm 3 3 4 95mm 12 11 16 322 mm 27 mm 10 7 16 265 mm ø 5 7 8 1 5 0 m m MERCURIO XL 30 FPMEX30W6SS R 120V 60HZ 430W 31lb 14 kg EN cable length 5 0ft 1 5m FR longueur de câble 5 0ft 1 5m ES longueur de câble 5 0ft 1 5m IT lunghezza cavo 5 0ft 1 5m 600 cfm ...

Page 6: ...260 mm 4 1 2 115 mm 2 3 8 60 mm ø 5 7 8 150 mm min 23 5 8 600 mm 2 3 8 60 mm 13 3 8 340 mm 3 3 4 95mm 12 11 16 322 mm 27 mm 10 7 16 265 mm ø 5 7 8 1 5 0 m m MERCURIO XL 36 FPMEX36W6SS R 120V 60HZ 430W 35lb 16 kg EN cable length 5 0ft 1 5m FR longueur de câble 5 0ft 1 5m ES longueur de câble 5 0ft 1 5m IT lunghezza cavo 5 0ft 1 5m 600 cfm ...

Page 7: ...dies nationaux et locaux qui remplacent toutes les recommandations stipulées dans le présent document ES Medidas instalación La altura de montaje recomendada desde la su perficie de cocción hasta el fondo de la campana se indica con una A en el dibujo siguiente Se re comienda instalar la campana en este rango para optimizar el rendimiento Se recomienda no exce der 35 890mm para la dimensión A ya q...

Page 8: ...aspiration 3 ES Fijación de la campana 1 instalación de la válvula antirretorno 2 y montaje del tubo de aspiración 3 IT Fissaggio cappa 1 installazione valvola di non ritorno 2 e montaggio tubo d aspirazione 3 280 cfm 5 7 8 150 mm 600 cfm 4 7 8 122mm 3 V2 x2 3 EN Mandatory safety screws FR Vis de sécurité obligatoires ES Tornillos de seguridad obligatorios IT Viti di sicurezza obbligatorie ...

Page 9: ...9 G H 1 V3 x6 2 4 L H 1 4 ø 6 mm ø 6 ø 6 V4 x2 5 L H V5 x2 3 L 2 5 EN Flue assembly FR Montage de la cheminée ES Montaje de la chimenea IT Montaggio camino ...

Page 10: ...10 10 EN Optional filter assembly FR Montage du filtre en option ES Montaje del filtro opcional IT Montaggio filtro opzionale 3 2 1 6 1 2 2 7 ...

Page 11: ...kage and contact the dealer No claim can be made for aesthetic or cosmetic defects once it has been installed During installation always use personal protective equipment e g Safety shoes and adopt prudent and proper conduct The installation kit screws and plugs supplied with the hood is only to be used on masonry walls in case of installation on walls of a different material assess other installa...

Page 12: ...ed to another per son make sure that the booklet is also supplied so that the new user can be made aware of the hood s operation and relative warnings After the stainless steel hood has been installed it will need to be cleaned to remove any residues re maining from the protection adhesive as well as any grease and oil stains which if not removed can cause irreversible damage to the hood surface T...

Page 13: ...ere the fumes are discharged is well ventilated in compliance with the local regulations INSTALLATION Intended only for qualified personnel Before installing the hood carefully read the section SA FETY INSTRUCTIONS AND WARNINGS TECHNICAL FEATURES The technical specifications are exhibited on the labels located inside the hood POSITIONING The minimum distance between the highest part of the cooking...

Page 14: ...passes through the charcoal filters to be purified and recycled in the environment Ensure that the active carbon filters are assembled into the hood if not install them as indicated in the assem bly instructions In this version the check valve must not be assembled remove it if it is on the air outlet fitting of the motor ASSEMBLY INSTRUCTIONS Intended only for qualified personnel The hood can be ...

Page 15: ... the hood For further details refer to the MAINTENANCE section USE OF MECHANICAL PUSH BUTTON CONTROL PANEL MERCURIO 24 FPMER24W3SS OFF 1 2 3 Light on off OFF OFF button Press this button to switch the motor off 1 Button 1 Press this button button in to start or set the motor at minimum speed 2 Button 2 Press this button button in to start or set the motor at medium speed 3 Button 3 Press this butt...

Page 16: ...to the environment The active carbon filters must be replaced on average every 3 4 months under normal conditions of use See assembly instructions to replace the active carbon filters LIGHTING The range hood is equipped with high efficiency low consumption LED spotlights with an extremely long life span under normal use conditions Should the LED spotlight need to be replaced proceed as shown in th...

Page 17: ...llage d origine et contacter le Reven deur Après son installation aucune réclamation ne sera acceptée pour des défauts esthétiques Pendant l installation toujours utiliser des équipe ments de protection individuelle ex des chaussures de sécurité et adopter un comportement prudent et correct Le kit de fixation vis et chevilles fourni avec la hotte est utilisable uniquement sur des murs en maçonne r...

Page 18: ...d incendie et d évacuer correctement l air assurez vous de faire circuler l air à l extérieur Ne pas faire entrer l air évacué dans des espaces clos entre des murs des pla fonds ou dans des greniers des vides sanitaires ou des garages AVERTISSEMENT AFIN DE RÉDUIRE LE RISQUE D INCENDIE UTILISER UNIQUEMENT DES CONDUITS MÉTALLIQUES MISES EN GARDE POUR L UTILISATEUR Ces mises en garde ont été rédigées...

Page 19: ... éteindre le brûleur SOYEZ PRU DENT POUR ÉVITER LES BRÛLURES Si les flammes ne s éteignent pas immédiatement ÉVACUER ET APPELER LES POMPIERS b NE JAMAIS SAISIR UNE POÊLE ENFLAMMÉE Vous pourriez vous brûler c NE PAS UTILISER D EAU y compris des torchons ou des serviettes mouillés une violente explo sion de vapeur en résulterait d Utiliser un extincteur UNIQUEMENT si 1 Vous savez que vous avez un ex...

Page 20: ... bleu pour le neutre et le fil marron pour la phase La fiche doit être raccordée à une prise de sécurité adéquate appareil fixe dépourvu de câble d alimentation et de fiche ou d un autre dispositif qui assure la déconnexion du réseau avec une dis tance d ouverture des contacts permettant la déconnexion com plète dans les conditions de la catégorie de surtension III Ces dispositifs de déconnexion d...

Page 21: ...allument sans clignoter cela signifie que la configuration a été effectuée correctement FONCTIONNEMENT QUAND FAUT IL ALLUMER LA HOTTE Allumer la hotte au moins une minute avant de commencer à cuisiner pour canaliser les fumées et les vapeurs vers la surface d aspiration Au terme de la cuisson laisser la hotte en fonction jusqu à l aspiration complète de toutes les vapeurs et odeurs grâce à la fonc...

Page 22: ...yer les surfaces externes de la hotte au moins tous les 15 jours afin d éviter que les substances huileuses ou grasses ne puissent les attaquer Pour le nettoyage de la hotte réalisée en acier inox brossé le Fabricant conseille l utilisation des serviettes Magic Steel Sinon pour tous les autres types de surface le nettoyage doit être effectué en utilisant un chiffon humide légèrement imprégné d un ...

Page 23: ...incorrecte de ces déchets conformément à la législation nationale INFORMATIONS SUR L ÉLIMINATION DANS LES PAYS DE L UNION EUROPÉENNE La directive communautaire sur les appareils DEEE a été transposée en mode différent par chaque nation par conséquent si l on souhaite éli miner cet appareil nous conseillons de contacter les autorités locales ou le revendeur pour demander la méthode d élimination co...

Page 24: ...al y póngase en contacto con el revendedor Una vez instalada no se aceptará ninguna recla mación por defectos estéticos Durante la instalación utilice siempre equipos de protección personal ej calzado de protección contra accidentes y adopte comportamientos prudentes y correctos El kit de fijación tornillos tacos y abrazaderas que se entrega con la campana se puede usar solo en pare des de mampost...

Page 25: ...DUCIR EL RIESGO DE INCEN DIOS UTILICE ÚNICAMENTE CONDUCTOS METÁ LICOS ADVERTENCIAS PARA EL USUARIO Estas advertencias se han redactado para su seguridad y la del resto de personas le rogamos que lea atentamente este manual antes de instalar o de usar el aparato o realizar opera ciones de limpieza en el mismo El Fabricante declina toda responsabilidad por posibles daños que puedan ser provocados di...

Page 26: ...s espal das una salida a Basado en Kitchen Firesafety Tips publicado por NFPA Antes de realizar cualquier tipo de limpieza o de mantenimiento desconecte el equipo desenchufándolo o usando el interruptor gene ral No use la campana con las manos mojadas o los pies descalzos Controle siempre que todas las partes eléctricas lu ces aspirador estén apagadas cuando no se use el equipo El peso máximo tota...

Page 27: ...as normas de seguridad DESCARGA DE HUMOS CAMPANA DE EVACUACIÓN EXTERNA EXTRACTORA En esta versión los humos y vapores son canalizados hacia el ambiente exterior a través del tubo de descar ga Para ello el racor de salida de la campana debe conec tarse mediante un tubo a una salida externa El tubo de salida debe tener un diámetro no inferior al del racor de la campana una ligera inclinación hacia a...

Page 28: ...rcha o se configura el motor a la velocidad media 3 Botón 3 Al pulsar la tecla tecla apretada se pone en marcha o se configura el motor a la velocidad máxima PANEL DE MANDOS ELECTRÓNICO Motor ON OFF Aumento de la velocidad de 1 a MAX Velocidad máxima con SRS desactivado Velocidad 4 solo está acti va durante pocos minutos a continuación vuelve a la velocidad 3 Velocidad máxima con SRS activado Velo...

Page 29: ...umo y una vida útil prolongada en condiciones de uso normales Si es necesario sustituir la bombilla siga los pasos ilustrados en la figura 12V 3 1 2 ELIMINACIÓN AL FINAL DE LA VIDA ÚTIL El símbolo del contenedor tachado que se encuentra en su equipo indica que el producto es un RAEE es decir un Resi duo de Aparatos Eléctricos y Electrónicos y por tanto no se puede eliminar en la basura indiferenci...

Page 30: ...rra non risultino chiare o in caso di dubbi sulla corretta messa a terra dell ap parecchio Non usare prolunghe Se il cavo di alimentazio ne è troppo corto contattare un elettricista qua lificato per far installare una presa in prossimità dell apparecchio ISTRUZIONE DI SICUREZZA E AVVERTENZE LEGGERE E CONSERVARE LE PRESENTI ISTRUZIONI Il lavoro d installazione deve essere esegui to da installatori ...

Page 31: ... di pulizia sullo stesso Il Costruttore declina ogni responsabilità per eventuali danni che possano direttamente o in direttamente essere causati a persone cose ed animali domestici conseguenti alla mancata os servanza delle avvertenze di sicurezza indicate in questo libretto È molto importante che questo libretto istruzioni sia conservato insieme all ap parecchiatura per qualsiasi futura consulta...

Page 32: ...e superare 3 lb 5 oz 1 5 Kg Controllare le friggitrici durante l uso I olio surriscal dato potrebbe infiammarsi Non accendere fiamme libere sotto la cappa Non preparare cibi alla fiamma sotto la cappa Non utilizzare mai la cappa senza i filtri metallici anti grasso grasso e sporco in questo caso si depositereb bero nell apparecchio compromettendone il funzio namento Parti accessibili della cappa p...

Page 33: ...A tal fine il raccordo d uscita della cappa deve essere collegato tramite un tubo ad un uscita esterna Il tubo d uscita deve avere un diametro non inferiore a quello di raccordo della cappa una leggera inclinazione verso il basso caduta nei tratti orizzontali per evitare che la condensa refluisca nel motore il numero minimo indispensabile di curve la lunghezza minima indispensabile per evitare vib...

Page 34: ...re alla velocità media 3 Pulsante 3 Premendo il tasto tasto rientrato si avvia o si imposta il motore alla velocità massima PULSANTIERA ELETTRONICA Motore ON OFF Incremento velocità da 1 a MAX Velocità massima con SRS disabilitato Velocità 4 è attiva solo per pochi minuti poi si ritorna a velocità 3 Velocità massima con SRS abilitato Velocità 3 o velocità 2 Le velocità sono segnalate dai led pre s...

Page 35: ...ifferenziata cioè insieme ai rifiuti urbani misti ma deve essere gestito separata mente così da essere sottoposto ad apposite operazioni per il suo riuti lizzo oppure a uno specifico trattamento per rimuovere e smaltire in modo sicuro le eventuali sostanze dannose per l ambiente ed estrarre le materie prime che possono essere riciclate Lo smaltimento corretto di questo prodotto contribuirà a salva...

Page 36: ...Code 110033041 Ed 01 2022 Codice Code Matricola Serial Number Falmec S p A via dell Artigianato 42 z i 31029 Vittorio Veneto Treviso Italy info falmec com falmec com ...

Reviews: