background image

G3830, G3860, G3865 Fryers

INSTALLATION and 
SERVICING INSTRUCTIONS

This appliance must be installed and serviced by a competent person as stipulated by the
Gas Safety (Installation & Use) Regulations.

IMPORTANT

The installer must ensure that the installation of the appliance is in conformity with these instructions
and National Regulations in force at the time of installation. Particular attention MUST be paid to:

Gas Safety (Installation & Use) Regulations
Health And Safety At Work etc. Act
Local and National Building Regulations
Fire Precautions Act

The appliance has been CE-marked on the basis of compliance with the Gas Appliance Directive for
the Countries, Gas Types and Pressures as stated on the data plate.

WARNING

TO PREVENT SHOCKS, ALL APPLIANCES WHETHER GAS OR ELECTRIC, 

MUST BE EARTHED.

On completion of the installation, these instructions should be left with the Engineer-in-Charge for
reference during servicing. Further to this, The Users Instructions should be handed over to the User,
having had a demonstration of the operation and cleaning of the Appliance.

IT IS MOST IMPORTANT THAT THESE INSTRUCTIONS BE CONSULTED BEFORE INSTALLING
AND COMMISSIONING THIS APPLIANCE. FAILURE TO COMPLY WITH THE SPECIFIED
PROCEDURES MAY RESULT IN DAMAGE OR THE NEED FOR A SERVICE CALL.

PREVENTATIVE MAINTENANCE CONTRACT

In order to obtain maximum performance from this unit we would recommend that a maintenance
contract be arranged with 

SERVICELINE

. Visits may then be made at agreed intervals to carry out

adjustments and repairs. A quotation will be given upon request to the contact numbers below.

WEEE Directive Registration No. WEE/DC0059TT/PRO

At end of unit life, dispose of appliance and any replacement 
parts in a safe manner, via a licenced waste handler.
Units are designed to be dismantled easily and recycling of all 
material is encouraged whenever practicable.

Falcon Foodservice Equipment

HEAD OFFICE AND WORKS

Wallace View, Hillfoots Road, Stirling. FK9 5PY. Scotland.

SERVICELINE CONTACT

Phone: 01438 363 000

Fax: 01438 369 900

T100760 Ref.1

Detailed recommendations are contained in
Institute of Gas Engineers published documents:
IGE/UP1, IGE/UP/2
BS6173 and BS5440

Summary of Contents for G3830

Page 1: ...to the User having had a demonstration of the operation and cleaning of the Appliance IT IS MOST IMPORTANT THAT THESE INSTRUCTIONS BE CONSULTED BEFORE INSTALLING AND COMMISSIONING THIS APPLIANCE FAILURE TO COMPLY WITH THE SPECIFIED PROCEDURES MAY RESULT IN DAMAGE OR THE NEED FOR A SERVICE CALL PREVENTATIVE MAINTENANCE CONTRACT In order to obtain maximum performance from this unit we would recommen...

Page 2: ...ion systems Gas water and electrical supply external to unit Light bulbs Re installing vacuum in kettle jackets Replacement of grill burner ceramics when damage has been clearly caused by misuse Where an engineer finds no fault with a product that has been reported faulty Re setting or adjustment of thermostats when unit is operating to specification Cleaning and unblocking of fryer filter systems...

Page 3: ...between the rear and sides of the fryer and any combustible wall If the floor is constructed of combustible material then local fire requirements should be checked to ensure compliance Important If appliance is to be installed in suite formation with other matching units the instructions for all models must be consulted to determine the necessary clearances to any combustible rear wall or overlyin...

Page 4: ...d be accessible to operator from front or side 2 3 CONNECTION TO A GAS SUPPLY Gas supply piping and unit connection must be installed in accordance with regulations listed on front page of this document A gas isolating cock must be fitted to the supply in a position that is readily accessible to operator 2 4 CONNECTION TO AN ELECTRICAL SUPPLY Not applicable to these units 2 5 CONNECTION TO A WATER...

Page 5: ...njector 3 3 2 Removal of Pilot Cross Lighting Injectors Isolate main gas supply Undo pilot cross lighter supply pipe compression nut and remove pipe from pilot cross lighter burner Withdraw injector Replace in reverse order 3 4 FLAME FAILURE THERMOCOUPLE Undo nuts at pilot assembly and valve body Disconnect thermocouple interrupter from terminal block 2 7 INSTRUCTION TO USER After installing and c...

Page 6: ...ostat phial Disconnect thermostat electrical connections prior to removing thermostat Replace in reverse order 3 6 2 Recalibration of User Thermostat Remove knob from thermostat spindle taking care not to rotate it in either direction as this would change setting Steady spindle and rotate calibration screw clockwise to decrease and anti clockwise to increase the temperature 3 6 3 Checking the User...

Page 7: ...SECTION 4 SPARES When ordering spare parts always quote unit type and serial number This information will be found on data badge attached to base plate ...

Page 8: ......

Reviews: