Falcon DOMINATOR PLUS E3830 Design, Installation And Servicing Instructions Download Page 6

3.1 

ELECTRICAL CONTROL GEAR

 

The mains terminals are located at rear of unit. The contactor(s) are contained within a box at the front. 

To gain access, open door and remove cover panel behind. 

The control thermostat(s) and neon lamps are mounted on the facia panel, which is secured by four fixings. 

 

3.2 

NEON INDICATOR LAMPS

 

These must be replaced by new lamps in event of failure.

 

To replace a faulty lamp, first remove facia panel and pull  off push-on terminals. Remove lamp by undoing 

fixing nut  at rear.

 

 

3.3 

THERMOSTATS

 

The fryer has two thermostats. 
The adjustable control thermostat is mounted upon control panel. 
The safety thermostat is located within the element box. It has a fixed setting and manual re-set button at 
rear of element box. In the event of control thermostat failure and resultant overheating of frying medium, 
safety thermostat will trip supply to elements before oil temperature becomes dangerous. 
To   restore    circuit    having    rectified    the    fault, it is necessary to press the re-set button. This is 
situated within the turret which projects through element box rear. The oil must be allowed to cool to 
enable safety thermostat to be re-set. 
A defective safety or control thermostat cannot be repaired and must be replaced. The capillary tubes 
pass through pan wall and are sealed with small glands which must not be overtightened. The phial must 
be fixed in position within pan before tightening gland. The phial tip should protrude from protective tube 
by 33mm. Thermostat capillary tube must be covered with sleeve insulation. Safety stat phial should be 
located centrally within element clip. 
 
 
 

 

3.4 

CONTACTOR

 

This should require little or no maintenance under normal  circumstances.  After  long  service,  the  contacts 

may become pitted and at that point, new contacts should  be fitted. 

 

3.5 

ELEMENTS

 

These are individually replaceable. Access to terminals and fixing nuts is gained upon removing element 

box  cover.  When  fitting  a  new  element,  ensure  that  sealing  gasket is fitted and tighten fixing nut firmly, 

preferably with  the aid of a tubular box spanner or socket.

 

When  re-fitting  element  box  cover,  check  condition  of  oil  resistant  gasket.  Do  not  use  excessive  force 
when  securing cover as this may deform it and allow oil to enter  box. 

3.6 

CLEANLINESS

 

To maintain maximum performance, the pan must be kept  clean.  Periodically,  oil  must  be  drained  off  and 

the pan  should be filled with water and detergent. Boil up contents  and drain whilst still hot before flushing 

out with clean  water. Thoroughly dry pan and all fittings before re-filling  with oil. The elements can be lifted 

and hinged backward  to gain full access to all surfaces of pan and elements.

 

 

3.7 

TILT SWITCH

 

Located in element terminal box, this component should  require no maintenance.

 

 

 

 

 

 
 

 

 

Summary of Contents for DOMINATOR PLUS E3830

Page 1: ...stration of the operation and cleaning of the appliance IT IS MOST IMPORTANT THAT THESE INSTRUCTIONS BE CONSULTED BEFORE INSTALLING AND COMMISSIONING THIS APPLIANCE FAILURE TO COMPLY WITH THE SPECIFIE...

Page 2: ...connector must meet the specification requirements of IEC 60947 Your attention is drawn to BS 7671 2018 Guidance Note 8 8 13 Other locations of increased risk It is recognized that there may be locati...

Page 3: ...it is designed for use on AC supplies only and terminals are arranged for either 2 phase operation E3830 model or 3 phase E3860 E3865 models Cable entry is located at appliance rear in the form of a c...

Page 4: ...cal connections Undo cable gland Feed cable through cable gland into electrical box Connect leads to respective terminals Tighten cable gland Replace cover 2 3 COMMISSIONING Fill pan s with oil to mar...

Page 5: ...Falcon for a warranty issue dial UK only 01786 455 200 and select Warranty Issues from the menu BEFORE ATTEMPTING ANY MAINTENANCE TASK ISOLATE THE APPLIANCE AT THE MAIN SUPPLY TAKE STEPS TO ENSURE THA...

Page 6: ...and are sealed with small glands which must not be overtightened The phial must be fixed in position within pan before tightening gland The phial tip should protrude from protective tube by 33mm Ther...

Page 7: ...TION 4 SPARES When ordering spares quote the unit type and serial number This information will be found on data plate located on cover panel behind door An identity label is also provided on front fra...

Page 8: ...E3830 WIRING DIAGRAM...

Page 9: ...E3830 CIRCUIT DIAGRAM...

Page 10: ...E3860 WIRING DIAGRAM...

Page 11: ...E3860 CIRCUIT DIAGRAM...

Page 12: ...E3865 WIRING DIAGRAM...

Page 13: ...E3865 CIRCUIT DIAGRAM...

Reviews: