background image

FAIRCHILD T7800 STANDARD RANGE

MINIATURE ELECTRO-PNEUMATIC TRANSDUCER

Installation, Operation and Maintenance Instructions

Figure 1. 

Model T7800 Standard Range Transducer Identification Number System 

Identification Number 

Non-incendive (Division 2) approval on FM voltage 

input units only. 

Intrinsically Safe approval, including non-incendive 

(Division 2), on 4-20 mA units only. 

Electrical Connections 

Underwriting Group 

Approval Class 

Input 

Output 

1/2 NPT Conduit 

Fitting with Pigtail 

Terminal Block 

DIN 43650 Connection 

Rack Mount 

Factory Mutual 

Canadian Standard 

ATEX 

Intrinsically Safe 

Non-Incendive (Division 2) 

4-20mA 

1-5 VDC 

0-5 VDC 

1-9 VDC 

0-10 VDC 

3-15 psig 

3-27 psig 

6-30 psig 

[0.2-1.0 BAR] 

[0.2-1.8 BAR] 

[0.4-2.0 BAR] 

(20-100 kPa) 

(20-180 kPa) 

(40-200 kPa) 

(A) 

(T) 

(D) 

(R) 

( )  

(N) 

I

 

(4) 

(5) 

(7) 

(9) 

(0) 

(F) 

(C) 

(E) 

(01) 

(02) 

(03) 

(11) 

(12) 

(13) 

(21) 

(22) 

(23) 

Select appropriate psig, [BAR] or (kPa). 

7800 ­

GENERAL INFORMATION

The Model T7800 Series of Electro-Pneumatic Trans­
ducer converts a DC input signal to a linearly proportional 
pneumatic output pressure. 

SPECIFICATIONS 

Minimum 
Span 

3-15 

[0.2-1.0] 

(20-100) 

4-20 mA DC, 0-10 VDC, 

1-9 VDC, 0-5 VDC, 1-5 VDC 

20-120 

[1.5-8.0] 

(150-800) 

[0.35] 

(35) 

3-27 

[0.2-1.8] 

(20-180) 

10 

[0.7] 

(70) 

32-120 

[2.2-8.0] 

(220-800) 

6-30 

[0.4-2.0] 

(40-200) 

35-120 

[2.4-8.0] 

(240-800) 

10 

[0.7] 

(70) 

psig 

[BAR] 

(kPa) 

psig 

[BAR] 

(kPa) 

psig 

[BAR] 

(kPa) 

Functional Specifications 

Output 
Range 

Supply 
Pressure 

Input 
Range 

A i r   C o n ­
s u m p t i o n  

Set Point 

3 psig 

[0.2 BAR] 

(20 kPa) 

9 psig 

[0.6 BAR] 

(60 kPa) 

15 psig 

[1.0 BAR] 

(100 kPa) 

30 psig 

[2.0 BAR] 

(200 kPa) 

All Ranges 
(SCFH) 

3.5 

(.10 m  /HR) 

7.0 

(.20 m  /HR) 

9.5 

(.27 m  /HR) 

13.5 

(.38 m  /HR) 

Flow Rate 
( S C F M )  

2.5 (4.25m  /HR) @ 

25 psig, [1.7 BAR], 

(170 kPa) supply & 

9 psig, [0.6 BAR], 

(60 kPa) output. 

9.0 (15.3m  /HR) @ 

120 psig, [8.0 BAR], 

(800 kPa) supply & 

9 psig, [0.6 BAR], 

(60 kPa) output. 

or 

Temperature 
Range 

Operating . . . . . . . . . . . . . . . . . . . . .  

Storage . . . . . . . . . . . . . . . . . . . . .  

-40  F to +180  F 
(-40  C to +82.2  C) 

-40  F to +160  F 
(-40  C to +71.2  C) 

S  p a n / Z e r o  
Adjustments 

Screwdriver adjustments located on front 

of unit 

Required 
Operating 
Vo l ta g e s  

Two Wire Current Input 

7.2 VDC @ 20 mA (4-20 mA signal) 

Supply 
Voltage 

Three Wire Voltage Input 

7-30 VDC, less than 3 mA 

S i g n a l  
Impedance 

Three Wire Voltage Input 

10 Kilohms 

Summary of Contents for T7800 Series

Page 1: ...DC input signal to a linearly proportional pneumatic output pressure SPECIFICATIONS Minimum Span 3 15 0 2 1 0 20 100 4 20 mA DC 0 10 VDC 1 9 VDC 0 5 VDC 1 5 VDC 20 120 1 5 8 0 150 800 5 0 35 35 3 27...

Page 2: ...ltage input units TDFI7800 TAFI7800 TDFN7800 TAFN7800 Class I Division 2 Groups A B C and D Class II Division 2 Groups F and G Class III Division 2 NEMA 4X Enclosure Temperature Code T4 TTFI7800 TRFI7...

Page 3: ...umalloy Inrare cases igntion sources due to impact and friction sparks couldoccur Thisshallbeconsideredwhentheequipment is installed in locations that specifically require Group II category1Gequipment...

Page 4: ...Installation continued Figure 6 TR7800 Outline Dimensions Figure 5 TD7800 Outline Dimensions Figure 4 TT7800 Outline Dimensions 4...

Page 5: ...Figure 8 Optional Mounting Kit 19254 1 sold separately Figure 7 Din Rail Mounting Kit 16893 1 included with unit 5...

Page 6: ...tream to avoid interference with transducer performance The user is responsible for ensuring that the environmentinwhichtheunit isinstalledand the operating gas are compatible with the materials in th...

Page 7: ...desiredoutputrangeis obtained SPLIT RANGEOPERATION Lo Hi Span Adjustment 1 Set the Lo Hi Span switch to the Lo position for 3 9 psig or 9 15 psig output range and for 4 20 mA input range Set the Lo Hi...

Page 8: ...Calibrations Adjustments continued Figure 10 T7800CalibrationConfiguration 8...

Page 9: ...11 1 12 1 13 14 15 16 17 1 18 19 Qty Cover Machining Screw Screw Gasket Nozzle Body Assembly Orifice Assembly Spring Disk Diaphragm Spacer Ring Diaphragm Assembly Foam Block Valve Body Assembly Screw...

Page 10: ...n with alcohol and dry with compressed air NOTES 1 Parts must be completely dry before reassembling 2 If the standard maintenance procedure does not correct the problem install the appropriate service...