Digital Brushless
AC S
ervo
D
rive system - Ref. 1809
BCSD-91/116
• Manual Offset-adjustment of Servomotor Current Detection Signal.
Adjust the servomotor current detection signal manually in the following procedure.
Note:
The adjusting range of the servomotor current detection offset is -1024 to +1024.
4. Press the MODE key, the display will blinks for one second. The offset will be automatically adjusted.
5. Press the ENTER key to return to the utility function mode display Fn005.
Thus, the automatic offset-adjustment of the servomotor current detection signal is completed.
1. Press the MODE key to select the utility function mode.
2. Press the INC or DEC key to select the utility function number Fn006.
3. Press the ENTER key to enter into the manual adjustment of the servomotor current detection signal
mode.
4. Press the MODE key to switch between the phase U (o_CuA) and phase V (1_Cub) servomotor
current detection offset adjustment.
5. Hold the ENTER key for one second to display the phase V offset amount.
6. Press the INC or DEC key to adjust the offset.
7. Press the ENTER key for one second to return to the display in step 3 or 4.
8. Press the ENTER key to return to the utility function mode display Fn006.
Thus, the manual offset-adjustment of the servomotor current detection signal is completed.
Summary of Contents for BCSD-08AMA-01
Page 1: ...SYSTEM BCSD User manual Ref 1809...
Page 3: ...FAGOR AUTOMATION S COOP Brushless AC Servo Drives BCSD series Ref 1809...
Page 29: ...Digital Brushless AC Servo Drive system Ref 1809 BCSD 29 116 BCSD 30D 50D unit mm...
Page 38: ...BCSD 38 116 Digital Brushless AC Servo Drive system Ref 1809 Three phase 400V BCSD 10D 50D...
Page 114: ...BCSD 114 116 Digital Brushless AC Servo Drive system Ref 1809...
Page 115: ...Digital Brushless AC Servo Drive system Ref 1809 BCSD 115 116 User notes...
Page 116: ...BCSD 116 116 Digital Brushless AC Servo Drive system Ref 1809 User notes...
Page 117: ......