FagronLab™ PRO DMS – User Manual  |  4

1. Introduction

2. Service

3. Warranty

Thank you for purchasing the digital magnetic hotplate stirrer FagronLab™ PRO-DMS. This manual contains important 
operating and safety information. You must carefully read and understand the contents of this manual prior to operating 
this device.

In case of any problem, you can always contact the Service Department for technical support. Please provide the customer 
care representative with the following information:

  Serial number (on the rear panel).

 Certification.

  Description of problem.

  Methods and procedures adopted to resolve the problems.

  Your contact information.

This device is under warranty and free from defects in materials and workmanship, under normal use and service, for a 
period of 24 months from the date of invoice. The warranty is extended only to the original purchaser. Warranty is not 
valid on device which has been damaged on account of improper installation, improper connections, misuse, accident or 
abnormal conditions of operation.

For claims under the warranty please contact your local supplier. 

FagronLab™ PRO-DMS

Summary of Contents for FagronLab PRO-DMS

Page 1: ...FagronLab PRO DMS User Manual www fagronlab com ...

Page 2: ......

Page 3: ...l and custom use 6 8 Control 7 Control elements 7 Control panel 7 Display 8 9 Function 8 Heating 8 Working with external temperature sensor 9 Residual heat warning HOT 9 10 Stirring 9 11 Remote control 10 12 Faults 10 13 Maintenance and cleaning 11 14 Associated standards and regulations 11 15 Specifications 12 Table of contents ...

Page 4: ...ive with the following information Serial number on the rear panel Certification Description of problem Methods and procedures adopted to resolve the problems Your contact information This device is under warranty and free from defects in materials and workmanship under normal use and service for a period of 24 months from the date of invoice The warranty is extended only to the original purchaser...

Page 5: ...of the Periodic Table of Elements will have chemical reaction with PTFE when temperature reaches 300 400 C Check the device and accessories prior to each use Do not use damaged components Safe operation is only guaranteed with the accessories described in the Accessories chapter Accessories must be securely attached to the device and can not come off by themselves Always disconnect the plug before...

Page 6: ...e that the required operating voltage matches with the power supply voltage Ensure that the socket is properly grounded Plug in the power cable ensure the power is on and begin initializing Add the medium into the vessel with an appropriate stirring bar Place vessel on the work plate Set the desirable stirring speed Set the desirable temperature Stop both heating and stirring functions If these op...

Page 7: ...b stir Set the rated rotary speed The function stirring is switched ON or OFF via pushing ON OFF the knob Heating knob heat Set the rated temperature The function heating is switched ON or OFF via pushing ON OFF the knob LCD display LCD displays the real working state and all settings LED heat When the heating function is switched ON the LED Heat is lit LED stir When the stirring function is switc...

Page 8: ...ature of the sample 9 Function Figure 4 Device display Note If both heating and stirring functions have been started at the same time heating function always has higher priority If in this case speed is changed via the stirring knob it displays stirring speed and reverses to temperature in the duration of 5 seconds Characters Description Temp and C Display temperature when the heating function is ...

Page 9: ...tically switch off If users want to turn off the LCD immediately just unplug the power cable When the power cable is pulled out the residual heat warning function cannot be visual 10 Stirring The function stirring is switched on or off via pushing the stirring knob The speed can be set by the knob 100 to 1500 rpm in steps of 10 rpm When both of functions heating and stirring are switched on the LC...

Page 10: ...contact supplier The unit can be controlled from an external PC using the dedicated software via the RS232C serial interface fitted to the unit Data communication from laboratory device to computer is only possible on demand of the computer The functions of the interface lines between laboratory device and automation system are selected from the specified signals of the EIA standard RS232C corresp...

Page 11: ... and place it in a stable dry room temperature and clean location 13 Maintenance and cleaning Proper maintenance can keep the device working properly and lengthen its lifetime Do not spray cleanser into the device when cleaning Unplug the power cable when cleaning Only use recommended cleansers to maximize the life of your FagronLab PRO DMS device Before using other method for cleaning or decontam...

Page 12: ...ry speed display LCD Plate material Stainless steel Ceramic coated Dimensions of workplate mm Ø 135 Heating power W 500 Temperature range C RT 340 increment 1 Temperature display C LCD Temperature display accuracy C 0 1 The safe temperature of hotplate C 360 Temperature sensor in medium PT1000 Control accuracy of heating temp with temp sensor C 0 2 Residual heat warning 50 C Device Dimensions LxWx...

Page 13: ...FagronLab PRO DMS Notes ...

Page 14: ...FagronLab PRO DMS Notes ...

Page 15: ......

Page 16: ...Together we create the future of personalized medicine Fagron Hellas 12 km N R Trikala Larisa P C 42100 P O Box 32 Trikala Greece T 30 24310 83633 5 F 30 24310 83615 www fagron gr P R OD M SU M 0 1 ...

Reviews: