Technical Data
This cooker is designed for use on Natural Gas:-
A
conversion
for
LP
(LPG X Propane (2.75kPa)) gas is available.
.
INSTALLER: Please leave these instructions with the User.
DATA BADGE LOCATION : LOWER RIGHT HAND COOKER UPRIGHT (Remove storage drawer)
Country of Destination: Australia
Gas
Electric
Natural Gas
1kPa
220 - 240V 50Hz
Propane
2.54kPa
(See appliance data badge for test pressures)
Dimensions
Overall height
minimum 893mm
maximum 920mm
Overall width
1100mm See ‘Positioning of Cooker’
Overall depth
648mm
Space for fixing
See ‘Positioning of Cooker’
Minimum space above hotplate
650mm
Connections
Gas:
Electric
Rp 1/2 at rear right-hand side
220 - 240V 50Hz
Ratings
Natural Gas 1.0kPa
L.P. Gas 2.54kPa
Hotplate
Injector
Bypass
Injector
Bypass
Wok burner
15.2MJh
-1
internal 112
90
15.0MJh
-1
internal 66
54
external 164
external 91
Large Burner
12.3MJh
-1
165
80
12.0MJh
-1
89
41
Medium Burners
6.2MJh
-1
115
56
6.2MJh
-1
67
33
Small Burner
3.7MJh
-1
92
48
3.3MJh
-1
45
25
Gas burner inputs based on Gross Calorifi c Value
Ovens
Conventional
Forced air convection
Oven
Browning Element
Oven
2.2kW
1.15kW
2.5kW
Grill
2.3kW
Warmer
160W
Maximum total electrical load at 230V