31
09
N/A
N/A
N/A
10
Communication
Error
Reset Appliance
Switch Appliance OFF for
10 Seconds then On.
Failure on LIN or CAN-Bus
Check all
communications
connections
11
Initialisation Error
Reset Appliance
Switch Appliance OFF for
10 Seconds then On.
Software Failure while
initialising hardware
Wait. The generator will
reset every 30 seconds.
Replace Generator .
12
Current Reading
Failure
Reset Appliance
Switch Appliance OFF for
10 Seconds then On.
Generator suspects
Current being generated
does not reflect what
appliance controls are set
for.
Check Mains Supply
Check all electrical
connections within
appliance.
Replace Suspect Coil
Replace Generator .
13
Mains Connection
Error
Reset Appliance
Switch Appliance OFF for
10 Seconds then On.
Mains voltage too high or
too low
See Fault 8
14
Mains Connection
Error
Reset Appliance
Switch Appliance OFF for
10 Seconds then On.
Mains voltage too high or
too low
See Fault 8
15
Coil Electrical
Circuit Self-
Protected.
Reset Appliance
Switch Appliance OFF for
10 Seconds then On.
See Fault 4
See Fault 4
O1
Oven will not
operate
No power to unit
Check oven zone
(element selector) switch
is on, turn temperature up
Summary of Contents for i9042
Page 10: ...10 2 3 3 Ensure you use the correct type of pot 2 3 4 Ensure you use a clean flat bottom pan ...
Page 22: ...22 7 3 3 Remove cross supports 7 3 4 Pull generator and electrics out as shown ...
Page 24: ...24 7 3 7 Loosen top screws and remove lower screws both sides to remove generator ...
Page 33: ...33 9 0 CIRCUIT DIAGRAM i91104 5 Circuit Diagram ...
Page 34: ...34 10 0 WIRING DIAGRAM i91104 5 Wiring diagram ...
Page 35: ...35 i91104 5 Wiring diagram ...