6.2 VENTILATION
This appliance must be installed with sufficient ventilation to prevent the occurrence of
unacceptable concentrations of substances harmful to health in the room in which they are
installed. Installer must consult any additional local / national regulations.
COMBUSTION AIR REQUIREMENTS
APPLIANCE
G20
G31
G3845 26
m
3
/h 26
m
3
/h
G3845F 26
m
3
/h 26
m
3
/h
6.3 ASSEMBLY
6.3.1 Position the appliance and level using feet adjusters as shown below.
TAKE CARE WHEN MOVING AN APPLIANCE FITTED WITH
CASTORS.
6.3.2 Connect appliance to gas supply and test for gas tightness (see section 6.4)
This appliance is also provided with a terminal for connection of an
external equipotential conductor. This terminal is an effective electrical
contact with all fixed exposed metal parts of the appliance, and shall
allow the connection of conductor having a nominal cross-section area
of up to 10mm². It is located at the rear of the unit and identified by the
following label and must only be used for bonding purposes.