Fagor FMD-49 Manual For Installation, Use And Maintenance Download Page 3

www.fagorcommercial.com

 

Page

3

 

 

 

MERCHANDSERS OPERATION AND SERVICE MANUAL/ Rev. JUN. 2015

 

 

1

 

RECEIVING AND INSPECTING THE EQUIPMENT 

 

Up on receiving your new Fagor Refrigerator, check the package and the machine for any 
damages  that  may  have  occurred  during  transportation.  Visually  inspect  the  exterior of 
the  package.  I f  damaged,  open  and  inspect  the  contents  with  the  carrier.  Any  damage 
should be noted and reported on the delivering carrier’s receipt. 
In  the  event  that  the  exterior  is  not  damaged,  yet  up  on  opening,  there  is  concealed 
damage  to  the  equipment  notify,  the  carrier  immediately.  Notification  should  be  made 
verbally as well as in written form. Request an inspection by the shipping company of the 
damaged equipment. Retain all crating material until inspection has been made. Contact 
the dealer through which you purchased the unit. 

 

Check  the  compressor  compartment  thousing  and  visually  inspect  the  refrigeration 
package. Be sure lines are secure and base is still intact. 
 
 
 

A NOTE FROM OUR QUALITY CONTROL MANAGER 
 
CONGRATULATIONS  ON  YOUR  NEW  PURCHASE.  WE  WOULD  LIKE  TO 
WELCOME  YOU  TO  THE  FAGOR  TEAM.  THE  UNIT  IN  FRONT  OF  YOU  IS  A 
GREAT  PIECE  OF  EQUIPMENT  THAT  WILL  BECOME  ONE  OF  YOUR  MOST 
RELAIBLE TOOLS IN YOUR DAILY OPERATIONS FOR YEARS TO COME! 
PRIOR  TO  SHIPPING  YOUR  UNIT,  OUR  TRAINED  SERVICE  TECHNICIANS 
TESTED  YOUR  UNIT  FOR  A  PERIOD  OF  12  HOURS.  THIS  PERFORMANCE 
TEST  WAS  RECORDED  AND  A  COPY  OF  THE  RESULTS  IS  INCLUDED  WITH 
THIS  SERVICE  MANUAL.  DURING  THIS  TEST,  OUR  HIGHLY  QUALIFIED 
PERSONNEL INSPECTED YOUR MACHINE FOR  LEAKS, LOSE COMPONENTS, 
AND  IMPROPER  NOISE  LEVELS.  WE  ALSO  TESTED  THE  COOLING 
PERFORMANCE IN AN EFFORT TO GIVE YOU THE BEST AND MOST RELAIBLE 
UNIT POSSIBLE. 

 

Summary of Contents for FMD-49

Page 1: ...MERCHANDISER REFRIGERATORS AND FREEZERS Manual for installation use and maintenance...

Page 2: ...TIONS 4 3 DIMENSIONS 6 4 INSTALLATION 9 4 1 UNCRATING 9 4 2 LOCATION 9 4 3 DATA PLATE 10 4 4 ELECTRICAL CONNECTIONS 11 4 5 SHELVING INSTALLATION 11 5 OPERATION 12 5 1 ELECTRONIC CONTROLLER 12 6 MAINTE...

Page 3: ...material until inspection has been made Contact the dealer through which you purchased the unit Check the compressor compartment thousing and visually inspect the refrigeration package Be sure lines...

Page 4: ...tion Line Super Heat BTU Ref Amount Ref Type Ship Weight Set Point Cut in FM 10 10 4 0 C 32 F 5 C 41 F 10 16 PSIG 7 C 13 F 1400 9 8 oz R 134a 203 FM 16 16 4 0 C 32 F 5 C 41 F 10 16 PSIG 7 C 13 F 1800...

Page 5: ...2P TT 15 amp 10 amp 14 AWG 14 AWG 14 AWG 14 AWG 12 AWG 14 AWG 12 AWG 14 AWG 12 AWG 14 AWG 10 AWG 12 AWG FM 16 1 4 115 220 5 8 3 4 5 15P 2P TT 15 amp 10 amp 14 AWG 14 AWG 14 AWG 14 AWG 12 AWG 14 AWG 12...

Page 6: ...www fagorcommercial com Page6 MERCHANDSERS OPERATION AND SERVICE MANUAL Rev JUN 2015 3 DIMENSIONS FM 10 FM 16...

Page 7: ...www fagorcommercial com Page7 MERCHANDSERS OPERATION AND SERVICE MANUAL Rev JUN 2015 FMD 23 FDM 49...

Page 8: ...www fagorcommercial com Page8 MERCHANDSERS OPERATION AND SERVICE MANUAL Rev JUN 2015 FMD 47 SD FMD 37 SD...

Page 9: ...ity is higher than 60 the door frames may sweat water This is not a malfunctioning of the unit WARNING The following actions will void your warranty Modification of power cord Connecting the unit to a...

Page 10: ...it The data plate is essential to identify the particular features of your machine and it is of great benefit to installers operators and maintenance personnel It is recommended that in the event the...

Page 11: ...ordance with NEC Article 422Appliances DANGER Power must be turned off and disconnected from the power source whenever performing maintenance repair or cleaning the condensing unit If machine is still...

Page 12: ...ontroller The display will light up showing the temperature inside the unit Also the compressor and fan icons will flash for a period of three minutes After this delay the unit will start cooling Veri...

Page 13: ...to save the new set point Note The maximum value you can set in the controller is For refrigerators 5 C 40 F 3 If you wish decrease the value of the set point for a new temperature press the button DO...

Page 14: ...ters Type F parameters include the set point differential temperature monitoring interval interval between defrosts end defrost temperature dripping time alarm thresholds alarm bypass times etc See th...

Page 15: ...y the Parameter belongs to see the table below and the parameter table 5 Press the SET button to display the value of the parameter 6 Press UP DOWN until reaching the desired value 7 Press Set to temp...

Page 16: ...nless steel surface Failure to do so will result in spots and rust on the surface affected 6 1 CLEANING THE CONDENSER COIL DANGER Power must be turned off and disconnected from the power source whenev...

Page 17: ...ket and rip the bellows Gaskets can easily be replaced and do not require the use of tools or authorized service personnel To remove the gasket pull the gasket towards you To replace gasket press the...

Page 18: ...nit Do not store open containers with liquids inside the unit This will increase the amount condensation inside and outside of the unit and the evaporator coil will freeze up Do not store hot products...

Page 19: ...www fagorcommercial com Page19 MERCHANDSERS OPERATION AND SERVICE MANUAL Rev JUN 2015 7 WIRING DIAGRAMS FM 10...

Page 20: ...www fagorcommercial com Page20 MERCHANDSERS OPERATION AND SERVICE MANUAL Rev JUN 2015 FM 16 FMD 23...

Page 21: ...www fagorcommercial com Page21 MERCHANDSERS OPERATION AND SERVICE MANUAL Rev JUN 2015 FM 16F FMD 23F...

Page 22: ...the maximum level mark located on the internal wall of the unit f If FREEZER check that the temperature is not Celsius C g Check that the gasket is in good condition and door is sealed h Check that th...

Page 23: ...will be replaced and the replacement unit s will carry the same warranty period from the original unit s installation date original Warranty commencement date Additional Two Year Compressor Part Warr...

Page 24: ...d waived unless submitted by the User to Fagor within 30 days after the date the User discovered or should have discovered the claim In connection with all claims under this Warranty Fagor will have t...

Page 25: ...in deliveries that are beyond our control Damaged Merchandise Inspect shipment for any damage before accepting it If damaged open and inspect the contents with the carrier Any damage should be noted...

Page 26: ...fagorcommercial com Page26 MERCHANDSERS OPERATION AND SERVICE MANUAL Rev JUN 2015 Fagor Commercial Inc 13105NW 47thAve Miami Fl 33054 Tel 305 7790170 Fax 305 7790173 1 866 GO FAGOR www fagorcommercial...

Reviews: