Digital Brushless
AC S
ervo
D
rive system - Ref. 1809
BCSD-89/116
5.2.5. Manual Adjustment of the Speed Reference Offset
Manual adjustment of the speed reference offset is used in the following cases.
• If a position loop is formed with the host controller and the error is zeroed when servolock is stopped.
• To deliberately set the offset to some value.
Use this mode to check the offset data that was set in the automatic adjustment mode of the speed/torque
reference offset.
This mode operates in the same way as the automatic adjustment mode, except that the amount of offset
is directly input during the adjustment.
The offset adjustment range and setting unit are as follows.
Note:
When the offset using in automatic adjustment exceeds manual adjustment range (-1024 ~ +1024),
manual adjustment will be invalid.
5. Press the MODE key for more than one second, the reference offset will be automatically adjusted.
6. Press ENTER key to return to the utility function mode display Fn003.
7. Thus, the speed reference offset automatic adjustment is completed.
Summary of Contents for BCSD-08AMA-01
Page 1: ...SYSTEM BCSD User manual Ref 1809...
Page 3: ...FAGOR AUTOMATION S COOP Brushless AC Servo Drives BCSD series Ref 1809...
Page 29: ...Digital Brushless AC Servo Drive system Ref 1809 BCSD 29 116 BCSD 30D 50D unit mm...
Page 38: ...BCSD 38 116 Digital Brushless AC Servo Drive system Ref 1809 Three phase 400V BCSD 10D 50D...
Page 114: ...BCSD 114 116 Digital Brushless AC Servo Drive system Ref 1809...
Page 115: ...Digital Brushless AC Servo Drive system Ref 1809 BCSD 115 116 User notes...
Page 116: ...BCSD 116 116 Digital Brushless AC Servo Drive system Ref 1809 User notes...