47
WARNING - SERVICING TO BE CARRIED OUT ONLY BY AN AUTHORISED PERSON
Disconnect from electricity and gas before servicing. Check appliance is safe when you have finished.
Conversion to LP gas
Check in the Technical Data section at the back of the
book that the cooker is convertible to the gas you want
to use.
This conversion must be performed by a competent person.
After conversion the installation must comply with the
relevant regulations and also the local electricity supply
company requirements. Read the instructions before
converting this appliance.
Failure to convert the appliance correctly could invalidate
any warranty or liability claims and lead to prosecution.
This instruction must be used in conjunction with the rest
of the appliance instruction, in particular for information on
Standards, cooker positioning, connection hose suitability
etc.
When servicing or replacing gas-carrying components
disconnect from gas before commencing operation and
check appliance is gas sound after completion.
Do not use re-conditioned or unauthorised gas controls.
Disconnect from the electricity supply before commencing
servicing. Before electrical re-connection, check that the
appliance is electrically safe.
Injectors
Remove burner caps and heads. Remove old jets. Fit the
new jets. See the Technical Data section at back of the
book for the correct jets. Reassemble in reverse order.
Tap adjustment
Disconnect from electricity supply.
Pull off all the control knobs.
Open the grill and right hand oven doors and remove the 4
fixing screws underneath the control panel.
The control panel should drop down slightly. It is held at the
top by two holes in the top edge one at each end that locate
on tags on the inner panel.
Clear the holes from the inner panel and pull the control
panel forward.
Take care not to damage or strain the wiring.
To convert to LP gas.
Unscrew the tap bypass screw.
Using a pair of long nose pliers carefully remove the bypass
screw and fit the correct replacement screw. See the
Technical Data section at back of the book for the correct
size. Tighten the screw down.
Refit the control panel. Locate the holes in the top edge on
the tags on the inner panel and replace the fixing screws in
the bottom edge.
Stick on label
Stick the LP gas label over the natural gas part of the
appliance data label.
Pressure Testing
Connect the appliance to the gas supply. Check the
appliance is gas sound.
The gas pressure can be measured at one of the left hand
hotplate burner jets. Lift off a burner head. Fit the pressure
gauge to the jet. Turn on the hotplate burner and turn on
and light one of the other burners.
The pressure should be 29mbar for Butane and 37mbar for
Propane. After checking the pressure, turn the taps off and
replace the burner head.
Reassemble burner top, making sure it is reassembled in the
correct way on the burner body.
Check the appliance is gas sound.
Check operation of all the burners.