MERCHANDSERS OPERATION AND SERVICE MANUAL/ Rev. JUN. 2015

 

6

 

MAINTENANCE 

 

 

Stainless Steel Care and Cleaning 

 

Proper  cleaning  of  stainless  steel  requires  soft  cloths  or  plastic  scouring  pads.  Never  use  steel 
pads, wire brushes, or scrapers! 

 

Cleaning solutions need to be alkaline or non-chloride cleaners. Any cleaner containing chlorides 
will damage the protective film of the stainless steel. Chlorides are commonly found in hard water, 
salts, house hold and industrial cleaners. If a   cleaner containing chloride is used, be sure to rinse 
repeatedly and dry thoroughly up on completion. 

 

Stainless  steel m u s t   b e   c l e a n e d   e v e r y   d a y   with soap  and  water. Extreme  stains or grease 
should be cleaned with a non-abrasive cleaner and plastic scrub pad. When using a stainless steel 
chemical cleaner, make sure it is recommended for commercial applications.  

 

Never use an acid based cleaning solution! Many food products have an acidic content which can 
deteriorate the stainless steel finish. Be sure to clean ALL food products from any stainless steel 
surface. Failure to do so, will result in spots and rust on the surface affected. 

 

6.1

 

CLEANING THE CONDENSER COIL 

 
 
 
 

 

DANGER:  Power  must  be  turned  off  and  disconnected  from  the  power  source  whenever 
performing maintenance, repair or cleaning the condensing unit.

 

 

 

Disconnect machine. Remove front bottom panel and carefully slide out the condensing unit. 

 

The condenser coil requires regular cleaning. I t   i s   recommended every 30-60 days, depending on 
the accumulation of dust and grease. 

 

If the build upon the coil consists of only light dust and debris, the condenser coil can be cleaned 
with a simple brush. Heavier dust build up may require a vacuum or even compressed air to blow 
though the condenser coil. 

 

If heavy grease is present, there are de-greasing agents available for coils. The condenser 
coil  may  require  to  be  sprayed  with  de-greasing  agent  and  then  to  be  dried  with 
compressed  air. 

Be  sure  all  electrical  and  mechanical  parts  are  dry  before  turning  ON  the 

power.

 

 

Never  use  high  pressure  water  for  cleaning  t h e   c o n d e n s e r   c o i l .   Water  can  damage  the 
electrical components located near or at the condenser coil. Do not place filter material in front of 
condenser coil. This material blocks air-flow to the coil similar to having a dirty coil! 

Summary of Contents for FMD-49

Page 1: ...MERCHANDISER REFRIGERATORS AND FREEZERS Manual for installation use and maintenance...

Page 2: ...TIONS 4 3 DIMENSIONS 6 4 INSTALLATION 9 4 1 UNCRATING 9 4 2 LOCATION 9 4 3 DATA PLATE 10 4 4 ELECTRICAL CONNECTIONS 11 4 5 SHELVING INSTALLATION 11 5 OPERATION 12 5 1 ELECTRONIC CONTROLLER 12 6 MAINTE...

Page 3: ...material until inspection has been made Contact the dealer through which you purchased the unit Check the compressor compartment thousing and visually inspect the refrigeration package Be sure lines...

Page 4: ...tion Line Super Heat BTU Ref Amount Ref Type Ship Weight Set Point Cut in FM 10 10 4 0 C 32 F 5 C 41 F 10 16 PSIG 7 C 13 F 1400 9 8 oz R 134a 203 FM 16 16 4 0 C 32 F 5 C 41 F 10 16 PSIG 7 C 13 F 1800...

Page 5: ...2P TT 15 amp 10 amp 14 AWG 14 AWG 14 AWG 14 AWG 12 AWG 14 AWG 12 AWG 14 AWG 12 AWG 14 AWG 10 AWG 12 AWG FM 16 1 4 115 220 5 8 3 4 5 15P 2P TT 15 amp 10 amp 14 AWG 14 AWG 14 AWG 14 AWG 12 AWG 14 AWG 12...

