e) Carefully place the plaques on their support bars

with the pips pointing downward. Ensure they are

properly located and that they lay flat on the bars.

f) Replace the inner top panel and ensure that it is

properly positioned and located over the cast iron

compartment sides.

g) Replace the outer top panel.

2.2 CONNECTION TO THE GAS SUPPLY
Installation should be carried out in accordance with

the various regulations listed on the cover of this

document.
On NATURAL gas appliances, the adjustable

governor supplied, MUST be fitted to the gas circuit

and securely fixed in a position which enables

adjustment to be carried out during commissioning.

PROPANE appliances do not require a governor.
Ensure that a gas Isolating cock is fitted to the supply

at a convenient proximity to the grill.

2.3 CONNECTION TO AN ELECTRICAL SUPPLY
Not applicable to this appliance.

2.4 CONNECTION TO A WATER SUPPLY
Not applicable to this appliance.

2.5 COMMISSIONING
2.5.1 Testing and Purging
Pressure test the gas installation for soundness and

purge any air from the supply.
2.5.2 Gas Pressure and Burner Flame Adjustment
a) Remove the RH Side Panel.
b) Fit a suitable pressure gauge tothe test point and

light the grill.

c) On NATURAL gas appliances, with the burner at

the FULL FLAME position, the setting pressure

should be 15mbar (6 inches w.g.). Adjust the

governor as required.

d) With the gas control in the FULL FLAME position,

check that the flame cone is approximately 30mm

in length. If necessary, adjust by means of the

aeration screw in the burner throat. Tighten the

locknut when complete.

e) Check that all burner parts CROSS LIGHT

satisfactorily.

f) Turn the control to the LOW FLAME position and

check that the flame cone reduces in length.

Note
LOW FLAME position is set at factory. Re-setting is

NOT necessary.
2.5.3 Soundness Checking and Re-assembly
Whilst the grill is lit, test all integral gas carrying joints

and components for soundness. Use a suitable leak

detection fluid (i.e. Soap Solution).
TURN OFF the gas control tap. REMOVE the

pressure gauge and replace the test point sealing

screw.
ENSURE THAT A GAS TIGHT JOINT IS MADE.
Re-assemble all panels and components removed

during the installation and commissioning. The drip

tray, wire grid and brander can then be placed in

position.

2.6 INSTRUCTION TO USER
Hand over the Users Instruction manual. Ensure that

the user understands the procedures for lighting,

cleaning and correct use of appliance. Point out the

location of the isolating cock which may require to be

shut down in event of an emergency.

SECTION 3 - SERVICING and

CONVERSION

Important
Before carrying out any inspection, servicing or

exchange of components, turn OFF the gas at the

isolating cock and take steps to ensure that it is not

inadvertently turned on. Always remove the brander

and grid shelf.
After any maintenance task, check the appliance to

ensure that it performs correctly and carry out any

necessary adjustments as detailed in Section 1.
After carrying out any servicing or exchange of gas

carrying components -
ALWAYS CHECK FOR GAS SOUNDNESS!

3.1 GAS CONVERSION CHECK LIST
To convert from NATURAL to PROPANE gas -
Change injectors
Remove the governor and adjust the inlet pressure

accordingly
Adjust aeration
Change Data Plate
To convert from PROPANE to NATURAL gas -
Change injectors
Connect a governor and adjust the inlet pressure

accordingly
Adjust aeration
Change Data Plate

Summary of Contents for G1532

Page 1: ...be left with the Engineer in Charge for reference during servicing Further to this The Users Instructions should be handed over to the User having had a demonstration of the operation and cleaning of...

Page 2: ...harges vertically from the top of the unit There must be no direct connection of the flue to a mechanical extraction system or the outside air Positioning the grill below a ventilated canopy is the mo...

Page 3: ...st below Brander Drip Trough Brander Plate Grid Shelf Drip Tray Gas Governor Natural Gas only Additionally 6 refractory plaques 4 centre support bars of double construction and 4 end support bars Appl...

Page 4: ...crew positions Remove the shelf and d r i l l t h e w a l l t o accomodate suitable plugs for No 8 screws Firmly secure the shelf in position Place the grill on the shelf and place screws through hole...

Page 5: ...rner parts CROSS LIGHT satisfactorily f Turn the control to the LOW FLAME position and check that the flame cone reduces in length Note LOW FLAME position is set at factory Re setting is NOT necessary...

Page 6: ...vidual ports may be cleared with a suitable metal instrument Dislodged material should then be shaken out of the open burner end Should it become necessary to wash the burner s ensure that they are co...

Page 7: ...er with Pilot 3 8 GOVERNOR 3 8 1 General The governor will normally require little servicing Before proceeding with any inspection or servicing TURN OFF THE GAS AT THE ISOLATING COCK 3 8 2 Procedure C...

Reviews: