 SAFETY INSTRUCTIONS
 AND WARNINGS

READ AND SAVE THESE INSTRUCTIONS

Installation operations are to be carried 
out by skilled and qualified installers in ac-

cordance with the instructions in this booklet and 
in compliance with the regulations in force.
DO NOT use the hood if the power supply cable 
or other components are damaged: 

disconnect 

the hood from the electrical power supply and con-
tact the Dealer or an authorised Servicing Dealer for 
repairs. 

Do not modify the electrical, mechanical or 
functional structure of the equipment.
Do not personally try to carry out repairs or 
replacements. Interventions carried out by 
incompetent and unauthorised persons can 
cause serious damage to the unit or physical and 
personal harm, not covered by the Manufacturer's 
warranty.

WARNING: TO REDUCE THE RISK OF FIRE, ELEC-
TRIC SHOCK, OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by 
the manufacturer. If you have questions, contact 
the manufacturer.
b) Before servicing or cleaning unit, switch pow-
er off at service panel and lock the service dis-
connecting means to prevent power from being 
switched on accidentally.
When the service disconnecting means cannot 
be locked, securely fasten a prominent warning 
device, such as a tag, to the service panel.

CAUTION: For General Ventilating Use Only. Do 
Not Use To Exhaust Hazardous Or Explosive Ma-
terials And Vapors.

WARNINGS FOR THE INSTALLER

TECHNICAL SAFETY

Before installing the hood, check the integ-
rity and function of each part. Should 

anomalies be noted, do not proceed with installa-
tion and contact the Dealer.

Do NOT install the hood if an aesthetic (or cos-
metic) defect has been detected. Put it back into 
its original package and contact the dealer.
No claim can be made for aesthetic (or cosmetic) 
defects once it has been installed.

During installation, always use personal protective 
equipment (e.g.: Safety shoes) and adopt prudent 
and proper conduct.
The installation kit (screws and plugs) supplied with 
the hood is only to be used on masonry walls: in case 
of installation on walls of a different material, assess 
other installation options keeping in mind the type of 
wall surface and the weight of the hood (indicated on 
spec sheets at the beginning of this manual).
Keep in mind that installations with different types of 
fastening systems from those supplied, or which are 
not compliant, can cause electrical and mechanical 
seal danger.
Do not install the hood outdoors and do not expose 
it to atmospheric elements (rain, wind, etc.).

All set screws must be checked, and retightened 
where necessary, before installation.

CAUTION: To Reduce The Risk Of Fire And Electric 
Shock, Install This Rangehood Only With Remote 
Blower Or Integral Blowers Manufactured by FAL-
MEC S.p.A. Models “Remote in-roof Blower”.

ELECTRICAL SAFETY

The installation has to be in accordance with the 
National Electrical Code, ANSI/NFPA 70 and local 
codes. Making sure the power is off before at-
tempting installation.

The electrical system to which the hood is 

to be connected must be in accordance 

with local standards and supplied with earthed 
connection in compliance with safety regulations 
in the country of use. It must also comply with lo-
cal standards regarding radio antistatic proper-
ties. 

WARNING: GROUNDING INSTRUCTIONS
This appliance must be grounded. In the event of 
an electrical short circuit, grounding reduces the 
risk of electric shock by providing an escape wire 
for the electric current. This appliance is equipped 
with a cord having a grounding wire with a 
grounding plug. The plug must be plugged into 
an outlet that is properly installed and grounded.

WARNING: Improper grounding can result in a risk 
of electric shock. Consult a qualified electrician if 
the grounding instructions are not completely 
understood, or if doubt exists as to whether the 
appliance is properly grounded.
Do not use an extension cord. If the power supply 
cord is too short, have a qualified electrician in-
stall an outlet near the appliance.

Summary of Contents for Elle

Page 1: ...INSTRUCTIONS BOOKLET Elle Design INSTRUCTIONS BOOKLET EN MODE D EMPLOI FR MANUAL DE INSTRUCCIONES ES LIBRETTO ISTRUZIONI IT...

Page 2: ...22 1 2 574 12 9 16 321 mm 49 1243 max 27 1 2 700 min 10 3 16 259 mm 20 1 16 510 mm 68 1750 mm 20 1 16 510 mm 23 5 8 600 mm 11 3 8 290 mm 7 16 11 mm 16 1 2 420 mm 17 6 8 450 mm 50 6 8 1289 mm 23 5 8 6...

Page 3: ...6 16 316 mm 11 3 16 285 mm 7 7 8 200 mm 10 254 mm 1 6 mm EN Side outlet which can only be used with false ceiling FR Sortie lat rale utilisable unique ment avec faux plafond ES Salida lateral utilizab...

Page 4: ...s nationaux et locaux qui remplacent toutes les recommandations stipul es dans le pr sent document ES Medidas instalaci n La altura de montaje recomendada desde la super cie de cocci n hasta el fondo...

Page 5: ...ielo raso 4 IT installazione su soffitto con senza controsoffitto 4 4 3 V2 x8 T T1 1 H1 EN Preliminary operations separate upper trellis from lower trellis 3 FR Op rations pr liminaires s parer le rai...

Page 6: ...ie rod supports 5 FR Fixation des supports pour tirants 5 ES Fijaci n de los soportes para tirantes 5 IT Fissaggio supporti per tiranti 5 7 7 8 200mm 10 255mm 7 16 11mm 10 255mm 45 1 8 1146mm 11 3 16...

Page 7: ...8 FR Installation du clapet anti retour 6 Montage du tuyau d as piration 7 Assemblage de la chemin e et de l extension 8 ES Instalaci n de la v lvula antirretorno 6 Montaje del tubo de aspiraci n 7 Mo...

Page 8: ...de chimenea en techo 9 IT Montaggio camino a soffitto 9 1 C E I L I N G 2 V3 x4 FALSE CEILING V4 x8 SP 1 2 3 V3 x4 EN Mount chimney on false ceiling 10 FR Montage de la chemin e au faux plafond 10 ES...

Page 9: ...EN Metallic filters 11 and remove panel 12 FR Les filtres m talliques 11 et retirer le panneau 12 ES Los filtros met licos 11 y quitar el panel 12 IT Filtri metallici 11 e togliere pannello 12 2 1 3...

Page 10: ...1 2 3 4 5 YES YES NO NO B A 2 1 14 13 EN Mount motor chamber 13 and tie rods 14 FR Montage de la chambre du moteur 13 et des tirants 14 ES Montaje de la c mara del motor 13 y tirantes 14 IT Montaggio...

Page 11: ...accord lectrique 15 et fixation de la chemin e 16 ES Conexi n el ctrica 15 y fijaci n de la chimenea 16 IT Collegamento elettrico 15 e fissaggio camino 16 16 EN Mandatory safety screws FR Vis de s cur...

Page 12: ...EN Installing the carbon zeolite filter optional FR Installation du iltre charbon zeolite en option ES Instalacion de iltro de carbon zeolita opcional IT Installazione filtro carbone zeolite opzional...

Page 13: ...13 V3 x12 3 1 2 20 EN LED maintenance 19 20 FR Entretien des LED 19 20 ES Mantenimiento de las luces LED 19 20 IT Manutenzione luci LED 19 20 19 1 2...

Page 14: ...y shoes and adopt prudent and proper conduct The installation kit screws and plugs supplied with the hood is only to be used on masonry walls in case of installation on walls of a di erent material as...

Page 15: ...o comply with the safety warnings indicated in this booklet It is imperative that this instructions booklet is kept together with the equipment for any future consultation If the equipment is sold or...

Page 16: ...ling the hood carefully read the section SAFETY INSTRUCTIONS AND WARNINGS TECHNICAL FEATURES The technical speci cations are exhibited on the labels located inside the hood POSITIONING The minimum dis...

Page 17: ...educe speed from 4 to 1 Light on off TIMER red LED ashing Auto switch o after 15 min The function deactivates red LED o if The TIMER key is pressed again The ON OFF key is pressed FILTER ALARM red LED...

Page 18: ...permitted however it may cause the lter material to darken to reduce the possibility of this problem from happening use low tem perature washes 131 F 55 C max To extract and insert the metal anti gre...

