3.2 BURNERS

Burners should be cleaned periodically to maintain

maximum performance and are best cleaned with a wire

brush. Blocked parts require to be cleared using a metal

broach. Any material pushed into burner should be

shaken out via air inlet.

3.2.1 Removal of Burner Assembly

Turn off main gas supply to unit. Remove fixings that

secure pilot and cross-lighter assemblies to main burner

and drop assemblies slightly. Disconnect compression

joint above manifold. Remove fixings that retain burner

assembly front cross strap to side runners. Pull burner

assembly forward 

(approx. 25mm)

and drop it slightly to

clear front cross strap. While supporting weight of

assembly, push it back to clear rear strap from runners

and lower to withdraw. Replace in reverse order.

3.2.2 Removal of Pilot Burner

Isolate main gas supply to unit. Disconnect pilot supply

pipe compression nut and remove pipe from pilot burner.

Withdraw injector. Undo thermocouple retaining nut and

remove thermocouple from pilot burner. Undo thermopile

retaining nut and withdraw thermopile. Pull lead from

spark electrode.

Undo nuts that secure pilot burner bracket to burner.

Withdraw pilot burner assembly. Replace in reverse

order.

3.3 CLEANING THE INJECTORS

Injectors should be periodically cleaned using a wooden

splinter or soft wire. Avoid use of metal reamers as these

may distort or increase size of orifice.

3.3.1 Removal of Main Burner Injectors

Isolate main gas supply.

Use a 10mm open-ended spanner to remove injector.

3.3.2 Removal of Pilot/Cross-Lighting Injectors

Isolate main gas supply. Undo pilot/cross lighter supply

pipe compression nut and remove pipe from pilot/cross

lighter burner. 

Withdraw injector. Replace in reverse order.

3.4 FLAME FAILURE THERMOCOUPLE

Undo nuts at pilot assembly and valve body.

Disconnect thermocouple interrupter from terminal block.

2.7 INSTRUCTION TO USER

After installing and commissioning the fryer, hand User

Instructions to operator or purchaser. Ensure details to

light, turn off, use and clean are properly understood.

The main gas isolating valve location should be made

known to user and the procedure for operation in event of

an emergency should be demonstrated.

SECTION 3 - 
SERVICING and CONVERSION

Important

BEFORE ATTEMPTING ANY SERVICING, ENSURE

ISOLATING COCK IS TURNED OFF AND THAT IT

CANNOT BE INADVERTENTLY TURNED BACK ON.

FRYER REQUIRES TO BE COOLED AND DRAINED

PRIOR TO MAINTENANCE.

AFTER ANY SUCH MAINTENANCE TASK, CHECK THE

APPLIANCE TO ENSURE CORRECT PERFORMANCE

AND CARRY OUT ANY NECESSARY ADJUSTMENTS

AS DETAILED IN SECTION 1.

After carrying out any servicing or exchange of

gas carrying components - 

ALWAYS CHECK FOR GAS TIGHTNESS!

3.1 GAS CONVERSION CHECK LIST

CHANGE MAIN INJECTORS

CHANGE PILOT INJECTORS

MODIFY MULTIFUNCTIONAL CONTROL

CHANGE DATA PLATE

CHANGE CROSS LIGHTING INJECTOR

To convert from Natural to Propane gas, remove

regulator mechanism. Replace with blanking plate that is

supplied with kit.

To convert from Propane to Natural gas, remove blanking

plate. Replace with regulator mechanism supplied in kit.

All relevant injectors to be changed to suit gas type.

Pressure must also be adjusted to suit gas type.

Refer to Section 1.9.

Summary of Contents for G3830

Page 1: ...to the User having had a demonstration of the operation and cleaning of the Appliance IT IS MOST IMPORTANT THAT THESE INSTRUCTIONS BE CONSULTED BEFORE INSTALLING AND COMMISSIONING THIS APPLIANCE FAILURE TO COMPLY WITH THE SPECIFIED PROCEDURES MAY RESULT IN DAMAGE OR THE NEED FOR A SERVICE CALL PREVENTATIVE MAINTENANCE CONTRACT In order to obtain maximum performance from this unit we would recommen...

Page 2: ...ion systems Gas water and electrical supply external to unit Light bulbs Re installing vacuum in kettle jackets Replacement of grill burner ceramics when damage has been clearly caused by misuse Where an engineer finds no fault with a product that has been reported faulty Re setting or adjustment of thermostats when unit is operating to specification Cleaning and unblocking of fryer filter systems...

Page 3: ...between the rear and sides of the fryer and any combustible wall If the floor is constructed of combustible material then local fire requirements should be checked to ensure compliance Important If appliance is to be installed in suite formation with other matching units the instructions for all models must be consulted to determine the necessary clearances to any combustible rear wall or overlyin...

Page 4: ...d be accessible to operator from front or side 2 3 CONNECTION TO A GAS SUPPLY Gas supply piping and unit connection must be installed in accordance with regulations listed on front page of this document A gas isolating cock must be fitted to the supply in a position that is readily accessible to operator 2 4 CONNECTION TO AN ELECTRICAL SUPPLY Not applicable to these units 2 5 CONNECTION TO A WATER...

Page 5: ...njector 3 3 2 Removal of Pilot Cross Lighting Injectors Isolate main gas supply Undo pilot cross lighter supply pipe compression nut and remove pipe from pilot cross lighter burner Withdraw injector Replace in reverse order 3 4 FLAME FAILURE THERMOCOUPLE Undo nuts at pilot assembly and valve body Disconnect thermocouple interrupter from terminal block 2 7 INSTRUCTION TO USER After installing and c...

Page 6: ...ostat phial Disconnect thermostat electrical connections prior to removing thermostat Replace in reverse order 3 6 2 Recalibration of User Thermostat Remove knob from thermostat spindle taking care not to rotate it in either direction as this would change setting Steady spindle and rotate calibration screw clockwise to decrease and anti clockwise to increase the temperature 3 6 3 Checking the User...

Page 7: ...SECTION 4 SPARES When ordering spare parts always quote unit type and serial number This information will be found on data badge attached to base plate ...

Page 8: ......

Reviews: