SUP Series™ UPS
700VA & 1kVA
Model Number
SUP700-1C
SUP1.0K-1C
Nominal VA
700
1000
Electrical Input
Nominal AC Voltage
120V or 230V
120V or 230V
Current-Amps
7 (120V), 3.6 (230V)
10 (120V), 5.2 ( 230V)
AC Voltage Window
-21% to 25%
Frequency
50/60 Hz (Auto – Tracking)
Frequency Range
47 – 63Hz
UPS is designed for use on 120V domestic or 230V international utility power with neutral, line and ground connections.
Electrical Output
Watts
490
650
Nominal AC Voltage
120V
120V
Frequency
50/60 Hz (Auto-Tracking)
On-Line Voltage Regulation
± 8%
On Battery Voltage Regulation
± 8% Typical (prior to low battery warning)
Waveform
True Sinewave
Surge Protection
125 Joules MOV
Unit Protection
Short Circuit, Overload & Over Temperature
Efficiency AC to AC (Typical)
97% (120Vac Input), 90% (230Vac Input)
Battery
DC Voltage
24V
24V
Type
12V, 7AH x 2
Lead Acid Maintenance-Free
12V, 9AH x 2
Lead Acid Maintenance-Free
Back Up Time @ Full Load
@ 1/2 Load
5 Minutes
12 Minutes
4.5 Minutes
11 Minutes
Recharge Time
5 Hours to 90%
Battery times are approximate.
Transfer Time
Bypass to Inverter
Black-out, 3ms / Brown-out, 0ms
Inverter to Bypass
0ms
Electrical Connections
Input
1 - 6’ Cord with 5-15P &
1 – 6’ Cord with Schuko
1 - 6’ Cord with 5 -15P &
1 – 6’ Cord with Schuko
Output
(3) 5-15R
(3) 5-15R
Environmental
Operating Temperature
0º C - 40º C (32º F to 104º F)
Altitude
7,000 Feet
Humidity
10% to 95% Non – Condensing
Cooling
Low Velocity Forced Air Fans
Audible Noise @ 1 meter
< 45dBA
Controls and Indicators
Control
One Main Control Button – UPS On/Off, Self Test, Reset & Silence Alarms
Selection Control
Two LCD Metering Scroll Function Select Buttons
LCD Display
AC Input Voltage, AC Output Voltage, Output Frequenc y, DC Battery Voltage, Internal UPS
Temperature,
Timer – Minutes to Shutdown, Hours to Restart, Battery – Remaining Battery Time
LCD Operational Symbols
Overload, Load Level, UPS is Loaded, Normal Mode, Buck Mode, Boost Mode, Timer Enabled,
High Temperat ure, Fan Off, Alarm Off, UPS Fault, Battery Low, Battery Level
Audible Alarms
Low Battery, Defective Battery, Low Battery, Overload, Over Temperature, AC Out of Range
Communications
RS-232 Serial Port and Contact Closure Signal interface (Bundled UPSil on 2000 Software)
Mechanical
Dimensions H x W x D
Inches (mm)
7.9 x 7.1 x 14.2 (200 x 180 x 360)
Weight lb. (kg)
33.1 (15)
33.1 (15)
Agency Listing
UL1778, CUL, FCC Class A
Note: The UPS will go to Green Mode whenever the output load is under 30 watts.
Falcon Electric, Inc. - 5106 Azusa Canyon Rd. - Irwindale, CA 91706 - 800.842.6940 Fax 626.962.7720
www.falconups.com - email:[email protected]
©2004 Falcon
®
Electric, Inc. All rights reserved. Falcon
®
and the Falcon Electric logo are registered trademarks of Falcon Electric, Inc.
All other brand names and trademarks are the property of their respective owners.
The information and specifications stated in this document are subject to change without notice. 01-07-04 MD44034-A
17