30
04
Cooking Zone
Temperature Too
High Or Remains
Constant During
Cooking.
Reset Appliance
Switch Appliance OFF for
10 Seconds then On.
Pan empty / Too Hot
Test Disc may be
overheated – allow for
cooling.
Cooking Zone Self
Protected due to Abnormal
Heat Build up
Allow Cook Zone to cool
for couple of Minutes
Temperature sensor faulty
(Constantly records a
Ambient Temperature)
Check all electrical
connections to the
inductor coil
Replace defective Coil
05
Controls Failure
Reset Appliance
Switch Appliance OFF for
10 Seconds then On.
Controls faulty or
incorrectly Wired
Check all electrical
connections to the
controls & Generator
Replace defective
Controls Assembly
06
Generators
Internal
Temperature Too
High.
Reset Appliance
Switch Appliance OFF for
10 Seconds then On.
See Fault 3
See Fault 3
07
Cooking Zone
Temperature
Sensor
Reset Appliance
Switch Appliance OFF for
10 Seconds then On.
Temperature sensor faulty /
Malfunctioned
Check all electrical
connections to the
inductor coil
Replace defective Coil
08
Mains Supply
Failure
Reset Appliance
Switch Appliance OFF for
10 Seconds then On.
Fault in mains supply
Is there a Phase(s) Down
Has supply been
interrupted intermittently?
Has MCB Tripped
Has Supply Under / Over
Voltage?
Summary of Contents for i9042
Page 10: ...10 2 3 3 Ensure you use the correct type of pot 2 3 4 Ensure you use a clean flat bottom pan ...
Page 22: ...22 7 3 3 Remove cross supports 7 3 4 Pull generator and electrics out as shown ...
Page 24: ...24 7 3 7 Loosen top screws and remove lower screws both sides to remove generator ...
Page 33: ...33 9 0 CIRCUIT DIAGRAM i91104 5 Circuit Diagram ...
Page 34: ...34 10 0 WIRING DIAGRAM i91104 5 Wiring diagram ...
Page 35: ...35 i91104 5 Wiring diagram ...