8.0 FAULT FINDING
FAULT
POSSIBLE CAUSES
REMEDY
No power (red neon
extinguished)
Appliance disconnected from
mains power
Reconnect to mains power
No heat when thermostat
turned on (amber neon
extinguished)
Appliance internal fuse blown Investigate reason, rectify
fault, replace fuse
Faulty thermostat
Replace
Safety thermostat tripped
Reset/investigate reason
No heat when thermostat
turned on (amber neon
illuminated)
Faulty contactor
Replace
Faulty element
Replace
Appliance not hot enough
Faulty thermostat
Replace.
Note:
when checking plate
temperature, probe 210mm
in from each side halfway
between front and rear on
E9581 models. Probe centre
plate on E9541 models
9.0 SPARE PARTS
Mains Pilot light RED
730962010
Circuit Pilot light AMBER
730962040
Element 230V
733620006
Thermostat E9581/81R/41/41R
731910500
Thermostat E9581CR/41CR
733630002
Safety thermostat E9581CR/41CR
733630003
Control knob E9581/81R/41/41R
733620005
Control Knob E9581CR/41CR
733630004
When ordering spares, quote the following:
Model Number
Serial number
Gas Type
This information is found on data plate on front panel. (see section 1.0)
Visit our website for further spares information.
Summary of Contents for E9541
Page 9: ...9 5 0 DIMENSIONS CONNECTION LOCATIONS...
Page 11: ...11 6 2 2 Connect appliance to mains supply...
Page 20: ...20 7 7 CIRCUIT DIAGRAMS 7 7 1 E9541 E9541R...
Page 21: ...21 7 7 2 E9541CR...
Page 22: ...22 7 7 3 E9581 E9581R...
Page 23: ...23 7 7 4 E9581CR...
Page 24: ...24 7 8 WIRING DIAGRAMS 7 8 1 E9541 E9541R...
Page 25: ...25 7 8 1 E9541CR...
Page 26: ...26 7 8 1 E9581 E9581R...
Page 27: ...27 7 8 1 E9581CR...