![Falcon Elan User Manual Download Page 27](http://html.mh-extra.com/html/falcon/elan/elan_user-manual_539770027.webp)
27
Australia
INSTALLATION
Check the appliance is electrically safe and gas sound when you have finished.
another hose, it is still mandatory to fit the stability
bracket and restraining chain.
After completing the gas connection, ensure that
the cooker is gas sound with a pressure test (see the
following sections).
When checking for gas leaks, do not use washing up
liquid - this can corrode. Use a product specifically
manufactured for leak detection.
Natural Gas
The adjustable spring loaded governor is pre-set to give
a nominal pressure of 1kPa on NG. Connect to the Rp
1/2 inlet on the underside of the governor (just above B
on the previous figure).
Pressure testing for Natural Gas
Pull the cooker forward, if necessary, to gain access to
the rear of the cooker. The gas pressure test point is
accessible on the connector block that comes out of the
governor at the top rear of the cooker.
Remove the test nipple screw and fit a pressure gauge
to the test point. Turn on and light two of the hotplate
burners.
See the data badge and the
Technical Data
section at
the back of this book for test pressures.
Conversion from Natural Gas to
LP Gas
Check in the Technical Data section at the back of
the book that the cooker is convertible to the type
of LPG (Liquid Petroleum Gas) that you want to use,
typically Propane.
This cooker is supplied ready for use on natural gas.
A conversion kit for propane gas is supplied with the
cooker. Any conversion to propane must be performed
by a competent person. Following conversion, the
installation must comply with the relevant regulations
and also the local electricity supply company
requirements.
Read the instructions before converting the
appliance. Failure to convert the appliance correctly
could invalidate any warranty or liability claims and
lead to prosecution.
Before servicing or replacing gas-carrying
components, disconnect the cooker from the gas
connection before commencing operation. You
should also disconnect it from the electricity supply
to allow the servicing of items that connect to the
electricity supply, e.g. the fascia panel.
Do not use re-conditioned or unauthorised gas
controls.
Jets
Standard burner Wok burner
A jet, B internal injector, C external injector
Remove the burner caps and heads. Remove the old jets
and then fit the new jets. Re-assemble in reverse order.
Tap Adjustment
Pull off all the control knobs.
If the hand rail has
been fitted, remove it
by removing the plastic
blanking plugs, followed by
the two end bracket fixing
screws.
Remove the two cross-
headed screws that were
hidden by the hand rail
end brackets.
Open the oven door and grill door and remove the
fixing screws underneath the control panel.
Lower the fascia panel clear of the top retaining tags.
Turn the bypass screw on each gas control clockwise to
the stop:
A tap bypass screw
Set the Governor
Unscrew the governor's brass top. There is a plastic
snap-in converter device in the base of the brass top: