Falcon Fusion Installation and Operation Manual
14
Ÿ
Wait until the Falcon Fusion has re-connected to the GSM
network on the new SIM card and displays the signal strength.
Ÿ
If the Falcon Fusion displays an error message (E1 or E4), the
selected SIM card is not working and the other one should be
selected
Ÿ
The minimum signal strength required is 5. Lower than this
signal strength will make it difficult to access the Falcon
Fusion remotely
3.5 Selecting the Alarm Panel Serial Port Format
The alarm panel serial port can be selected via the onboard
push-button (as well as the PC-based programming software).
The following serial port formats are available:
Ÿ
Rhino 816 and Rhino 68 alarm panels
Ÿ
Texecom premier range (panel uploads and downloads can
also be done)
Ÿ
Paradox SP & MG Series
Ÿ
Pima
Ÿ
IDS
Ÿ
DSC PowerSeries Neo
Ÿ
Sherlotronics MB4000
Ÿ
DSC PowerSeries
Ÿ
IDS805 FSK Key-Bus