ENGLISH
VISUAL INSTRUCTION MANUAL
37
E3 Sensor TV
DESCRIPTION:
Steam probe broken.
TV out of range [-5..330]
CONSEQUENCES:
It is only possible to operate in
Convection
mode, omitting water condensation.
E4 Sensor TG
DESCRIPTION:
Gas probe broken.
TG out of range [-5..330]
CONSEQUENCES:
It is only possible to operate in
Convection
mode
E5: Water Level
DESCRIPTION
Water is detected at the maximum level but not at the minimum level.
CONSEQUENCE
It is only possible to operate in
Convection
mode
E6: Calibration Error
DESCRIPTION
It was not possible to calibrate in 15 minutes.
CONSEQUENCE
The oven continues to function normally
.
E7: Error A.E.
DESCRIPTION
The variator frequency input (A.E.) has been observed not to function.
•
The connection has been cut off
•
If the motor does not start within 10 seconds of a start request.
•
If a speed of 500 rpm is not exceeded within 20 seconds of a start request.
CONSEQUENCE
The oven is completely disabled
E8: Needs water
DESCRIPTION
The VDV is observed to have been running for 7 or more minutes and the maximum
level has not been reached.
CONSEQUENCE
It is only possible to operate in
Convection
mode
E9: Err. Drainage