Page 19: ...e Reven deur Apr s son installation aucune r clamation ne sera accept e pour des d fauts esth tiques Pendant l installation toujours utiliser des quipe ments de protection individuelle ex des chaussur...

Page 20: ...es de cuisson peuvent nuire au bon fonctionnement des appareils qui br lent du gaz ou d autres combustibles y compris ceux qui se trouvent dans d autres pi ces en raison du re ux des gaz de combustion...

Page 21: ...u en agissant sur l interrupteur g n ral Ne pas utiliser la hotte avec les mains mouill es ou les pieds nus Contr ler toujours que toutes les parties lectriques lumi res aspirateur soient teintes lors...

Page 22: ...de non retour est ins tall en pr sence des moteurs avec 800 m3 h ou sup rieurs D viation pour l Allemagne quand la hotte de la cuisine et des appareils aliment s avec une nergie di rente de l nergie...

Page 23: ...nt 2 ENTRETIEN Avant de proc der toute op ration de nettoyage ou d entre tien d sactiver l appareil en enlevant la fiche ou en agissant sur l interrupteur g n ral Il ne faut pas utiliser de d tergents...

Page 24: ...ces d chets conform ment la l gislation nationale INFORMATIONS SUR L LIMINATION DANS LES PAYS DE L UNION EU ROP ENNE La directive communautaire sur les appareils DEEE a t transpos e en mode di rent p...

Page 25: ...n utilice siempre equipos de protecci n personal ej calzado de protecci n contra accidentes y adopte comportamientos prudentes y correctos El kit de jaci n tornillos tacos y abrazaderas que se entreg...

Page 26: ...ro de los aparatos que queman gas u otros combustibles incluidos los que se en cuentran en otras habitaciones debido al re ujo de los gases de combusti n Dichos gases pueden po tencialmente derivar en...

Page 27: ...bres debajo de la campana No use nunca la campana sin los ltros met licos an tigrasa en este caso la grasa y la suciedad se deposi tar an en el equipo perjudicando su funcionamiento Las partes accesib...

Page 28: ...ciones de montaje En esta versi n la v lvula de no retorno no debe estar montada des m ntela si est presente en el racor de salida del aire del motor INSTRUCCIONES DE MONTAJE parte reservada al person...

Page 29: ...ntengan sustancias abrasivas ci das o corrosivas ni pa os con superficies rugosas Un mantenimiento constante asegura un buen funcionamiento y un ptimo rendimiento a lo largo del tiempo Preste especial...

Page 30: ...AL FINAL DE LA VIDA TIL El s mbolo del contenedor tachado que se encuentra en su equipo indica que el producto es un RAEE es decir un Residuo de Aparatos El ctricos y Electr nicos y por tanto no se pu...

Page 31: ...sione di rete corrisponda a quella riportata dalla targhetta posta all interno della cappa La presa usata per il collegamento elettrico deve es sere facilmente raggiungibile con l apparecchiatura inst...

Page 32: ...bini non devono giocare con l apparecchio La pulizia e la manutenzione a cura dell utilizzatore non deve essere e ettuata da bambini senza sorveglianza AVVERTENZE PER L UTILIZZO E LA PULIZIA AVVERTENZ...

Page 33: ...gue giallo verde per la messa a terra blu per il neutro e il lo marrone per la fase La spina deve essere collegata ad un adeguata presa di sicurezza apparecchio sso non provvisto di cavo di alimentazi...

Page 34: ...adiocomandi nella stessa stanza possibile generare un nuo vo codice con la seguente procedura Togliere alimentazione alla cappa prima di effettuare la procedura 1 GENERARE UN NUOVO CODICE La procedura...

Page 35: ...ntribuir a salvare preziose risorse ed evitare potenziali e etti negativi per la salute umana e per l ambiente che potrebbero essere cau sati da uno smaltimento inappropriato dei ri uti Vi preghiamo d...

Page 36: ...Codice Code Matricola Serial Number Falmec S p A via dell Artigianato 42 z i 31029 Vittorio Veneto Treviso Italy info falmec com falmec com Code 110033127 Ed 00 2023...

Reviews: