background image

www.fagorcommercial.com

 

Page

25

 

 

 

MERCHANDSERS OPERATION AND SERVICE MANUAL/ Rev. JUN. 2015

 

Terms & Conditions 

 

 

Prices  &  Specifications:  Fagor  reserves  the  right  to  change  the  prices  and  specifications  of  the 
equipment and/or material without notice. Prices are FOB Fagor warehouses. All orders are subject 
to acceptance by Fagor Commercial, Inc.  

 

Terms: All orders are subject to credit approval. All Invoices not paid within the specified terms will 
be  subject  to  a  1.5%  per  month  delinquency  charge.  Buyer  agrees  to  pay  all  costs  of  collection 
including such attorney’s fees as may be allowed by law.  

 

Taxes: This price list does not include any Federal, State, City or Local taxes, which may apply and 
are subject thereto. 
 

 

Shipment:  Requested  carrier  will  be  used  upon  request.  Fagor  has  the  right  to  ship  via  any 
responsible carrier  if requested carrier is  unavailable.  Shipping charges are payable by consignee 
and  any  claims  arising  as  such  charges  shall  be  resolved  between  the  carrier  and  the  consignee. 
Shipping  dates  are  approximates.  Fagor  is  not  responsible  for  any  delays  in  deliveries  that  are 
beyond our control.  

 

Damaged  Merchandise:  Inspect  shipment  for  any  damage,  before  accepting  it.  If  damaged,  open 
and  inspect  the  contents  with  the  carrier.  Any  damage  should  be  noted  and  reported  on  the 
delivering carrier’s receipts. Fagor assumes nor responsibility for damages while in transit.   

 

Concealed Damage: If there is concealed damage to the equipment, notify the carrier immediately. 
Notification  should  be  made  verbally  as  well  as  in  written  form.  Request  an  inspection  by  the 
shipping company of the damaged equipment. Retain all crating material until inspection has been 
made.  
Cancellations  &  Returns:  Cancelled  orders  and  returned  merchandise  are  subject  to  a  25% 
restocking and handling charge. Written authorization is required for a return of any equipment. All 
equipment  returned  must  be  in  its  original  factory  crate;  freight  prepaid  and  must  be  in  the  same 
condition  as  originally  shipped  by  Fagor.  Returns  will  only  be  authorized  within  30  days  of  invoice 
date. 

 

Warranty: Register your product with Fagor Commercial to validate you warranty. Service calls must 
be 

made 

directly 

through 

Fagor 

service 

department. 

1-(866)-463-2467 

or 

e-mail: 

[email protected]

. 

 

 

*You may register your product online at http//:www.fagorcommercial.com

 

 

 

 

Summary of Contents for FMD-49

Page 1: ...MERCHANDISER REFRIGERATORS AND FREEZERS Manual for installation use and maintenance...

Page 2: ...TIONS 4 3 DIMENSIONS 6 4 INSTALLATION 9 4 1 UNCRATING 9 4 2 LOCATION 9 4 3 DATA PLATE 10 4 4 ELECTRICAL CONNECTIONS 11 4 5 SHELVING INSTALLATION 11 5 OPERATION 12 5 1 ELECTRONIC CONTROLLER 12 6 MAINTE...

Page 3: ...material until inspection has been made Contact the dealer through which you purchased the unit Check the compressor compartment thousing and visually inspect the refrigeration package Be sure lines...

Page 4: ...tion Line Super Heat BTU Ref Amount Ref Type Ship Weight Set Point Cut in FM 10 10 4 0 C 32 F 5 C 41 F 10 16 PSIG 7 C 13 F 1400 9 8 oz R 134a 203 FM 16 16 4 0 C 32 F 5 C 41 F 10 16 PSIG 7 C 13 F 1800...

Page 5: ...2P TT 15 amp 10 amp 14 AWG 14 AWG 14 AWG 14 AWG 12 AWG 14 AWG 12 AWG 14 AWG 12 AWG 14 AWG 10 AWG 12 AWG FM 16 1 4 115 220 5 8 3 4 5 15P 2P TT 15 amp 10 amp 14 AWG 14 AWG 14 AWG 14 AWG 12 AWG 14 AWG 12...

Page 6: ...www fagorcommercial com Page6 MERCHANDSERS OPERATION AND SERVICE MANUAL Rev JUN 2015 3 DIMENSIONS FM 10 FM 16...

Page 7: ...www fagorcommercial com Page7 MERCHANDSERS OPERATION AND SERVICE MANUAL Rev JUN 2015 FMD 23 FDM 49...

Page 8: ...www fagorcommercial com Page8 MERCHANDSERS OPERATION AND SERVICE MANUAL Rev JUN 2015 FMD 47 SD FMD 37 SD...

Page 9: ...ity is higher than 60 the door frames may sweat water This is not a malfunctioning of the unit WARNING The following actions will void your warranty Modification of power cord Connecting the unit to a...

Page 10: ...it The data plate is essential to identify the particular features of your machine and it is of great benefit to installers operators and maintenance personnel It is recommended that in the event the...

Page 11: ...ordance with NEC Article 422Appliances DANGER Power must be turned off and disconnected from the power source whenever performing maintenance repair or cleaning the condensing unit If machine is still...

Page 12: ...ontroller The display will light up showing the temperature inside the unit Also the compressor and fan icons will flash for a period of three minutes After this delay the unit will start cooling Veri...

Page 13: ...to save the new set point Note The maximum value you can set in the controller is For refrigerators 5 C 40 F 3 If you wish decrease the value of the set point for a new temperature press the button DO...

Page 14: ...ters Type F parameters include the set point differential temperature monitoring interval interval between defrosts end defrost temperature dripping time alarm thresholds alarm bypass times etc See th...

Page 15: ...y the Parameter belongs to see the table below and the parameter table 5 Press the SET button to display the value of the parameter 6 Press UP DOWN until reaching the desired value 7 Press Set to temp...

Page 16: ...nless steel surface Failure to do so will result in spots and rust on the surface affected 6 1 CLEANING THE CONDENSER COIL DANGER Power must be turned off and disconnected from the power source whenev...

Page 17: ...ket and rip the bellows Gaskets can easily be replaced and do not require the use of tools or authorized service personnel To remove the gasket pull the gasket towards you To replace gasket press the...

Page 18: ...nit Do not store open containers with liquids inside the unit This will increase the amount condensation inside and outside of the unit and the evaporator coil will freeze up Do not store hot products...

Page 19: ...www fagorcommercial com Page19 MERCHANDSERS OPERATION AND SERVICE MANUAL Rev JUN 2015 7 WIRING DIAGRAMS FM 10...

Page 20: ...www fagorcommercial com Page20 MERCHANDSERS OPERATION AND SERVICE MANUAL Rev JUN 2015 FM 16 FMD 23...

Page 21: ...www fagorcommercial com Page21 MERCHANDSERS OPERATION AND SERVICE MANUAL Rev JUN 2015 FM 16F FMD 23F...

Page 22: ...the maximum level mark located on the internal wall of the unit f If FREEZER check that the temperature is not Celsius C g Check that the gasket is in good condition and door is sealed h Check that th...

Page 23: ...will be replaced and the replacement unit s will carry the same warranty period from the original unit s installation date original Warranty commencement date Additional Two Year Compressor Part Warr...

Page 24: ...d waived unless submitted by the User to Fagor within 30 days after the date the User discovered or should have discovered the claim In connection with all claims under this Warranty Fagor will have t...

Page 25: ...in deliveries that are beyond our control Damaged Merchandise Inspect shipment for any damage before accepting it If damaged open and inspect the contents with the carrier Any damage should be noted...

Page 26: ...fagorcommercial com Page26 MERCHANDSERS OPERATION AND SERVICE MANUAL Rev JUN 2015 Fagor Commercial Inc 13105NW 47thAve Miami Fl 33054 Tel 305 7790170 Fax 305 7790173 1 866 GO FAGOR www fagorcommercial...

Reviews: