6
TECHNICAL SPECIFICATIONS
B
The technical data pertaining to the electric appliance The technical specifica-
tions of the appliance are shown on the rating plates located inside the range
hood.
INSTALLATION
C
(Section reserved for qualified installers of the range hood)
The distance between the hob and the lowest part of the rangehood is nor-
mally at least 65 cm (see figure C1). This distance is measuresd in the lowest
part of the rangehood not operating at safety voltage. Based on this detail
provided by European Standards, the distance may be reduced in some mod-
els as specified in the general catalogue. If the instructions for installation for
the gas hob specify a greater distance, this has to be taken into account.
In the outside exhaust version, the diameter of the entire duct run must be no
smaller than the range hood connection.
In the horizontal duct run, the duct must slope slightly (around 10%) upwards,
so as to better ventilate the air outside of the room.
Avoid using angled pipes, make sure that the pipes are at least of the mini-
mum length.
Comply with the current regulations on air discharge into the atmosphere.
If a boiler, stove, fireplace, etc. that uses gas or other fuels is being used at
the same time, make sure the room where the fumes are extracted is well
ventilated, in compliance with the current regulations.
Mounting instruction: see section “O” of the booklet.
ELECTRICAL CONNECTIONS
D
(Section reserved for qualified installers)
WARNING!
Before doing any work inside the range hood, disconnect the appliance from
the mains power supply.
Check that the wires inside the range hood are not disconnected or cut; if this
is the case, contact your nearest service centre. The electrical connections must
be performed by qualified personnel.
The connections must be performed in compliance with the legal standards in
force. Check that the receptacle and wiring are able to support the load of the
appliance (see the technical specifications in point B).
THIS APPLIANCE MUST BE GROUNDED.
Important:
The hood comes equipped with a 5 ft(1.5 m) power cord with a NEMA 5-15
molded plug for connection to a 120 VAC, 60 Hz, 15 A power outlet. This outlet
must be located in the duct cover area above the hood.
Some types of appliance are supplied with a cable without plug; in this case,
“standardised” or a junction box must be used, keeping in mind that:
- the yellow-green wire must be used for the earth,
Summary of Contents for DANILO-PROLITE INSERT 38" 2M
Page 5: ...3 HOOD INSERT STEP 1 STEP 2 STEP 3 A A A A B B B B B Fig C Fig O ...
Page 30: ...Note ...
Page 31: ......
Page 32: ......