10
The gas connection must be installed in
compliance with applicable regulations in the
country of installation.
•
Gas distributed via natural gas
pipework
For your safety, you can only choose from the
following 3 connection options:
— Connection with a rigid copper pipe
with
screw-on mechanical connectors (G1/2 gas
standard mark). Connect directly to the end of
the elbow fitted on the appliance.
— Connection with a flexible metal hose
(stainless steel)
with screw-on mechanical
connectors
(compliant with standard NF D 36-
121) with lifetime service guarantee
(Fig. A).
— Connection with a reinforced rubber
hose
with screw-on mechanical
connectors
(compliant with the NF D 36-103 standard)
with 10 year service life guarantee
(Fig. B).
Warning
If you have to change the direction
of the elbow fitted on the appliance
when connecting your hob’s gas supply:
①
①
Change the sealing washer.
②
②
Tighten the elbow nut but do not
exceed 17 N.m. torque.
GAS CONNECTION
• Preliminary comments
If your hob is installed above an oven or if the proximity of other heating elements risks
overheating the connection, you must insulate the cable in a rigid pipe.
If a flexible hose or pipe (in the case of butane gas) is used, it must contact a moving part of the
cabinet or traverse a location likely to become blocked.
•
;
;
@
@
;
;
Q
Q
Fig. A
Fig. B
1/ INSTALLING YOUR APPLIANCE