background image

Ver. 3/13

Attachment of Steam Hose

Insert the hose connector into the steamers vacuum-steam port as shown (fig. 8) by pressing the

plug into the port until button clicks. Check that the connector is firmly positioned by gently pulling

backward on it to ensure it is locked in place. Ensure that the hose is firmly connected to the

machine! To disconnect the hose from the steamer, press the connector button “A” (fig. 8) and pull

to separate it from the steamer

Machine Steam Function

Turn the main power switch on (fig. 9) to activate the display. Press button to turn on the boiler (fig.

10). The steam icon (fig.10) on the display will blink. When the steam icon stops blinking (about 10-

12 minutes) the steamer is ready to generate steam.

PLEASE NOTE:

Do not begin dispensing steam if the steam icon is blinking when first turned on. Wait

until the icon has switched to non-blinking mode and the system is ready to use.

Press the steam demand button (fig. 11) on the handle to start dispensing. Press the steam volume

adjustment button located on the top of the handle (fig.12) to vary the flow of steam. There are

three steam-flow settings as indicated by the LCD display (fig.10)

Some drops of liquid water may form when the steamer is first used. This is from condensation

within the sleeve. Aim the first steam jet toward a piece of cloth to catch the liquid until the jet

becomes uniformly steam.

Steam/detergent function

Press detergent button on the control panel (fig. 10). The detergent icon on the display will start to

blink. The machine is now ready to dispense detergent on demand.

To dispense detergent, press the detergent on/off button on the operators handle (fig.12). This

enables the pump to deliver the detergent solution when the on demand steam button is activated

(fig. 11).

The unit will continue to dispense detergent until it is turned off. To turn-off the detergent function,

press the on/off button

once

. The icon will flash to indicate this function is now disabled. To turn off

the detergent function completely, press the red button on the control panel

once

(fig.10).

No water

When there is no water in the water reservoir the no water icon on the display (fig. 10) begins to

blink, along with an audible alarm. To refill the tanks, follow the “filling water and detergent tanks”

instructions above.

13

Summary of Contents for Peregrine 1800 S

Page 1: ...Ver 3 13 Operators Use and Care Manual...

Page 2: ...nctions Page 4 Included accessories and tools Page 5 Safety Instructions Page 6 Assembly Instructions Page 7 Quick Start Guide Page 8 Specifications Page 10 General Maintenance Instructions Page 11 Op...

Page 3: ...and knobs and locking levers for operators handle 2 Control Panel see next page for panel functions 3 Steam Vacuum port 4 Detergent dilution adjustment knob 5 Tool Caddy 6 Water Detergent reservoir an...

Page 4: ...n red right 3 Maintenance Required Icon 4 Water Reservoir Empty Icon audible alarm sounds 5 Tank Pressure Indicator 6 Tank Temperature Indicator 7 Boiler Heating Element Icon blinks when heating 8 Ste...

Page 5: ...Detail Cleaning Wand 3 5 6 Detail Cleaning Wand 10 5 7 Triangular fitted brush 8 Round fitted brush 9 Stainless Steel brush for detail wand small 10 Brass brush for detail wand small 11 Nylon brush fo...

Page 6: ...surface use gloves 3 Protect against fire electric shock and personal injury do not place cord plugs or steamer in standing water or other liquid 4 Keep the unit and accessories out of the reach of ch...

Page 7: ...is for use on a nominal 120 volt circuit and has a grounding attachment plug that looks like the plug illustrated the figure to the right Make sure that the appliance is connected to an outlet having...

Page 8: ...to clean it is your responsibility to ensure the manufacturer of the chemical warrants it for use in dry vapor steam generators DO NOT use chemicals that are not approved for use in a steam generator...

Page 9: ...eaning process push the detergent button on the control panel fig 10 and the detergent injection button on the operator handle fig 12 Adjustment to the amount of chemical being dispensed can be done b...

Page 10: ...age 120V 60Hz Maximum power 1800W Maximum boiler heating element power 1000 700W AISI 304 stainless steel boiler Steam pressure 87PSI Steam temperature 316 F Capacity of water tank 5 gal Max Capacity...

Page 11: ...end of every operation day check the boiler maintenance icon on the control panel fig 5 If the unit needs service the indicator will say Clean If the indicator is on reference the parts and operations...

Page 12: ...FILLED WITH WATER NEVER ADD DETGERGENT IN THE WATER RESERVOIR Use of a detergent in the water tank may seriously damage the product If a funnel is used to fill the detergent tank rinse the funnel unde...

Page 13: ...andle fig 12 to vary the flow of steam There are three steam flow settings as indicated by the LCD display fig 10 Some drops of liquid water may form when the steamer is first used This is from conden...

Page 14: ...r of the machine Regular and planned maintenance must be performed and are not covered under warranty The warranty does not provide coverage for breakdowns problems or accidents caused by misuse impro...

Page 15: ...nd signal The water level in the tank is low The probe cap is loose Fill the tank with water and start up the steamer once more Remove the cap flap and check that the probe cap is correctly screwed on...

Page 16: ...Ver 3 13 Falcon ProSolutions Inc 16026 University Oak San Antonio Texas 78249 210 547 2741 16...

Reviews: