Q: How does an Extractor Fan work?
A: 

Extractor fans are designed to remove

 

airborne grease, steam, heat smoke and odours from cooking by

extracting and filtration of the air in your kitchen and above your cooking surface.

6.

Q: Are my downlights/bulbs covered under the warranty period?
A: 

NO. Downlights, bulbs, aluminium and Charcoal filters and are not covered under the guarantee period.

For the full list of terms and condition of the warranty period please read the warranty certificate supplied
inside the box or in your manual. You can also download it from 

www.falco.co.za

7.

Q: How often do I have to replace my filters?
A: 

With daily use we recommend that you replace your charcoal filters every 6 months. Your aluminium filters

can be cleaned in luke warm water and dishwashing liquid. Please do not put your aluminium filters in the
dishwasher as this will discolour the filters and they will become dull. Alternatively you just purchase new
aluminium filters.

8.

Q: How long is my warranty and what does it entail?
A: 

All our extractor fans carry a two year guarantee. Motors, PC Boards, Capacitors, Transformers (for units

with 12volt downlights), 220Volt light sockets(for units with normal 220v light bulbs), Main Control Switches
and motor fan blades are covered by our two year parts and labour guarantee.

9.

Q: What is excluded from my warranty?
A: 

Downlights and bulbs, Glass panels and extractor glass, aluminium and charcoal filters are excluded from

the warranty.

10. Q: How do I clean my Stainless steel extractor?

A: 

Always ensure your extractor is cleaned with non-abrasive cleaners. Always read the product instructions

and ensure that the product is safe for the use of Stainless steel. Two great products are window cleaner,
which is also a stainless steel cleaner, and spray on wood polish, another certified stainless steel cleaner.
Please note that abrasive cleaners will damage the stainless steel and will cause rust or rust stains.

11. Q: Why is there rust marks on my extractor?

A: 

Stainless steel can rust if cleaned with abrasive cleaners. The chemicals inside abrasive cleaners react

with the stainless steel and the result will be rust.

 

There are many day to day cleaning products in our kitchens

that are abrasive cleaners and unknown to the consumer. Please make sure you read the instructions and if
Stainless Steel is not mentioned, then do not use the product on Stainless steel.

12. Q: Can I extend my stainless steel chimneys if they are to short?

A: 

Yes.  Please make sure of your measurements before starting your installation process. Additional bottom

chimneys and installation brackets are sold by Lategan & Van Biljoens in Pretoria and they are used to extend
the chimneys on Falco units.

13. Q: My extractor is blowing and not extracting?

A: 

There are three main reasons that can cause your extractor to blow instead of extracting and most of the

time (98%), this is caused by faulty installations. Please make sure that there is no obstruction on top or inside
your ducting hose. 

The yellow warning sticker placed over the ducting outlet should be removed after

installation is completed to ensure no debris falls into the cavity, damaging the extractor barrel fan.

Make sure the power cable is neatly secured inside the chimneys and make sure the power cable is not
causing an obstruction on top of your butterfly valve. Poor workmanship and failure to secure the power cable
causes the cable to lie on top of the butterfly valve and this will block and prevent the unit from extracting
properly.

13

Summary of Contents for AR-60-903BL

Page 1: ...INSTALLATION AND USER MANUAL MODELS AR 60 903BL AR 60 903SS AR 90 903BL AR 90 903SS...

Page 2: ...full providing that the product appliance is located no further than 50km from an authorised service agent Where the product appliance is located beyond the 50km radius the purchaser shall be liable...

Page 3: ...e incorrect size Extractor Fan is installed above any electrical or gas hob Example of such an installation is installing a 600mm Extractor above a 900mm gas or electrical hob 14 This warranty does no...

Page 4: ...4 Table of Contents INTRODUCTION 5 SAFETY PRECAUTIONS 5 INSTALLATION 5 AIR VENTILATION SETTING 7 OPERATION 8 MAINTENANCE 9 TROUBLESHOOTING 11 FREQUENTLY ASKED QUESTIONS 12 ENVIRONMENTAL PROTECTION 15...

Page 5: ...void any fire hazards due to oil build up in and around the extractor If the supply cord is damaged it must be replaced by the manufacturer or qualified service agent to avoid electrical hazards Only...

Page 6: ...an electrical hob or cooker 65cm but not exceeding 75cm Drawing B OPTION 1 Installing with no cupboard above the unit 1 Drill 2 x 8mm holes into the wall once you have determined a suitable position...

Page 7: ...the cupboard by using the screws to attached the unit through the 4 x pre drilled holes at the top of the unit Note The ducting pipe as depicted in the above picture is not supplied with the unit AIR...

Page 8: ...ll then be vented out the front of the unit Please note that the cloth carbon filter is affixed to the back of the aluminum filters and needs to be replaced every three months Warning If using this ex...

Page 9: ...THLY CLEANING OF THE GREASE FILTER ALUMINIUM Clean the filter monthly to prevent fire hazards due to oil build up The aluminium filters collect oil so their cleanliness directly affects the extractor...

Page 10: ...Switch off the unit and unplug 2 Remove the lamp cover 3 Unscrew the incandescent bulb 4 Replace with the same type and rated bulb Tungsten filament lamp tubular Max wattage 28 W Voltage range 230 V...

Page 11: ...ug in to the power supply again Serious Vibration of the unit The fan blade is damaged Switch off the unit and repair by qualified service agent The fan motor is not fixed tightly Switch off the unit...

Page 12: ...ove gas and 650mm above electrical On either application it is recommended that your installation height does not exceed 750mm to ensure the best results Q Do I require a recirculation kit A No The ex...

Page 13: ...e for the use of Stainless steel Two great products are window cleaner which is also a stainless steel cleaner and spray on wood polish another certified stainless steel cleaner Please note that abras...

Page 14: ...rate of your extractor fan If you are out venting the air and the extension of ducting hose exceeds 2 5meter you need to purchase an addition extraction motor that must be installed in line with the d...

Page 15: ...e environment and human health which could otherwise be caused by inappropriate waste handling of this product The symbol on the product indicates that this product may not be treated as household was...