38
Australia
Technical Data
This cooker is designed for use on Natural Gas:-
A conversion for LP (LPG X Propane (2.75kPa)) gas is available.
INSTALLER: Please leave these instructions with the User.
DATA BADGE LOCATION:
Cooker back, serial number repeater badge below oven door opening.
Country of Destination: Australia
Gas
Electric
Natural gas
0.95kPa (1kPa nominal)
220 - 240V 50Hz
Propane
2.75kPa
(See appliance data badge for test pressures)
Dimensions
Overall height minimum
893mm maximum 920mm
Overall width
900mm See ‘Positioning of Cooker’
Overall depth
648mm
Space for fixing
See ‘Positioning of Cooker’
Minimum space above hotplate
650mm
Connections
Gas:
Electric
Rp
1
/
2
at rear right-hand side
220 - 240V 50Hz
Standard burner Wok burner
A injector,
B internal injector,
C external injector
Ratings
Natural gas 1.0kPa
LPG X 2.75kPa
Injector
Injector
Hotplate
Wok burner
15.2MJh
-1
internal 112 15.2MJh
-1
internal 66
external 164
external 91
Large Burner
12.3MJh
-1
165
12.0MJh
-1
89
Medium Burners 6.2MJh
-1
115
6.2MJh
-1
67
Small Burner
3.7MJh
-1
92
3.3MJh
-1
48
Gas burner inputs based on Gross Calorific Value
Main Oven
2.5kW
2.5kW
Tall Oven
2.5kW
2.5kW
Grill
2.3kW
Maximum total electrical load at 230V 7.4kW*
*approximate total including oven lights, oven fan etc.