background image

Please be careful when removing and installing the Island installation Brackets and Stainless Steel chimneys. 
The Stainless steel chimneys contains sharp edges and can possibly lead to cuts. 

Generally asked Questions and Answers: 

1.

Q: My extractor fan is not extracting
A: 

before logging a service call please ensure the installation on your extractor fans was done properly to

avoid a service call out fee charge. Herewith a list of commonly found mistakes on everyday installations:
* Installer did not remove the tape on the butterfly valve. (Q: 13).

*

Installer did not secure the power cord inside the chimney. (Q: 13).

*

Your ducting hose is exceeding the recommended maximum length. (Q: 13).

*

Your unit is not at the recommended height. (Q: 3).

*

Your unit is installed above the wrong application. (Q: 2).

A service fee will apply when we log a service call and any of the points above apply.

2.

Q: Can I use the extractor fan above my gas braai?
A: 

NO. Please note that this unit was designed for the intended purpose of domestic kitchens only and cannot

be used as a commercial extractor fan. Commercial usage includes but is not limited to: Restaurants, Coffee
Shops, Soup Kitchens, Tuck shops, Food trailers, Gas 

braai’s inside or outside your property, any other form

of braai and any kitchen that is used for commercial purposes. Using the extractor you purchased on any
commercial application poses a serious fire risk and will result in immediate void of your warranty. Please
contact our Falco offices for assistance with Gas Braai Extractors.

3.

Q: What is the correct installation height?
A: 

The recommended installation height is 700mm above gas and 650mm above electrical. On either

application it is recommended that your installation height does not exceed 750mm to ensure the best results.

Q: Do I require a recirculation kit? 
A: 

No. The extractor was designed to be used on both applications; External and Re-circulation air operation 

and no additional kit are required.  

4.

Q: What is the difference between External and Re-circulation air operation?
A: Re- circulation; 

All wall mount units are supplied with aluminium and charcoal filters. For Re-circulation

mode you will simply install the unit. The air will filtrate through both sets of filters, you’re outside aluminium
filters 

and

 

you’re inside charcoal filters.

 

The air discharged from your extractor is then clean and grease free

and cannot cause any damage. There are two options when using your extractor on Re-circulation. 1 

– Let the

filtrated air escape through the vents on top of your top chimney or you can use the extendable ducting house
to vent the air into your ceiling.

 

Activated charcoal

 in the charcoal filters removes odour and some smoke

particles from the air before releasing the cleaned air back into the kitchen.

External: 

The only difference between Re-circulation mode and external mode is that on external mode you

are venting the air to the outside of your property using a ducting hose. This means the clean filtrated air will
not be discharged into your kitchen or ceiling but to the outside. The unit is supplied with an extendable
ducting hose. When venting your air outwards the charcoal filters can be removed to improve the suction rate.
Removing the charcoal filters on re-circulation mode is not recommended.
|

Please note that the wall fitting that fits into your wall when venting your air outwards is not supplied
with the extractor and can be purchased locally.

12

Summary of Contents for AR-60-903BL

Page 1: ...INSTALLATION AND USER MANUAL MODELS AR 60 903BL AR 60 903SS AR 90 903BL AR 90 903SS...

Page 2: ...full providing that the product appliance is located no further than 50km from an authorised service agent Where the product appliance is located beyond the 50km radius the purchaser shall be liable...

Page 3: ...e incorrect size Extractor Fan is installed above any electrical or gas hob Example of such an installation is installing a 600mm Extractor above a 900mm gas or electrical hob 14 This warranty does no...

Page 4: ...4 Table of Contents INTRODUCTION 5 SAFETY PRECAUTIONS 5 INSTALLATION 5 AIR VENTILATION SETTING 7 OPERATION 8 MAINTENANCE 9 TROUBLESHOOTING 11 FREQUENTLY ASKED QUESTIONS 12 ENVIRONMENTAL PROTECTION 15...

Page 5: ...void any fire hazards due to oil build up in and around the extractor If the supply cord is damaged it must be replaced by the manufacturer or qualified service agent to avoid electrical hazards Only...

Page 6: ...an electrical hob or cooker 65cm but not exceeding 75cm Drawing B OPTION 1 Installing with no cupboard above the unit 1 Drill 2 x 8mm holes into the wall once you have determined a suitable position...

Page 7: ...the cupboard by using the screws to attached the unit through the 4 x pre drilled holes at the top of the unit Note The ducting pipe as depicted in the above picture is not supplied with the unit AIR...

Page 8: ...ll then be vented out the front of the unit Please note that the cloth carbon filter is affixed to the back of the aluminum filters and needs to be replaced every three months Warning If using this ex...

Page 9: ...THLY CLEANING OF THE GREASE FILTER ALUMINIUM Clean the filter monthly to prevent fire hazards due to oil build up The aluminium filters collect oil so their cleanliness directly affects the extractor...

Page 10: ...Switch off the unit and unplug 2 Remove the lamp cover 3 Unscrew the incandescent bulb 4 Replace with the same type and rated bulb Tungsten filament lamp tubular Max wattage 28 W Voltage range 230 V...

Page 11: ...ug in to the power supply again Serious Vibration of the unit The fan blade is damaged Switch off the unit and repair by qualified service agent The fan motor is not fixed tightly Switch off the unit...

Page 12: ...ove gas and 650mm above electrical On either application it is recommended that your installation height does not exceed 750mm to ensure the best results Q Do I require a recirculation kit A No The ex...

Page 13: ...e for the use of Stainless steel Two great products are window cleaner which is also a stainless steel cleaner and spray on wood polish another certified stainless steel cleaner Please note that abras...

Page 14: ...rate of your extractor fan If you are out venting the air and the extension of ducting hose exceeds 2 5meter you need to purchase an addition extraction motor that must be installed in line with the d...

Page 15: ...e environment and human health which could otherwise be caused by inappropriate waste handling of this product The symbol on the product indicates that this product may not be treated as household was...

Page 16: ......

Reviews: