Falcon 100LT User, Installation And Servicing Instructions Download Page 16

16

 

 

2.6.1 TROUBLESHOOTING 

Warning!

 Only qualified service personnel can perform the operations described below! 

Warning!

 Before resetting safety thermostat, it is always necessary to eliminate the problem 

causing its activation (only for models with indirect heating)! 

Problem and possible cause 

Access to components and operation 

The content of the pan does not heat: 

 

Safety thermostat has been activated. 

Pilot burner is on but main burners do 
not light: 

 

loss of pressure in gas supply; 

 

clogged injectors on main burners. 

Pilot burner does not light: 

 

clogged injectors on pilot burner; 

 

faulty ignition plug; 

 

check the cable of the ignition plug. 

Pilot burner does not remain lit: 

 faulty 

thermocouple; 

 

partially clogged injector on pilot burner;

 

faulty magnet in control. 

Safety thermostat 

The safety thermostat can be accessed by removing lower 
front panel when the two side screws have been undone.  

 
Main burners 

Remove lower front panel. 
 

Pilot burner 

Remove lower front panel. Pilot burner is located in front of 
combustion chamber.   
 

Ignition plug and  thermocouple

 

Remove lower front panel.

 

  

 

3.1 WARNINGS AND HINTS FOR USER 

This manual contains all the instructions required for a proper and safe use of our 
appliances. 

Keep the manual in a safe place for future consultation! 

This appliance is for catering use and must be used only by trained kitchen staff. 

The appliance must always be kept under observation during use and never left unattended 

Warning!

 The manufacturer shall not be held responsible for injuries or damage due to non-

compliance with safety rules or improper use of appliance by the operator.  

Some improper operating conditions may even be caused by an improper use of the 
appliance, therefore it is important to train personnel properly. 

All the installation and maintenance operations must be performed by fitters who are 
members of an official register. 

Respect the periods required for maintenance. With this is mind, customers are 
recommended to sign a service agreement with Serviceline. 

In case of failures concerning the appliance, all supplies (gas and water) must be isolated 
immediately. In the case of recurrent failure, contact a service technician. 

Always turn off products at the end of service.  

Never add water to hot oil as an explosion may occur. 

Summary of Contents for 100LT

Page 1: ...F900 SERIES User installation and servicing instructions BOILING PAN G9781 Read these instructions before use T100915 REV 5 DATE PURCHASED MODEL NUMBER SERIAL NUMBER DEALER SERVICE PROVIDER...

Page 2: ...iance and any replacement parts in a safe manner via a licensed waste handler Appliances are designed to be dismantled easily and recycling of all material is encouraged whenever practicable Dear Cust...

Page 3: ...e health and safety of all users For further help and information on training and competence we would refer you the Health and Safety Executive website www hse gov uk document ref health and safety tr...

Page 4: ...Only competent persons are allowed to service or convert the appliance to another gas type Gas appliances must have a stop cock fitted in the supply pipe work The user must be familiar with the locat...

Page 5: ...ol of the gas inlet pressure 13 2 3 2 Control of primary air flow 13 2 4 Commissioning and testing 14 2 5 Conversion to other types of gas 14 2 5 1 Replacement of injectors for main burners 14 2 5 2 R...

Page 6: ...1 Size of appliance and position of connections 20 4 2 Measuring the inlet pressure 21 4 3 Gas cock 22 4 4 Pilot burner 23 4 5 Main burner 24 4 6 Primary air regulation 24 4 7 Controls 25 4 8 Relief...

Page 7: ...urfaces can become hot and require special operation Unplug the appliance in case of failures or improper operation Apply exclusively to a service centre for repairs or maintenance All important infor...

Page 8: ...ndirect 135 0 5 150LT A Pressure Kettle Indirect 135 0 05 0 5 Table 2 Sizes Refer to Section 4 1 Specifications Models Description Unit of measurement 100LT 150LT Width A mm 800 Depth B mm 900 Height...

Page 9: ...ADJUST Primary air distance G20 mm 30 G30 G31 Table 6 Gas inlet pressure Table 6a Nominalmainpressureforthedifferenttypesof gas Gas family 2 Natural 20 mbar Gas family 3 LPG 28 30 36 mbar Table 6b Ope...

Page 10: ...le that cuts off the gas flow if the pilot burner should turn off for any reason The water connection is 3 4 The appliance is equipped with a mixer tap 1 3 1 SPECIAL FEATURES FOR PRESSURE KETTLES Stai...

Page 11: ...agency electricity board regulations concerning safety the regulations of the electrical power supply company or agency any other local prescriptions 1 5 SPECIAL REQUIREMENTS FOR THE INSTALLATION SIT...

Page 12: ...ts stated in the technical data plate if the appliance has been designed for these supplies 2 2 1 CONNECTION TO WATER SUPPLY Water inlet pressure must be between 50 and 300 kPa otherwise install a pre...

Page 13: ...ssure is measured using a liquid pressure gauge e g a U shaped pressure gauge minimum definition 0 1 mbar The supply pressure can be measured directly at the inlet pressure intake on the gas feed pipe...

Page 14: ...they are expelled without any hindrance The test report must be completed in full and submitted to the customer who should then sign in acceptance With effect from this moment the appliance is covere...

Page 15: ...connection on the injector tube see figure Measuring gas pressure Set the output pressure of the gas cock according to the figures stated in table 4 Minimum output setting After setting seal the adjus...

Page 16: ...lug and thermocouple Remove lower front panel 3 1 WARNINGS AND HINTS FOR USER This manual contains all the instructions required for a proper and safe use of our appliances Keep the manual in a safe p...

Page 17: ...T MOD 100 150LT Warning The jacket water level must be checked each time before lighting Warning It is advised that softened water is used to fill the jacket Open level tap at appliance front Undo fil...

Page 18: ...by setting knob to maximum heating position When pan reaches cooking temperature turn knob to low position to maintain cooking temperature End of cooking turning off main burner and pilot burner Turn...

Page 19: ...and isolate all supplies gas and water Apply to a service centre for help The manufacturer shall not be held responsible nor has any warranty commitments for damage caused by non compliance with pres...

Page 20: ...20 4 1 MODEL DIMENSIONS S Overflow A Water connection 3 4 G Gas connection R in conformity with ISO 7 1...

Page 21: ...21 4 2 MEASURING INLET PRESSURE A Inlet pressure intake B Outlet pressure intake A B...

Page 22: ...OCK A Thermocouple nut B Gas output C Outlet pressure intake D Inlet pressure intake E Rated output adjustment screw F Gas inlet G Gas connection for pilot burner H Minimum output adjustment screw B C...

Page 23: ...23 4 4 PILOT BURNER A Thermocouple B Pilot burner C Ignition plug D Injector E Tightness screw...

Page 24: ...24 4 5 MAIN BURNER A Burner B Injector C Injector pipe B C A 4 6 PRIMARY AIR REGULATION H...

Page 25: ...25 4 7 CONTROLS A Knob C OFF position D Minimum position E Maximum position F Pilot flame position A C F D E 4 8 RELIEF VALVE Pressure Kettle Only Operating position Open position...

Reviews: