SECTION 1 

– INSTALLATION 

 

 

UNLESS OTHERWISE STATED, PARTS WHICH HAVE BEEN PROTECTED BY THE 
MANUFACTURER ARE NOT TO BE ADJUSTED BY THE INSTALLER. 

 

 
Please ensure that any plastic coatings are removed prior to use. Before operation, the pan 
requires to be thoroughly cleaned and dried. 
Discolouration of heated parts is caused by factory testing to ensure a satisfactory unit. It does 
not affect quality or performance. 
 

1.1 MODEL NUMBERS, NETT WEIGHTS  and DIMENSIONS 

 

Model

 

Width

 

(mm)

 

Depth

 

(mm)

 

Height

 

(mm)

 

Weight

 

(kg)

 

E3830 Fryer

 

300

 

770

 

890

 

45

 

E3860 Fryer

 

600

 

770

 

890

 

73

 

E3865 Fryer 

600 

770 

890 

85 

 

1.2 

SITING

 

Before connecting appliance to electricity supply, it must be correctly positioned and levelled. 
Levelling is affected by turning the lower area of the adjustable legs. If desired, feet that allow 
floor-fixing may be specified at time of order. 

 

1.3 

ELECTRICAL CONNECTION

 

The unit is designed for use on AC supplies only and  terminals are arranged for either 2 phase  operation 

(E3830 model) 

or 3 phase 

(E3860 & E3865 models)

.

 

Cable entry is located at appliance rear in the form of a  cable gland.

 

A suitably rated isolating switch with contact separation of  at least 3mm in all poles must be installed. All wiring 

must  be executed in accordance with regulations listed on title  page of this document. 

 

  

This appliance must be earthed. 

 

 

Check that no damage has occurred to the appliance and power cable during transit. If damage has 

occurred do not use the appliance. 

Ensure that the mains power cable is routed free from the appliance to avoid damage. 

We recommend supplementary electrical protection with the use of a type A residual current device 

(RCD). Periodical testing, repair and fixing wiring connection should only be undertaken by a skilled 

and competent electrician. 

 

1.4 

ELECTRICAL RATINGS

 

The electrical rating is stated on appliance data plate.

 

 

Model 

L1 

L2 

L3 

E3830 Fryer 

21.7A 

21.7A 

 

E3860 Fryer 

31.7A  15.85A 

31.7A 

E3865 Fryer 

21.7A 

43.5A 

21.7A 

Summary of Contents for DOMINATOR PLUS E3830

Page 1: ...stration of the operation and cleaning of the appliance IT IS MOST IMPORTANT THAT THESE INSTRUCTIONS BE CONSULTED BEFORE INSTALLING AND COMMISSIONING THIS APPLIANCE FAILURE TO COMPLY WITH THE SPECIFIE...

Page 2: ...connector must meet the specification requirements of IEC 60947 Your attention is drawn to BS 7671 2018 Guidance Note 8 8 13 Other locations of increased risk It is recognized that there may be locati...

Page 3: ...it is designed for use on AC supplies only and terminals are arranged for either 2 phase operation E3830 model or 3 phase E3860 E3865 models Cable entry is located at appliance rear in the form of a c...

Page 4: ...cal connections Undo cable gland Feed cable through cable gland into electrical box Connect leads to respective terminals Tighten cable gland Replace cover 2 3 COMMISSIONING Fill pan s with oil to mar...

Page 5: ...Falcon for a warranty issue dial UK only 01786 455 200 and select Warranty Issues from the menu BEFORE ATTEMPTING ANY MAINTENANCE TASK ISOLATE THE APPLIANCE AT THE MAIN SUPPLY TAKE STEPS TO ENSURE THA...

Page 6: ...and are sealed with small glands which must not be overtightened The phial must be fixed in position within pan before tightening gland The phial tip should protrude from protective tube by 33mm Ther...

Page 7: ...TION 4 SPARES When ordering spares quote the unit type and serial number This information will be found on data plate located on cover panel behind door An identity label is also provided on front fra...

Page 8: ...E3830 WIRING DIAGRAM...

Page 9: ...E3830 CIRCUIT DIAGRAM...

Page 10: ...E3860 WIRING DIAGRAM...

Page 11: ...E3860 CIRCUIT DIAGRAM...

Page 12: ...E3865 WIRING DIAGRAM...

Page 13: ...E3865 CIRCUIT DIAGRAM...

Reviews: