1.8 INJECTOR SIZE
1.8.1 Natural Gas 

1.8.2 Propane Gas

1.8.3 Cross-Lighting Burners

1.9 GAS PRESSURE ADJUSTMENT

1.9.1 Supply Pressures

A pressure test point is fitted on the burner manifold and

the operating pressure is shown in the tables below.

On G3865 model, burner pressure should be set with

both pans turned on.

An adjustable governor is included in the multifunctional

control on Natural Gas models.

Supply Pressure

1.9.2 All Models 

Burner Pressure

1.10 BURNER ADJUSTMENTS

1.10.1 Pilot

An adjustment screw is located on the multifunctional

control to regulate pilot flame. Adjust pilot screw to

provide a flame approximately ¾" long, projecting from

each pilot burner channel. A flame larger than this will roar

excessively.

Main Burner

No aeration adjustment is necessary, however gas

pressure should be set as per value shown in Section 1.9.

Gas type

mbar

inches w.g

Natural Gas

20

8

Propane Gas

37

14.8

SECTION 2 - 
ASSEMBLY and COMMISSIONING

2.1 ASSEMBLY

The unit is packed as a complete assembly, except the

flue. To fit this, slide flue over upstand on hob rear and

secure with fixings along lower front and rear edges.

Slot basket hanger over knurled nuts and hand-tighten.

2.2 APPLIANCES ON CASTORS

For units on castors, refer to guidelines in BS6173.

These state that where wheels, castors or rollers are

used, these must be fitted with a brake or locking device.

This should be accessible to operator from front or side.

2.3 CONNECTION TO A GAS SUPPLY

Gas supply piping and unit connection must be installed

in accordance with regulations listed on front page of this

document.

A gas isolating cock must be fitted to the supply in a

position that is readily accessible to operator.

2.4 CONNECTION TO AN ELECTRICAL SUPPLY

Not applicable to these units.

2.5 CONNECTION TO A WATER SUPPLY

Not applicable to these units.

2.6 PRE-COMMISSIONING CHECK

Prior to operation, ensure that all packing material has

been removed from unit.

2.6.1 Setting The Gas Pressure

a) It is necessary to check gas pressure during

commissioning. A suitable pressure gauge must be

connected to test point on supply manifold.

b) Turn on main gas valve at supply.

c) Light burners as detailed in User Instructions.

The  supply pipes may contain air therefore it may be

necessary to repeat lighting procedure.

d)  Adjust multifuncional control pressure governor to

relevent settiing as detailed in Section 1.9 of this

document. The screw should be turned clockwise to

increase pressure and anti-clockwise to reduce it.

Check again after 15 minues of operation.

e) Disconnect pressure gauge from test point.  Replace

sealing screw and test gas soundness.

Model

Pilot Burner

Main Burner

G3830 Fryer

NG No. 18

Ø2.38mm

G3860 Fryer

NG No. 18

Ø3.2mm

G3865 Fryer

NG No. 18

2 x Ø2.38mm

Natural

Propane

NG No. 26

LP No. 16

Model

Pilot Burner

Main Burner

G3830 Fryer

LP No. 11

Ø1.57mm

G3860 Fryer

LP No. 11

Ø2.15mm

G3865 Fryer

LP No. 11

2 x Ø1.57mm

Gas type

mbar

inches w.g

Natural Gas

15

6

Propane Gas

34.5

13.8

Summary of Contents for G3830

Page 1: ...to the User having had a demonstration of the operation and cleaning of the Appliance IT IS MOST IMPORTANT THAT THESE INSTRUCTIONS BE CONSULTED BEFORE INSTALLING AND COMMISSIONING THIS APPLIANCE FAILURE TO COMPLY WITH THE SPECIFIED PROCEDURES MAY RESULT IN DAMAGE OR THE NEED FOR A SERVICE CALL PREVENTATIVE MAINTENANCE CONTRACT In order to obtain maximum performance from this unit we would recommen...

Page 2: ...ion systems Gas water and electrical supply external to unit Light bulbs Re installing vacuum in kettle jackets Replacement of grill burner ceramics when damage has been clearly caused by misuse Where an engineer finds no fault with a product that has been reported faulty Re setting or adjustment of thermostats when unit is operating to specification Cleaning and unblocking of fryer filter systems...

Page 3: ...between the rear and sides of the fryer and any combustible wall If the floor is constructed of combustible material then local fire requirements should be checked to ensure compliance Important If appliance is to be installed in suite formation with other matching units the instructions for all models must be consulted to determine the necessary clearances to any combustible rear wall or overlyin...

Page 4: ...d be accessible to operator from front or side 2 3 CONNECTION TO A GAS SUPPLY Gas supply piping and unit connection must be installed in accordance with regulations listed on front page of this document A gas isolating cock must be fitted to the supply in a position that is readily accessible to operator 2 4 CONNECTION TO AN ELECTRICAL SUPPLY Not applicable to these units 2 5 CONNECTION TO A WATER...

Page 5: ...njector 3 3 2 Removal of Pilot Cross Lighting Injectors Isolate main gas supply Undo pilot cross lighter supply pipe compression nut and remove pipe from pilot cross lighter burner Withdraw injector Replace in reverse order 3 4 FLAME FAILURE THERMOCOUPLE Undo nuts at pilot assembly and valve body Disconnect thermocouple interrupter from terminal block 2 7 INSTRUCTION TO USER After installing and c...

Page 6: ...ostat phial Disconnect thermostat electrical connections prior to removing thermostat Replace in reverse order 3 6 2 Recalibration of User Thermostat Remove knob from thermostat spindle taking care not to rotate it in either direction as this would change setting Steady spindle and rotate calibration screw clockwise to decrease and anti clockwise to increase the temperature 3 6 3 Checking the User...

Page 7: ...SECTION 4 SPARES When ordering spare parts always quote unit type and serial number This information will be found on data badge attached to base plate ...

Page 8: ......

Reviews: