background image

Note

1.

 Wires deeper than the detection limit from surface, in 

    conduit or behind plywood shear wall will not be 

    detected use caution when using the detector under 

    these circumstances.

2.

 Rubbing or banging the unit on the wall may generate 

    static electricity and cause a false indication.

3.

 Leakage Currents

    Because of the extremely small current required to 

    cause a reading on the detector, an apparent false 

    reading may be seen in some situations, If a live wire 

    with poor insulation is touching a damp wall, the detector 

    will show a voltage on the walls surface In this situation, 

    the detector is indicating a potential hazard which should 

    be checked using a voltmeter.

9

Summary of Contents for FAI DET31

Page 1: ......

Page 2: ...d identify a stud centre 3 Find AC voltage and scan to trace live cables 4 Metal scanning to find nails pipes rebar and other hidden metal objects This detector may be used to carry out the following...

Page 3: ......

Page 4: ...urn the detector on You must depress and hold this switch down to calibrate the detector or when you wish to perform detection operation 6 Selector switch A three position switch used to select the re...

Page 5: ...roughout all the following procedures 3 Detection a Place the detector on the surface and slowly move the unit sideways fig 1 When the detector moves closer and closer to the stud the signal LEDs will...

Page 6: ...en performing a calibration the detector will not work correctly 3 The surface of wall along which you want to detect should be flat and dry 4 We recommend that you also carry out a metal detection sc...

Page 7: ...he unit moves closer and closer to a metallic object the signal LEDs will light sequentially fig 1 When the top signal LED lights and the buzzer sounds continuously the unit detects the metallic objec...

Page 8: ...etector on the surface and slowly move the unit sideways fig 1 When the top signal LED lights and buzzer sound continuously stop moving the detector has located the edge of a live wire mark a spot in...

Page 9: ...ate static electricity and cause a false indication 3 Leakage Currents Because of the extremely small current required to cause a reading on the detector an apparent false reading may be seen in some...

Page 10: ...id unexpected problems please be aware that different types of material may be close together A stud joist pipe metal object or wire may be adjacent to each other 4 If you do not intend to use the det...

Page 11: ...wall texture paint etc Operation condition 7 40 C below 75 RH Storage condition 20 50 C below 85 RH Battery 9V 6F22 or equivalent Dimension 163 x 74 x 26mm Weight approx164g including battery Stud mod...

Page 12: ...eplace the battery door correctly Depleted batteries should be disposed of at your local recycling facility 12 DISPOSAL OF THIS PRODUCT Dear Customer If you at some point intend to dispose of this art...