WARNING – SERVICING TO BE CARRIED OUT ONLY BY AN AUTHORISED PERSON
Disconnect from electricity and gas before servicing. Check appliance is safe when you have finished.
28
Conversion from Natural Gas (1.0 kPa)
to LPG X Propane (2.54 kPa)
n
n
A suitably competent person must perform the
conversion. After conversion the installation must
comply with the relevant regulations and also the
local electricity supply company requirements. Read
the instructions before converting this appliance.
n
n
Failure to convert the appliance correctly could
invalidate any warranty or liability claims and lead
to prosecution.
n
n
The conversion instructions must be used in
conjunction with the rest of the appliance
instruction, in particular for information on
Standards, cooker positioning, connection, hose
suitability, etc.
n
n
When servicing or replacing gas-carrying
components, disconnect from the gas before
starting, and check that the appliance is gas sound
after completion.
n
n
DO NOT use reconditioned or unauthorised gas
controls.
n
n
Disconnect from the electricity supply before
conversion. Before electrical reconnection, check
that the appliance is electrically safe.
Injectors
Remove the burner caps and heads. Remove the old jets.
Fit the new jets: see
‘Technical Data’
section for correct jets.
Reassemble in the reverse order
(Fig.8-1)
.
Tap Adjustment
Removing the Control Panel
DISCONNECT FROM THE ELECTRICITY SUPPLY.
Remove all control knobs. Open the oven door. Undo the
4 screws on the oven beak
(Fig.8-2)
. Remove the 3 fixing
screws on the underside of the control. The control panel
should drop down slightly. It is held at each end by two holes
in the top edge
(Fig.8-3)
that locate on the tags on the inner
panel.
Lift the control panel clear of the tags and pull the control
panel forward.
Take care not to damage or strain the wiring.
Bypass Screw Adjustment
Turn the bypass screw on each control clockwise to the stop
(Fig.8-4)
.
Refit the control panel.
A
B
C
ArtNo.311-0010 Injectors
A – Jet, B – Internal injector, C – External injector
ArtNo.061-0006 - 90SC - Removing the splitter
ArtNo.270-0032 - 90 Prof+ FX - Removing the control panel
ArtNo.0102-0011 - Screwing
the control valve bypass screw
8. Conversion to Propane Gas
Fig. 8.1
Fig. 8.2
Fig. 8.3
Fig. 8.4