Page 6: ...www fagorcommercial com Page6 MERCHANDSERS OPERATION AND SERVICE MANUAL Rev JUN 2015 3 DIMENSIONS FM 10 FM 16...

Page 7: ...www fagorcommercial com Page7 MERCHANDSERS OPERATION AND SERVICE MANUAL Rev JUN 2015 FMD 23 FDM 49...

Page 8: ...www fagorcommercial com Page8 MERCHANDSERS OPERATION AND SERVICE MANUAL Rev JUN 2015 FMD 47 SD FMD 37 SD...

Page 9: ...ity is higher than 60 the door frames may sweat water This is not a malfunctioning of the unit WARNING The following actions will void your warranty Modification of power cord Connecting the unit to a...

Page 10: ...it The data plate is essential to identify the particular features of your machine and it is of great benefit to installers operators and maintenance personnel It is recommended that in the event the...

Page 11: ...ordance with NEC Article 422Appliances DANGER Power must be turned off and disconnected from the power source whenever performing maintenance repair or cleaning the condensing unit If machine is still...

Page 12: ...ontroller The display will light up showing the temperature inside the unit Also the compressor and fan icons will flash for a period of three minutes After this delay the unit will start cooling Veri...

Page 13: ...to save the new set point Note The maximum value you can set in the controller is For refrigerators 5 C 40 F 3 If you wish decrease the value of the set point for a new temperature press the button DO...

Page 14: ...ters Type F parameters include the set point differential temperature monitoring interval interval between defrosts end defrost temperature dripping time alarm thresholds alarm bypass times etc See th...

Page 15: ...y the Parameter belongs to see the table below and the parameter table 5 Press the SET button to display the value of the parameter 6 Press UP DOWN until reaching the desired value 7 Press Set to temp...

Page 16: ...nless steel surface Failure to do so will result in spots and rust on the surface affected 6 1 CLEANING THE CONDENSER COIL DANGER Power must be turned off and disconnected from the power source whenev...

Page 17: ...ket and rip the bellows Gaskets can easily be replaced and do not require the use of tools or authorized service personnel To remove the gasket pull the gasket towards you To replace gasket press the...

Page 18: ...nit Do not store open containers with liquids inside the unit This will increase the amount condensation inside and outside of the unit and the evaporator coil will freeze up Do not store hot products...

Page 19: ...www fagorcommercial com Page19 MERCHANDSERS OPERATION AND SERVICE MANUAL Rev JUN 2015 7 WIRING DIAGRAMS FM 10...

Page 20: ...www fagorcommercial com Page20 MERCHANDSERS OPERATION AND SERVICE MANUAL Rev JUN 2015 FM 16 FMD 23...

Page 21: ...www fagorcommercial com Page21 MERCHANDSERS OPERATION AND SERVICE MANUAL Rev JUN 2015 FM 16F FMD 23F...

Page 22: ...the maximum level mark located on the internal wall of the unit f If FREEZER check that the temperature is not Celsius C g Check that the gasket is in good condition and door is sealed h Check that th...

Page 23: ...will be replaced and the replacement unit s will carry the same warranty period from the original unit s installation date original Warranty commencement date Additional Two Year Compressor Part Warr...

Page 24: ...d waived unless submitted by the User to Fagor within 30 days after the date the User discovered or should have discovered the claim In connection with all claims under this Warranty Fagor will have t...

Page 25: ...in deliveries that are beyond our control Damaged Merchandise Inspect shipment for any damage before accepting it If damaged open and inspect the contents with the carrier Any damage should be noted...

Page 26: ...fagorcommercial com Page26 MERCHANDSERS OPERATION AND SERVICE MANUAL Rev JUN 2015 Fagor Commercial Inc 13105NW 47thAve Miami Fl 33054 Tel 305 7790170 Fax 305 7790173 1 866 GO FAGOR www fagorcommercial...

Reviews: