1
3
Condition - The filtration pump
(where fitted)
is not working.
(Refer to Figure 5)
Action 1
- Burner ON/OFF control must be switched to OFF before pressing filter pump switch.
Action 2
- The oil suction pipe has become blocked. Clean it and dry thoroughly.
Note:
This is caused by debris in the bottom of oil bucket. The microfilter and strainer have not been cleaned or have
been damaged.
This can cause unfiltered oil to overflow into the oil bucket.
Action 3
- The pipework has become blocked
(refer to Action 2)
or has been inserted incorrectly into one of the
quick release connections.
Action 4 -
The oil is too hot. Pump is fitted with a thermal safety device. This must be allowed to cool before pressing
reset switch directly below pump on base panel.
A
B
C
D
E
J
I
F
H
K
Key to components
Figure 5
A Oil return pipe
B Flue quick release connection
C Internal filter pipework
D Strainer basket
E Suction pipe
F Oil pump
G Oil decant hose (not illustrated)
H Pump motor
I Micro filter
J Suction pipe filter
K Oil bucket
Summary of Contents for G2844F