8.
Remove the heat exchanger grille by unscrewing
the 4 star screws.
9.
Remove the right and left flue gas inspection plates
by unscrewing hexagonal screws with hexagonal
or tube wrenches. Use a screwdriver, if necessary,
to remove the siliconized dowels.
10.
To remove soot and scratches beat in the front
and top area with a rubber hammer or similar as
shown in the picture.
11.
Insert a pipe cleaner inside of inspections to
precipitate the soot adhered to the smoke motor.
12.
Use the ash aspirator with the 2 open inspection
doors.