10. Manufacturer Specific Report.
11. Description of signals - light-emitting diode (LED)
Motor operating status (see figure no.1)
Z-Wave operating status (see figure no.1)
Singular blink of the
diode
The current received from the motor
is too low.
Continuous
lighting of the
diode
The appliance does not belong to any network -
remove control is impossible. This diode always
appears when the appliance is connecting to a new
motor. It disappears when the appliance is linked
to any network using “INCLUDE” function.
Triple blink of the
diode
The current received from the motor
is too intensive. A calibration of the
awning blind motor should be
checked. A description of outskirts
regulation is described in point A of
the awning blind installation.
02.03.18 NC97B-GB 7/8 ©2018, FAKRO
0x0085
0x0005
0x0012
Manufacturer Specific Report
Parameter
Value
Manufacturer ID
Product Type ID
Product ID