4.0 SPECIFICATION
4.1
This unit is suitable for AC supplies only
4.2
The standard terminal arrangement is Three phase (400V 3N~) for all variants.
4.3
To convert the appliance from three phase to single phase supply, insert links
between phases 1, 2 and 3. Consideration must be given to required draw of current.
THIS APPLIANCE MUST BE EARTHED.
Live 1 ( Phase 1)
Brown
Live 2 ( Phase 2)
Black
Live 3 ( Phase 3)
Grey
Neutral
Blue
Earth
Yellow/Green
E9541, E9541CR, E9541R
Phase
Min
Max
Actual (A)
L1
8.6
10.03
9.56
L2
8.6
10.03
9.56
L3
E9581, E9581CR, E9581R
Phase
Min
Max
Actual (A)
L1
8.6
10.03
9.56
L2
17.2
20.07
19.12
L3
8.6
10.03
9.56
IF ANY CURRENT IS OUT WITH THESE TOLERANCES, THE
CAUSE MUST BE INVESTIGATED AND RECTIFIED.