28
INSTALLATION
Check the appliance is electrically safe and gas sound when you have finished.
Australia
�
To convert the governor, snap the device out of the
top and refit it the other way up. The snap-in converter
device is marked to show the gas for which it is set:
Natural gas
Propane gas
Make sure the device is secure in the top cap and refit
the cap to the governor.
Stick on label
Stick the appropriate label on to the data badge to
indicate the gas for which the appliance is now set.
Propane Pressure Testing
Connect the appliance to the gas supply. Ensure that the
appliance is gas sound.
The gas pressure can be measured at one of the left
hand hotplate burner jets. Lift off a burner head. Fit the
pressure gauge to the jet. Turn on the hotplate burner
and turn on and light one of the other burners.
Re-assemble the burner top, making sure that it is re-
assembled in the correct way on the burner body.
Refit the control tap shield. Reconnect the wiring to the
control panel and refit the panel.
Check that the appliance is both electrically safe and
gas sound.
Check the operation of all the burners.
Electrical Connection
This appliance must be installed by a qualified
electrician to comply with the relevant regulations
(in particular AS/NZS 60335.2.6:2002), and also the
local electricity supply company requirements.
Ensure that the mains characteristics (voltage, nominal,
power, etc.) match the ratings indicated on the data
plate affixed to the cooker.
The cooker is preset for a single-phase earthed electrical
connection. It is essential to install a multi-pole circuit
breaker that completely disconnects the appliance from
the mains, with a minimum contact break distance of
3mm.
WARNING: THIS APPLIANCE MUST BE EARTHED
The appliance must be connected to an efficient
earthing circuit. If the electricity network is not
equipped with an earth connection, then it must
be installed separately in compliance with local
regulations.
Earthing is a safety measure required by law,
and must be performed with particular care by a
qualified technician, who must also check that the
electricity supply characteristics are correct.
The cable size used should be suitable for the appliance
load and in accordance with local regulations. Please
note that the maximum cable sizes are 6mm
2
for the
screw terminals.
Access to the mains terminal is gained by removing the
electrical terminal cover box on the back panel. Connect
the mains cable to the correct terminals for your
electrical supply type.
You may need to move the links to suit your connection
type. Check that the links are correctly fitted and that
the terminal screws are tight. Secure the mains cable
using the cable clamp.